B6-CO/C3H8-100L | BACnet MSTP, Smart Sensor, Combination, Main: CO 0-250 ppm, Remote: CH3H8 0-100% LEL, 3 SPDT Relays, NEMA 4X | ACI
A/DLP-001-W-B-D-A-0-A-0P-S | Differential Low Pressure, 1 inWC, Bidirectional, LCD, 0.50% Accuracy, No Pitot Tube, 4-20mA Output, No Nist, Standard | ACI
FSIG-LSH-024 | PIEZOELECTRIC HORN SOUND MODULE 24VDC | ACI
FSIG-K8285237A | FLASHER | ACI
A/100-3W-S10-PB | 100 Ohm (Three Wires) RTD, Strap On, 10" Strap, Plastic Enclosure | ACI
A/100-3W-S10-GD | 100 Ohm (Three Wires) RTD, Strap On, 10" Strap, Galvanized Enclosure | ACI
A/RH3-1K-2W-RP2-20'-EH | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, ± 3% Accuracy, 1,000 Ohm RTD (Two Wires), 20' Plenum | ACI
A/RH3-1K-2W-RP2-10'-EH | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, ± 3% Accuracy, 1,000 Ohm RTD (Two Wires), 10' Plenum | ACI
A/CP-RS-A14-C5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint 10K to 0 Ohms, Cool/Warm Sticker | ACI
A/AN-RSO-A02-B4 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 0 to 20K Ohms, Override, 55-85 sticker | ACI
KW350-P1-D-S-RC-PC | POWER METER, BI-DIRECTIONAL, 3 CIRCUIT, ANSI 0.5 CLASS ACCURACY, SERIAL COMMUNICATION, BACNET MS/TP AND MODBUS RTU, ROGOWSKI COIL INPUTS, LCD DISPLAY, FACTORY INSTALLED NEMA 4X/IP66 ENCLOSURE | ACI
A/20K-PO-4"-20'CL2P | 20k Ohm Thermistor, Probe Only, 4", 20' Plenum Cable | ACI
A/20K-R2SO-A02-B4 | 20,000 Ohm Thermistor, Room (R2), Setpoint 0 to 20K Ohms, Override, 55-85 Sticker | ACI
A/3K-A-50’-PB | 3,000 Ohm Thermistor, Copper Averaging, 50', Plastic Enclosure | ACI
A/AN-RSO-A03-B4 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 0 to 10K Ohms, Override, 55-85 Sticker | ACI
A/1K-2W-FA-8'-4X | 1,000 Ohm (Two Wires) RTD, Flexible Cable Averaging, 8', NEMA 4X Enclosure | ACI
A/TTM1K-RA-36"-2-PB | Transmitter w/ 1,000 Ohm RTD (NIST Cert), Rigid Probe Averaging, 36", Plastic Enclosure, 2-10 VDC Output | ACI
A/AN-RSO-A01-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint, Override, 0 to 100K Ohms, Cool/Warm Sticker | ACI
A/AN-RSO-A20-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 6.19k to 26.19K Ohms, Override, Cool/Warm Sticker | ACI
A/DLP-020-W-B-D-B-0-A-0P-S | Differential Low Pressure, 20 inWC, Bidirectional, LCD, 0.25% Accuracy, No Pitot Tube, 4-20mA Output, No Nist, Standard | ACI
A/CSI-RSO-LCD-F-A29-C5 | 10,000 Ohm Thermistor (CSI), Room (R), Setpoint, Override, LCD, 7.87K to 27.87K Ohms, Cool/Warm Sticker | ACI
FSIG-LSL-024R | MODULE, LITESTAK, 24V, RED | ACI
FSIG-LSL-024G | MODULE, LITESTAK, 24V, GREEN | ACI
FSIG-LSL-024B | MODULE, LITESTAK, 24V, BLUE | ACI
FSIG-LSL-024A | MODULE, LITESTAK, 24V, AMBER | ACI
FSIG-LSBS | BASE, SURFACE MOUNT | ACI
FSIG-LSB-024-240 | BASE ASSY, LITESTAK | ACI
A/CSI-RS-LCD-F-A29-C5 | 10,000 Ohm Thermistor (CSI), Room (R), Setpoint, LCD, 7.87K to 27.87K Ohms, Cool/Warm Sticker | ACI
A/RH3-3K-D-4X | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 3,000 Ohm Thermistor, NEMA 4X Enclosure | ACI
A/AN-RS-A14-B4 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 10K to 0 Ohms, 55-85 Sticker | ACI
A/AN-RS-LCD-F-A02-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint, LCD, 0-20K, Cool/Warm, Deg F | ACI
A/1K-NI-IM-1"-4X | 1,000 Ohm Nickel RTD, Immersion, Machined Well, 1", NEMA 4X Enclosure | ACI
A/20K-R2SO-A24-G5 | 20,000 Ohm Thermistor, Room (R2), w/ Setpoint and Override, 55-85, RA, 9.5K-1K, Blue/Red sticker | ACI
TUC2-CP-F1-1H-ZP-X-X-X-X | 10,000 Ohm Thermistor (Type II), Setpoint, LCD | ACI
A/CP-RS-A10-C5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, 0 to 1K Ohms, Cool/Warm Sticker | ACI
A/RH1-AN-O-4X | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 1% Accuracy, 10,000 Ohm Thermistor (Type III), NEMA 4X Enclosure | ACI
A/AN-IM-8"-4X | 10,000 Ohm Thermistor (Type III), Immersion, Machined Well, 8", NEMA 4X Enclosure | ACI
A/RH2-TT1K-O-SUN-2 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 2% Accuracy, Transmitter w/ 1000 Ohm RTD, Sun Shield, 2-10VDC (Temp) | ACI
TUCH2-10F31EC0CL-310M1C0XX | LCD, RH3%, SET, O/R ,DEG F | ACI
A/RH2-AN-R2SO-A01-C5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy, 10K Ohm Thermistor (Type III), Setpoint:0-100K, Override, Cool/Warm sticker | ACI
A/DLP-005-W-U-D-B-0-A-3P-S | Differential Low Pressure, 5 inWC, Unidirectional, LCD, 0.25% Accuracy, No Pitot Tube, 4-20mA Output, 3 Point Nist, Standard | ACI
A/RH2-AN-R2SO-A38-D3 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room, ± 2% Accuracy, 10K Ohm Thermistor (Type III), Setpoint:20K-0, Override, Warm/Cool sticker | ACI
A/CP-R2SO-A04-B4 | 10,000 Ohm Thermistor (Type II), Room (R2), w/ Setpoint 1051.1 to 51.1, and Override, 55-85 sticker | ACI
A/CP-R-LCD-C | 10,000 Ohm Thermistor (Type II), Room (R), LCD, Deg C | ACI
A/CP-RS-RJ6-A01-C5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint 0 to 100K, RJ6, Cool/Warm sticker, Blank logo | ACI
A/TTM1K-A-50'-2-PB | Transmitter w/ 1,000 Ohm RTD (NIST Cert), Copper Averaging, 50', Plastic Enclosure, 2-10 VDC Output | ACI
A/DLP-003-W-U-D-A-0-C-0P-S | Differential Low Pressure, 3 inWC, Unidirectional, LCD, 0.50% Accuracy, No Pitot Tube, 0-10VDC Output, No Nist, Standard | ACI
A/TTM1K-HT-IM-6"-1-BB | Transmitter w/ 1,000 Ohm RTD (NIST Cert), High Temperature Immersion, Machined Well, 6" 316SS, NEMA 3R Enclosure, 1-5VDC Output | ACI
A/100-3W-D-18"-4X | 100 Ohm (Three Wires) RTD, Duct, 18", NEMA 4X Enclosure | ACI
A/TTM1K-HT-IM-4"-4-BB | Transmitter w/ 1,000 Ohm RTD (NIST Cert), High Temperature Immersion, Machined Well, 4" 316SS, NEMA 3R Enclosure, 4-20mA Output | ACI
A/10KS-S-4X | 10,000 Ohm Thermistor, Strap On, NEMA 4X Enclosure | ACI
A/10KS-R2S-A26-C5 | 10,000 Ohm Thermistor, Room (R2), Setpoint 886 to 1266, Cool/Warm Sticker | ACI
A/1K-3W-LT-IM-2.5-BB | 1,000 Ohm (Three Wires) RTD, Low Temperature Immersion, Machined Well, 2.5" 316SS, NEMA 3R Enclosure | ACI
A/100KS-D-6"-GD | 100,000 Ohm Thermistor, Duct, 6", Galvanized Enclosure | ACI
A/AN-RSO-RJ6-A01-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint, Override, Comm Jack (6 Pin/6 Conductor), 0 to 100K Ohms, Cool/Warm Sticker | ACI
A/DLP-7K5-P-U-N-A-1-A-0P-S | Differential Low Pressure, 7500 Pascals, Unidirectional, No Display, 0.50% Accuracy, w/ Pitot Tube, 4-20mA Output, No Nist, Standard | ACI
A/CP-PO-4"-20'CL2P | 10,000 Ohm Thermistor (Type II), Probe Only, 4", 20' Plenum Cable | ACI
A/DLP-1K6-P-U-N-A-1-A-0P-S | Differential Low Pressure, 1600 Pascals, Unidirectional, No Display, 0.50% Accuracy, w/ Pitot Tube, 4-20mA Output, No Nist, Standard | ACI
A/CP-RSO-A01-G5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, Override, 0 to 100K Ohms, Blue/Red Sticker | ACI
A/AN-RSO-A14-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 10K to 0 Ohms, Override, Cool/Warm Sticker | ACI
A/TT100-INW-8"-4-4X | Transmitter w/ 100 Ohm RTD, Immersion, No Well, 8", NEMA 4X Enclosure, 4-20mA Output | ACI
A/100-3W-INW-8"-4X | 100 Ohm (Three Wires) RTD, Immersion, No Well, 8", NEMA 4X Enclosure | ACI
A/RH3-CP-R2SO-A08-C5 | 1K-11K, DA, RH COOL/WARM | ACI
A/RH2-CP-R2S-A10-B4 | 1K, 0, RA, 55-85 | ACI
TUCH2-CPF11FZPSX-316XXXXXX | LCD, RH3%, SET, O/R, DEG F | ACI
TUCH2-ANF1XXXXSX-305XXXXXX | LCD, RH3%, O/R, DEG F | ACI
A/RH2-20K-RS-A24-C5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room, ± 2% Accuracy, 20K Ohm Thermistor, Setpoint: 9.5K-1K | ACI
BN2110-S10-PB | BACnet MS/TP, Modbus RTU, Temperature, Strap On, 2-10" Pipe, Plastic Enclosure | ACI
A/RH2-1K-3W-R | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 2% Accuracy, 1,000 Ohm (Three Wires) RTD | ACI
RT2630A-AC-30 | Wireless, Input Module (4 Analog & 4 Digital Inputs), 20K ohm Input, 24VAC, Trans Interval 30 sec. | ACI
A/TTM1K-RA-36"-4-PB | Transmitter w/ 1,000 Ohm RTD (NIST Cert), Rigid Probe Averaging, 36", Plastic Enclosure, 4-20mA Output | ACI
A/RH3-TTM1K-RP2-10'-4X-4 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, 10' Plenum, NEMA 4X Enclosure, ± 3% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output) | ACI
A/TTM1K-A-50'-4-PB | Transmitter w/ 1,000 Ohm RTD (NIST Cert), Copper Averaging, 50', Plastic Enclosure, 4-20mA Output | ACI
A/MLP2-100-P-B-B-B-3P | Differential Pressure, Panel Mount, 100 pascals, BiDirectional, +/- 0.25% FSO, 0-5VDC, 3 PT NIST | ACI
AFP VERSION #8 | Analog Input (0-5VDC), Floating Point Output (46 sec), Version #6, (240, 600s Selectable) | ACI
A/TT100-HT-D-8"-1-GD | Transmitter w/ 100 Ohm RTD, High Temperature Duct, 8" 316SS, Galvanized Enclosure, 1-5VDC Output | ACI
A/RH1-CP-R2L | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 1% Accuracy, 10,000 Ohm Thermistor (Type II), Custom Logo | ACI
A/MLP2-002-W-U-B-A-0P | Differential Pressure, Panel Mount, 2.00 inWC, UniDirectional, +/- 0.25% FSO, 4-20mA | ACI
A/RH2-AN-R2SO-A01-G5 | 100K, 0, DA, BLUE/RED | ACI
A/TTM100-BP-4-GD-10'CL2P | Transmitter w/ 100 Ohm RTD (NIST Cert), Bullet Probe, 1", 10' Plenum Cable, Galvanized Enclosure, 4-20mA Output | ACI
A/TTM1K-RA-24"-4-PB | Transmitter w/ 1,000 Ohm RTD (NIST Cert), Rigid Probe Averaging, 24", Plastic Enclosure, 4-20mA Output | ACI
QTS-17191X-S000000-ACETONE | Expl Proof Sensor, Acetone, 0-100% LEL, 3-wire 4-20mA Output | ACI
FSIG-SLMDG2 | Protective Dome for Deep Mounting Base and SLM500x Series Horn and Strobe | ACI
A/RH3-1K-NI-R2S-A09-G5 | 2K, 0, RA | ACI
SCREWDRIVER INSERT BIT | FOR HEX TAMPER RESISTAND 5/64 | ACI
Q8-CL2-5P-R-X | Expl Proof, Smart Sensor, Chlorine, 0-5 ppm, 3 SPDT Relays, NEMA 4X, 4-20mA, 2-10V, or Modbus RTU W/Remote Sensor | ACI
DT2630A-04-300 | Wireless, Temp, Duct, 4", Trans Interval 300 sec | ACI
A/100-3W-R-EXPL | 100 Ohm (Three Wires) RTD, Hazardous, Room (R), 2" | ACI
A/RH3-CP-RSO-A03-C5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 3% Accuracy, 10K Ohm Thermistor (Type II), Setpoint:0-10K, Override | ACI
A/RH2-AN-R2S-A01-G5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy, 10K Ohm Thermistor (Type III), Setpoint:0-100K | ACI
A/RH3-AN-R2SO-A02-G5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 3% Accuracy, 10K Ohm Thermistor (Type III), Setpoint 0-20K, Override, Blue/Red sticker | ACI
A/TT1K-HT-INW-4"-1-GD | Transmitter w/ 1,000 Ohm RTD, High Temperature Immersion, No Well, 4", Galvanized Enclosure, 1-5VDC Output | ACI
A/TT1K-RS-A16-4-RES-C5 | Transmitter w/ 1,000 Ohm RTD, Room (R), Setpoint 5K, 4-20mA Output, RES | ACI
A/RH2-10KS-R2SO-A26-G5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy, 10K Ohm Thermistor, w/ Setpoint 866-1266, & Override, Blue/Red sticker | ACI
A/RH1-TT1K-D-BB-2 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 1% Accuracy, Transmitter w/ 1,000 Ohm RTD, NEMA 3R (2G) Enclosure, 2-10 VDC (Temp) | ACI
A/AN-BC-O-4X | 10,000 Ohm Thermistor w/11K Shunt, Outside Air, NEMA 4X Enclosure | ACI
A/0.25" SNUBBER WTR | Snubber (0.25"), 1/4"NPT, 316SS, Water / fluid | ACI
A/TT100-LTS-1-GD-10' | Transmitter w/ 100 Ohm RTD, 2" Freezer Probe 316SS, NEMA 4X Enclosure, 10', 1-5VDC Output | ACI
A/RH3-TT1K-D-4X-1 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, Transmitter w/ 1,000 Ohm RTD, NEMA 4X Enclosure, 1-5VDC (Temp) | ACI
A/RH3-AN-BC-D | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 10,000 Ohm Thermistor w/11K Shunt, Euro Enclosure | ACI
A/RH3-1K-3W-R | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 3% Accuracy, 1,000 Ohm RTD (Three Wires) | ACI
A/TTM100-O-4-BB | Transmitter w/ 100 Ohm RTD (NIST Cert), Outside Air, NEMA 3R Enclosure, 4-20mA Output | ACI
A/RH3-CP-R2O | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 3% Accuracy, 10K Ohm Thermistor (Type II), w/ Override | ACI
RN (10K-10.5K) | Resistor Network (10K to 10.5K Ohms) | ACI
A/RH3-D-4X | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, NEMA 4X Enclosure | ACI
A/TTM100-I-6"-4-BB | Transmitter w/ 100 Ohm RTD (NIST Cert), Immersion, Welded Well, 6", NEMA 3R Enclosure, 4-20mA Output | ACI
A/TT1K-RSO-4-LCD-C5 | Transmitter w/ 1,000 Ohm RTD, Room (R) with Setpoint and Override, 4-20mA Output, LCD, C/W | ACI
A/TT1K-RSO-4-C5 | Transmitter w/ 1,000 Ohm RTD, Room (R) with Setpoint and Override, 4-20mA Output, C/W | ACI
A/TT1K-RSO-2-C5 | Transmitter w/ 1,000 Ohm RTD, Room (R) with Setpoint and Override, 2-10VDC Output, C/W | ACI
A/TT1K-RS-4 | Transmitter w/ 1,000 Ohm RTD, Room (R) with Setpoint, 4-20mA Output | ACI
A/TT1K-RS-4-C5 | Transmitter w/ 1,000 Ohm RTD, Room (R) with Setpoint, 4-20mA Output, C/W | ACI
A/TT100-D-4"-4-BB | Transmitter w/ 100 Ohm RTD, Duct, 4", NEMA 3R Enclosure, 4-20mA Output | ACI
A/TT100-RSO-4-C5 | Transmitter w/ 100 Ohm RTD, Room (R) w/ Setpoint and Override, 4-20mA Output, C/W | ACI
A/TT100-RO-4 | Transmitter w/ 100 Ohm RTD, Room (R) with Override, 4-20mA Output | ACI
A/TT100-RS-1-LCD-C5 | Transmitter w/ 100 Ohm RTD, Room (R) with Setpoint, 1-5VDC Output, LCD, C/W | ACI
A/CP-RS-A04-C5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, 1051.1 to 51.1 Ohms, Cool/Warm Sticker | ACI
A/RH2-CP-R2SO-A14-G5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy, 10K Ohm Thermistor (Type II), Setpoint:10K-0, Override, Blue/Red sticker | ACI
A/AN-RS-LCD-F-A01-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint, LCD, 0-100K, Cool/Warm, Deg F | ACI
A/TT100-LT-I-6"-4-BB | Transmitter w/ 100 Ohm RTD, Low Temperature Immersion, Welded Well, 6" 316SS, NEMA 3R Enclosure, 4-20mA Output | ACI
A/AN-R2S-RJ6-A16-C5 | 10,000 Ohm Thermistor (Type III), Room (R2), Setpoint 0-5K, RJ6, Cool/Warm sticker | ACI
A/20K-RS-A14-D3 | 20,000 Ohm Thermistor, Room (R), Setpoint 10K to 0 Ohms, Override, Warm/Cool Sticker | ACI
A/RH3-RP2-6'-EH | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, ± 3% Accuracy, 6' Plenum | ACI
A/1K-NI-RO | 1,000 Ohm Nickel RTD, Room (R), Override, Blank logo | ACI
A/DLP-050-P-B-N-B-0-A-3P-S | Differential Low Pressure, 50 Pascals, Bidirectional, No Display, 0.25% Accuracy, No Pitot Tube, 4-20mA Output, 3 Point Nist, Standard | ACI
A/DLP-050-P-B-N-B-0-A-0P-S | Differential Low Pressure, 50 Pascals, Bidirectional, No Display, 0.25% Accuracy, No Pitot Tube, 4-20mA Output, No Nist, Standard | ACI
A/AN-RS-LCD-F-A17-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint, LCD, 4.99K to 24.99K, Cool/Warm, Deg F | ACI
A/20K-R2SO-A39-C5 | 20,000 Ohm Thermistor, Room (R2), Setpoint 5K to 0 Ohms, Override, Cool/Warm Sticker | ACI
A/TTM1K-S-1-4X | Transmitter w/ 1,000 Ohm RTD (NIST Cert), Strap On, NEMA 4X Enclosure, 1-5VDC Output | ACI
A/TT100-R-1-EXPL | Transmitter w/ 100 Ohm RTD, Hazardous, Room (R), 2", 1-5VDC Output | ACI
A/DLP-003-W-U-N-A-0-A-0P-S | Differential Low Pressure, 3 inWC, Unidirectional, No Display, 0.50% Accuracy, No Pitot Tube, 4-20mA Output, No Nist, Standard | ACI
A/AN-R2S-A16-C5 | 10,000 Ohm Thermistor (Type III), Room (R2), Setpoint 0 to 5K Ohms, Cool/Warm Sticker | ACI
A/AN-R2SO-A38-D3 | 10,000 Ohm Thermistor (Type III), Room (R2), Setpoint 20K to 0 Ohms, Override, Warm/Cool Sticker | ACI
A/DLP-750-P-B-D-B-3-A-0P-S | Differential Low Pressure, 750 Pascals, Bidirectional, LCD, 0.25% Accuracy, w/ Pitot Tube and Din Rail, 4-20mA Output, No Nist, Standard | ACI
A/AN-R-LCD-C | 10,000 Ohm Thermistor (Type III), Room (R), LCD, C | ACI
A/CP-RS-A10-D3 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, 0 to 1K Ohms, Warm/Cool Sticker | ACI
A/1.8K-A-8'-BB | 1,800 Ohm Thermistor, Copper Averaging, 8', NEMA 3R Enclosure | ACI
A/DLP-500-P-U-D-A-0-A-0P-S | Differential Low Pressure, 500 Pascal, Unidirectional, LCD Display, +/-0.5% Accuracy, 0-10VDC Output, 4-20mA output, No Nist, Standard | ACI
A/DLP-2D5-W-U-N-A-0-A-0P | Differential Low Pressure, 2.5 inWC, Unidirectional, No Display, 0.50% Accuracy, No Pitot Tube, 4-20mA Output, No Nist, Standard | ACI
A/MLP2-D25-W-B-B-C-3P | Differential Pressure, Panel Mount, 0.25 inWC, BiDirectional, +/- 0.25% FSO, 0-10VDC, 3 PT NIST | ACI
A/CP-RS-LCD-F-A03-C5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, LCD, 0-10K, Cool/Warm, Deg F | ACI
A/TT1K-I-6”-2-PB | Transmitter w/ 1,000 Ohm RTD, Immersion, Welded Well, 6", Plastic Enclosure, 2-10VDC Output | ACI
A/TT1K-RA-36"-4-4X | Transmitter w/ 1,000 Ohm RTD, Rigid Probe Averaging, 36", NEMA 4X Enclosure, 4-20mA Output | ACI
A/1K-NI-R2S-A09-G5 | 1,000 Ohm Nickel RTD, Room (R2), Setpoint 0 to 2K Ohms, Blue/Red Sticker | ACI
A/10KS-R2O | 10,000 Ohm Thermistor, Room (R2), Override | ACI
A/CP-R2SO-A03-B4 | 10,000 Ohm Thermistor (Type II), Room (R2), Setpoint, Override, 0 to 10K Ohms, 55-85 Sticker | ACI
A/TTM100-D-4"-4-4X | Transmitter w/ 100 Ohm RTD (NIST Cert), Duct, 4", NEMA 4X Enclosure, 4-20mA Output | ACI
A/1K-2W-RS-A09-C5 | 1,000 Ohm (Two Wires) RTD, Room (R), Setpoint, 0 to 2K Ohms, Cool/Warm Sticker | ACI
A/MLP2-002-W-U-B-A-3P | Differential Pressure, Panel Mount, 2.00 inWC, UniDirectional, +/- 0.25% FSO, 4-20mA, 3 PT NIST | ACI
A/10KS-RS-RJ6-A26-C5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, Override, 866 to 1266 Ohms, RJ6, Cool/Warm Sticker | ACI
A/CP-R2S-A14-C5 | 10,000 Ohm Thermistor (Type II), Room (R2), Setpoint, 10K to 0 Ohms, Cool/Warm Sticker | ACI
A/AN-BC-RS-RJ6-A03-C5 | 10,000 Ohm Thermistor w/11K Shunt, Room (R), Setpoint 0 to 10K Ohms, Comm Jack (6 Pin/6 Conductor), Cool/Warm Sticker | ACI
A/AN-R2SO-A16-B4 | 10,000 Ohm Thermistor (Type III), Room (R2), Setpoint 0 to 5K Ohms, Override, 55-85 Sticker | ACI
A/AN-RS-A02-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 0 to 20K Ohms, Cool/Warm Sticker, Blank logo | ACI
A/1K-2W-A-24’-PB-NIST | 1,000 Ohm (Two Wires) RTD, Copper Averaging, 24', Plastic Enclosure, NIST Cert | ACI
LD2100 | Distance-Read Leak Detection Controller, LED Display, Web Enabled, LC-KIT | ACI
A/3K-RSO-LCD-F-A07-C5 | 3,000 Ohm Thermistor, Room (R), Setpoint 10 to 30k, Override, LCD, Cool/Warm | ACI
A/RH2-CP-RSO-A01-C6 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 2% Accuracy, 10,000 Ohm Thermistor (Type II), w/ Setpoint (0-100K) and Override, Cooler/Warmer | ACI
A/DLP-003-W-U-D-A-0-B-0P-S | Differential Low Pressure, 3 inWC, Unidirectional, LCD, 0.50% Accuracy, No Pitot Tube, 0-5VDC Output, No Nist, Standard | ACI
A/RH2-TTM100-R-4 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 2% Accuracy, Transmitter w/ 100 Ohm RTD (NIST CERT), 4-20mA (Temp Output) | ACI
A/3K-RSO-A11-C5 | 3,000 Ohm Thermistor, Room (R), w/ Setpoint 2.05K to 3.05K and Override, COOL/WARM | ACI
A/1K-NI-R2S-A09-C6 | 1,000 Ohm Nickel RTD, Room (R2), Setpoint 0 to 2K Ohms, Cooler/Warmer Sticker | ACI
A/3K-D-6"-BB | 3,000 Ohm Thermistor, Duct, 6", NEMA 3R Enclosure | ACI
A/TT100-IM-6"-1-PB | Transmitter w/ 100 Ohm RTD, Immersion, Machined Well, 6", Plastic Enclosure, 1-5VDC Output | ACI
A/MLP2-004-W-B-B-A-0P | Differential Pressure, Panel Mount, 4.00 inWC, BiDirectional, +/- 0.25% FSO, 4-20mA | ACI
A/AN-RO-LCD-F | 10,000 Ohm Thermsitor (Type III), Room (R), w/ Override, LCD | ACI
A/10KS-RS-A26-C5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, Override, 866 to 1266 Ohms, DA, Cool/Warm Sticker | ACI
A/CP-RS-A01-G5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, 0 to 100K Ohms, Blue/Red Sticker | ACI
TUC2-CP-F1-1F-B0-S-X-X-X | 10,000 Ohm Thermistor (Type II), Setpoint, w/ Override, LCD | ACI
A/1K-3W-D-12"-BB | 1,000 Ohm (Three Wires) RTD, Duct, 12", NEMA 3R Enclosure | ACI
A/CP-R2SO-A02-G5 | 10,000 Ohm Thermistor (Type II), Room (R2), Setpoint, Override, 0 to 20K Ohms, Blue/Red (R2 Enclosure) | ACI
A/CP-RS-A03-G5 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, 0 to 10K Ohms, Blue/Red Sticker | ACI
A/TTM100-I-4"-1-GD | Transmitter w/ 100 Ohm RTD (NIST Cert), Immersion, Welded Well, 4", Galvanized Enclosure, 1-5VDC Output | ACI
A/1K-2W-R2SO-A28-G5 | 1,000 Ohm (Two Wires) RTD, Room (R), Room (R), Setpoint, Override, 806 to 1206 Ohms, Blue/Red Sticker | ACI
A/1K-2W-IM-6"-BB | 1,000 Ohm (Two Wires) RTD, Immersion, Machined Well, 6", NEMA 3R Enclosure | ACI
A/CP-R2SO-A10-C5 | 10,000 Ohm Thermistor (Type II), Room (R2), Setpoint, Override, 0 to 1K Ohms, Cool/Warm Sticker | ACI
A/1K-2W-R2S-A03-C5 | 1,000 Ohm (Two Wires) RTD, Room (R2), Setpoint, 0 to 10K Ohms, Cool/Warm Sticker | ACI
A/1K-2W-R2SO-A03-C5 | 1,000 Ohm (Two Wires) RTD, Room (R2), Setpoint, Override, 0 to 10K Ohms, Cool/Warm Sticker | ACI
TUCH2-CPF11FB0XX-205XXXXXX | LCD, RH2%, SET, DEG F | ACI
TUCH2-CPF11FG0XX-216XXXXXX | LCD, RH2%, SET, DEG F | ACI
A/RH1-TTM1K-O-3.25”-4X-4 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air (3.25" SS), NEMA 4X Enclosure, ± 1% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output) | ACI
A/CP-R2SO-232-A11-C5 | 10,000 Ohm Thermistor (Type II), Room (R2), w/ Setpoint and Override, RS232 | ACI
A/RH3-CP-RS-A04-C5 | Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 3% Accuracy, 10,000 Ohm Thermistor (Type II), w/ Setpoint | ACI
A/TB-2.0-XXA-BO | Thermal Buffer, Empty 2 oz Nalgene Bottle, 1 Sensing Point, Rated to -100C | ACI
A/AN-R2SO-A35-C5 | 10,000 Ohm Thermistor (Type III), Room (R2), Setpoint 200 to 2.2K Ohms, Override, Cool/Warm Sticker | ACI
TUCH2-10F3-1EC0CX210N4C0-XX | LCD, RH 2%, SET, O/R, DEG F | ACI
A/20K-RS-A14-C5 | 20,000 Ohm Thermistor, Room (R), Setpoint 10K to 0 Ohms, Cool/Warm Sticker | ACI
A/AN-PO-2"-20'CL2P | 10,000 Ohm Thermistor (Type III), Probe Only, 2", 20' Plenum Cable | ACI
A/1K-NI-IM-2.5"-PB | 1,000 Ohm Nickel RTD, Immersion, Machined Well, 2.5", Plastic Enclosure | ACI
A/CP-RS-A34-C6 | 10,000 Ohm Thermistor (Type II), Room (R), Setpoint, 20K to 21K Ohms, Cooler/Warmer Sticker | ACI
A/AN-RS-RJ4-A03-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 0 to 10K Ohms, Override, RJ4, Cool/Warm Sticker | ACI
A/AN-RS-A01-C5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 0 to 100K Ohms, Cool/Warm Sticker | ACI
A/AN-R-RJ4 | ROOM, RJ4 | ACI
A/CP-RSO-A04-A0 | 10,000 Ohm Thermistor (Type II), Room (R), w/ Setpoint and Override | ACI
A/20K-RSO-A24-B4 | 20,000 Ohm Thermistor, Room (R), w/ Setpoint and Override | ACI
A/AN-RSO-A02-A1 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 0 to 20K Ohms, Override, - to + Sticker | ACI
A/CP-RO-RJ6 | 10,000 Ohm Thermistor (Type II), Room (R), Override, Comm Jack (6 Pin/6 Conductor) | ACI
A/DLP-003-W-B-N-B-1-C-3P-S | Differential Low Pressure, 3 W, Bidirectional, No Display, 0.25% Accuracy, w/ Pitot Tube, 0-10VDC Output, 3 Point Nist, Standard | ACI
A/DLP-D25-W-B-D-B-1-C-3P-S | Differential Low Pressure, 0.25 W, Bidirectional, LCD, 0.25% Accuracy, w/ Pitot Tube, 0-10 VDC Output, 3 Point Nist, Standard | ACI
A/AN-RS-A03-G5 | 10,000 Ohm Thermistor (Type III), Room (R), Setpoint 0 to 10K Ohms, BLUE/RED Sticker | ACI
A/TTM1K-LTS-1-4X-10' | Transmitter w/ 1,000 Ohm RTD (NIST Cert), 2" Freezer Probe 316SS, NEMA 4X Enclosure, 10', 1-5VDC Output | ACI