Collections
Air Diffusers, Grilles & Register
Schedule 40 PVC Plastic Fittings
Schedule 80 PVC Plastic Fittings
Schedule 80 CPVC Plastic Fittings
Plastic PVC Schedule 80 Fittings
Plastic PVC Schedule 80 Nipples
Drain Waste Vent DWV Plastic Fittings
Pressure & Flow Control Valves
Stainless Steel Mini Ball Valves
Chrome Plated Brass Mini Ball Valves
Bulkhead/Anchor/Frame Couplings
Double Compression Brass Fittings
Check and Anti Siphon Brass Valves
1/4 Industrial Interchange Pneumatic Fittings
Pressure Washer Pneumatic Fittings
Bulkhead Steel 37 Degree JIC Flare
Straights Steel 37 Degree JIC Flare
Shapes Steel 37 Degree JIC Flare
Stainless Steel Flareless Bite Fittings
Stainless Steel Push On Hose Barb
3000# 316 Stainless Steel Fittings
Brands
Products
CFS2-DNBPN-80 | PVC cable | SPDT | 10(8)A 250V~ | 80 ft ( 24.38 m) cable | Dwyer
CFS2-ONBPN-20 | PVC cable | SPST | NO | 10(8)A 250V~ | 20 ft ( 6.10 m) cable | Dwyer
DBLM3040 | Mini-bin dry bulk level monitor | 110 VAC power supply. | Dwyer
CDTA-2N000 | CO2/Temperature/Humidity, Modbus & BACNet, 2000 ppm | Dwyer
CCT40-102 | Split core Selectable 10/20/50 A Range, Self-powered, 0-5 V | Dwyer
CFS2-DNBPN-20 | PVC cable | SPDT | 10(8)A 250V~ | 20 ft ( 6.10 m) cable | Dwyer
BTLS32551 | Bimetal thermometer | 2-1/2" stem | range 0 to 240°F. | Dwyer
CCT40-202 | Solid core Selectable 10/20/50 A Range, Self-powered, 0-5 V | Dwyer
CCT50-200 | Solid core Selectable 100/150/200 A Range, 15-42 VDC, loop powered, 4-20 mA | Dwyer
BTT-N00-4 | North American wall mount temperature transmitter with 0 to 10 VDC output | Dwyer
BTPM260101 | Panel mount bimetal stem thermometer | range 0 to 200°F | 6" stem. | Dwyer
BTT-D08-2 | Duct Mount Temperature Transmitter with 0 to 10 V output | 8" probe | Dwyer
BTM36010D | Maximum/minimum bimetal thermometer | range 0 to 200°F | 6" stem. | Dwyer
BBV-21 | 5-valve manifold with side mounted vent valves. | Dwyer
BTM34010D | Maximum/minimum bimetal thermometer | range 0 to 200°F | 4" stem. | Dwyer
BPS-005 | Low Cost DC Power Supply | Dwyer
BBV-22 | 5-valve manifold with top mounted vent valves. | Dwyer
BBV-1F | Flanged 3-valve block manifold. | Dwyer
A-SVT-V | Replacement pilot valve assembly for SVT Series. | Dwyer
AVFS-2 | Thermo air flow switch | 24 VDC. | Dwyer
ASG | Analog signal generator. | Dwyer
A-700-4 | Power supply ( 4.8 A). | Dwyer
A-464 | Flush mount kit for Magnehelic® gages (Magnehelic® sold separately) | Dwyer
A3004 | Pressure switch/gage | range 0-4.0" w.c. | Dwyer
A6-453221 | Pressure switch | set point range 8-13 ±2 psi (0.55-0.90 ±0.18 bar). | Dwyer
A-286 | 4-1/2" Gage panel mounting flange | Dwyer
A-301-C | Static pressure tip | for 1/4" metal tubing connection with 12" insertion depth. | Dwyer
A3010 | Pressure switch/gage | range 0-10" w.c. | Dwyer
A3006 | Pressure switch/gage | range 0-6.0" w.c. | Dwyer
A3003 | Pressure switch/gage | range 0-3.0" w.c. | Dwyer
A3015 | Pressure switch/gage | range 0-15" w.c. | Dwyer
A-103 | 1 pt bottle of red gage fluid | .826 sp. gr. | Dwyer
477AV-4 | Digital manometer | range 0-10.00 psi | air velocity/flow modes. | Dwyer
A-2003-1 | Nylon elbow | 1/8" MNPT x 1/4" HB. | Dwyer
A-257 | Pressure snubber | 316 SS | 1/4" male/female BSPP | Dwyer
A3002 | Pressure switch/gage | range 0-2.0" w.c. | Dwyer
A3000-00N | Pressure switch/gage | range .05 to .20" w.c. | Dwyer
A-104 | 1 qt bottle of red gage fluid | .826 sp. gr. | Dwyer
A-2016-1 | Nylon hose barb tee | 1/4" HB(1) x 1/4" HB(2&3). | Dwyer
647-3 | Wet/wet differential pressure transmitter | range 0-5" w.c. | Dwyer
A-120 | 1 oz dispenser bottle of violet gage fluid | 1.000 sp. gr. | Dwyer
685-01-V | Differential pressure transmitter | 0-2" wc | 0-10 V output | Dwyer
673-3 | Pressure transmitter | range 0-5 psi. | Dwyer
616W-2-LCD | Differential pressure transmitter | range 0-6" w.c. | max. pressure 10 psig. | Dwyer
668D-09-1 | Compact differential pressure transmitter | 4 to 20 mA | 0 to 50" w.c. | Dwyer
668-4 | Differential pressure transmitter | range 0-2.5" w.c. | Dwyer
668-18 | Differential pressure transmitter | bi-directional | range 0 to ±50" w.c. | Dwyer
668D-05-1 | Compact differential pressure transmitter | 4 to 20 mA | 0 to 2.5" w.c. | Dwyer
659RTD-1 | Push-button temperature transmitter | 3-wire RTD Pt100 ohm input. | Dwyer
659TC-1 | Push-button temperature transmitter | thermocouple (type J | K | T) input. | Dwyer
629HLP-04-P4-S1 | Differential pressure transmitter | 0 to 4 bar | 1/4" Female BSPT | 4-20mA | Dwyer
616W-6-LCD | Differential pressure transmitter | range 0-100" w.c. | max. pressure 15 psig. | Dwyer
668-11 | Differential pressure transmitter | bi-directional | range 0 to ±0.25" w.c. | Dwyer
648B-15 | Zero center range -1-0-1" w.c. | Dwyer
636-3 | Fixed range pressure transmitter | range 0-300 psi (0-20 bar). | Dwyer
641-12 | Air velocity transmitter | 12" (304.8 mm) probe length. | Dwyer
4380 | Process signal converter/isolator | Dwyer
616D-2 | Differential pressure transmitter | range 0-6" w.c. | max. pressure 10 psig. | Dwyer
610-00C-BNV | Low differential pressure transmitter | range ±0.05" w.c. | Dwyer
2813-WP | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output. | Dwyer
477AV-0 | Digital manometer | range 0-10.00" w.c. | air velocity/flow modes. | Dwyer
477AV-2 | Digital manometer | range 0-40.00" w.c. | air velocity/flow modes. | Dwyer
477AV-000 | Digital manometer | range 0-1.00" w.c. | air velocity/flow modes. | Dwyer
490A-6 | Wet/Wet handheld digital manometer | 0 to 200 psi (0 to 1379 kPa) | Dwyer
4210 | Differential pressure gage | range 0-10 psi. | Dwyer
477B-4 | Handheld digital manometer | 0 to 10 psi (0 to 68.95 kPa) | Dwyer
477-00T-AV | Air velocity kit | 0-4" w.c. | Dwyer
2015D | Differential pressure gage | range 0-15" w.c. & 0-3.7 kPa. | Dwyer
2-5040-NPT | Differential pressure gage | range 0-40" w.c. | 1/8" male NPT connection. | Dwyer
2330 | Differential pressure gage | range 15-0-15" w.c. | minor divisions 1.0. | Dwyer
2-5005-NPT | Differential pressure gage | range 0-5.0" w.c. | 1/8" male NPT connection. | Dwyer
32A020 | Temperature controller/process | no alarm | (1) 5 VDC output. | Dwyer
32DZ1122 | Temperature/process controller | thermocouple inputs | 5 VDC outputs. | Dwyer
32B-33-LV | 1/32 DIN temperature/process controller | relay outputs 1 and 2 | low voltage | Dwyer
2-5001-NPT | Differential pressure gage | range 0-1.0" w.c. | 1/8" male NPT connection. | Dwyer
2-5002-NPT | Differential pressure gage | range 0-2.0" w.c. | 1/8" male NPT connection. | Dwyer
2150 | Differential pressure gage | range 0-150" w.c. | minor divisions 5.0. | Dwyer
3015MRS | Pressure switch/gage | range 0-15" w.c. | .50 minor divisions. | Dwyer
2320 | Differential pressure gage | range 10-0-10" w.c. | minor divisions .50. | Dwyer
201-WT-7810-C1-60 | Chamber type level control | side mounted | SPDT snap switch. | Dwyer
2040 | Differential pressure gage | range 0-40" w.c. | minor divisions 1.0. | Dwyer
160S-18PM | Permanent mount "S" type stainless steel Pitot tube | 18" insertion length. | Dwyer
1996-5 | Gas pressure switch | range 1.4-5.5" w.c. | Dwyer
2000-20KPA | Differential pressure gage | range 0-20 kPa | minor divisions .50. | Dwyer
166-12 | Pocket size Pitot tube | 1/8" dia. | 12" insertion length | 3" tip. | Dwyer
160F | Straight stainless steel pitot tube | 18" | Dwyer
15123 | Temperature controller | RTD (DIN) input | relay output | with alarm. | Dwyer
1223-16-W/M | U-tube manometer | range 8-0-8" w.c. | Dwyer
123-7000-153 | Water level control | cast iron chamber | SPDT snap switch. | Dwyer
1211-30 | Manometer | range 15-0-15 | 15 oz water or mercury required. | Dwyer
1221-M400-D | U-tube manometer | range 200-0-200 mm w.c. | Dwyer
1222-12-D | U-tube manometer | range 6-0-6" w.c. | Dwyer
1222-12-W/M | U-tube manometer | range 6-0-6" w.c. | Dwyer
A-IEF-DSP | Series IEF Insertion Electromagnetic Flowmeter IEF/IEFB field set-up display | Dwyer
1211-100 | Manometer | range 50-0-50 | 18-1/2 oz water or mercury required. | Dwyer
1221-16-W/M | U-tube manometer | range 8-0-8" w.c. | Dwyer
1211-24 | Manometer | range 12-0-12 | 12-1/2 oz water or mercury required. | Dwyer
953-6333RP | RP,CASING,CI/FI3013D,125# BRZ. WR. | Taco
953-6284RP | RP,CASING,FI5013D,125# NO WR. | Taco
975-454RP | RP,KIT,CATRIDGE/ROTOR ASSY, VR25H VENDOR P/N 979525852TACO | Taco
975-486RP | RP KIT,CASING SEAL, VR15L,M, H - 30L,M,H ALL MODELS | Taco
VM1816-DY2-4S2W00 | CIRCULATOR | ECM | 0015e3 | 4 BOLT FLANGE | STAINLESS STEEL | DHW | Taco
Z050P2-2 | 1/2" 2-Way Zone Sentry Valve Normally Closed (Press) | Taco
Z100C2-2 | 1" Zone Sentry Valve Normally Closed (Sweat) | Taco
Z050T3-2 | 1/2" 3-Way Zone Sentry Valve Normally Closed (Threaded) | Taco
Z075C3-2 | 3/4" Zone Sentry Valve, 3 Way Normally Closed (Sweat) | Taco
V075C2A2ZB024Q4A2 | 3/4" Zone Sentry Valve, Normally Open (Sweat) | Taco
V100T3G1ZA024Q4A2 | 1" 3-Way Geo-Sentry GeoThermal Zone Valve - Threaded, Normally Closed | Taco
VM3450-HD1-RC2W00 | 0034e CAST IRON CIRCULATOR (ANALOG) | Taco
VB1016-DY2-US2W00 | CIRCULATOR | ECM | 007e | UNION | STAINLESS STEEL | DHW | Taco
VM2644-DD1-RS2W00 | 0026e STAINLESS STEEL CIRCULATOR (ANALOG) | Taco
V075P2A1ZB024Q4A2 | 3/4" 2-Way Zone Sentry Valve Normally Open (Press) | Taco
SR1A-001RP | Replacement Fuse - 1 Amp (10 Pack) | Taco
SFL-125T | 1-1/4" Threaded Shut-Off Freedom Swivel-Flange Set | Taco
VR1816-DY2-US2W00 | CIRCULATOR | ECM | 0018e | UNION | STAINLESS STEEL | DHW | Taco
V100T2G2ZB024Q4A2 | GEO-SENTRY 1" NPT 2-WAY N.O. 24V GEO-OPEN SYSTEM | Taco
V075T3A1ZALNVE2A1 | ZONE SENTRY 3/4" NPT 3-WAY DIV MULTI VOLT | Taco
VB1016-HY2-4C2A00 | CIRCULATOR | ECM | 4 BOLT FLANGE | CAST IRON | Taco
Posts
NEMA Enclosure Ratings Chart: How to Choose Nema-Rated Enclosure for Your Application
Vaisala’s Calibrating Measurement Instruments Guide: Benefits of Sensor Calibration by Manufacturers
Do AquaMotion Hot Water Recirculation Systems Solve North American Water Shortage Problems?
In Stock: New iO's CO2-TH and iO-HPA Proactive Warning Solutions
Introducing New DIN Rail Control Relays by Functional Devices
Senva Sensors: Build a Universal Air Quality Control System
Carbon Monoxide and Smoke Detectors: The Buyer’s Guide
PACKAGED TERMINAL AIR CONDITIONER VS MINI SPLIT UNIT: THE BUYER'S GUIDE
5 Tips for More Sustainable HVAC Systems
Circuit Breaker Basics: All You Need to Know About Household Circuit Breakers
WHAT ARE FIRE DAMPERS IN HVAC SYSTEMS AND HOW DO THEY WORK?
UV HVAC Systems: Does Ultraviolet Improve Air Quality?
Recirculating Hot Water Systems: The Buyers Guide
Using BACnet for Automation: All You Need to Know
Sensors vs Transducers: What Is the Key Difference?
PVC for Plumbing: 11 Advantages of PVC Pipes and Fittings
Going Remote: 7 Benefits of Wireless HVAC Controls
HVAC Valve & Damper Actuators: 4 Main Types
SEASONAL ROOFTOP UNIT MAINTENANCE CHECKLIST: FROM AIR FILTERS TO DRAINAGE SYSTEM CHECK
Commercial vs Residential HVAC Systems: 6 Main Differences
6 Benefits of Air Balancing for Your HVAC System
Tips for Controlling the Indoor Humidity
Radiator Valves: All You Need to Know
9 Signs Your HVAC System Needs Repairs
How Air Conditioner Works: 7 Main Parts of an AC Unit
Air Conditioner Freezing Up: Causes, Solutions & Ways to Prevent
Winter Commercial Building Maintenance: Tips & Checklist
ERV vs. HRV: What’s The Difference?
How to Prepare Your HVAC for Winter
Power Outage 101: Everything You Need to Know about Power Outages
13 Tips to Keep Your House Warm This Winter
5 Power Surge Causes: How to Protect Your Devices?
How to Do DIY Home Energy Audit
WHAT IS THE DIFFERENCE BETWEEN BACNET IP VS. BACNET MS/TP: WHY CHOOSE BACNET IP VS MSTP?
6 Tips for Getting The Most Out of Air Filters
Different Types of Control Valves: Key Features and Applications
Do Smart Thermostats Save Money?
Top Summer HVAC Maintenance Tips
Types of Pipe Fittings: Styles, Materials, Applications
How to Add Home Equity with HVAC Improvements
Everything You Need to Know About Gas Detectors
What Check Valve Should I Use?
7 Signs Your Home Needs a Dehumidifier: In-Depth Guide
7 Easy Solutions & Tips to Improve Your Plumbing
Spring Return vs. Double Acting Actuator: Which Actuator to Choose?
Guide on Central Heating Temperature Controls: Choosing a Thermostat