Collections
Air Diffusers, Grilles & Register
Schedule 40 PVC Plastic Fittings
Schedule 80 PVC Plastic Fittings
Schedule 80 CPVC Plastic Fittings
Plastic PVC Schedule 80 Fittings
Plastic PVC Schedule 80 Nipples
Drain Waste Vent DWV Plastic Fittings
Pressure & Flow Control Valves
Stainless Steel Mini Ball Valves
Chrome Plated Brass Mini Ball Valves
Bulkhead/Anchor/Frame Couplings
Double Compression Brass Fittings
Check and Anti Siphon Brass Valves
1/4 Industrial Interchange Pneumatic Fittings
Pressure Washer Pneumatic Fittings
Bulkhead Steel 37 Degree JIC Flare
Straights Steel 37 Degree JIC Flare
Shapes Steel 37 Degree JIC Flare
Stainless Steel Flareless Bite Fittings
Stainless Steel Push On Hose Barb
3000# 316 Stainless Steel Fittings
Brands
Products
SVT-4 | Solenoid valve enclosure with timer | 90-240 VAC | 4 valves. | Dwyer
TE-DFN-A0444-00 | Air Duct Temperature Sensor | 4 inch probe | 10K Ohm Type III Thermistor. | Dwyer
TE-NND-E | NA Wall Mount Temperature Sensor | PT1K Ohm RTD Sensor | Dwyer
TCS-K | K type thermocouple | 4" probe | 48" extension. | Dwyer
SBSV-S4F1 | 2-way 316SS solenoid valve | 1/2" | 7.28-188.5 psi | FKM seal | 110 VAC | Dwyer
SG5-G0522N | 4.5" Contractor gage | 0 to 100 psi | 1/4" NPT bottom connection | Dwyer
TCS-4040 | Thermocouple temperature switch | type J/K/S Input | 24 VAC/VDC | °C. | Dwyer
STC351 | Pipe-mount bimetal surface thermometer | range -50 to 250°F | 1" to 1-5/8" pipe. | Dwyer
SVT-6 | Solenoid valve enclosure with timer | 90-240 VAC | 6 valves. | Dwyer
STC141 | Pipe-mount bimetal surface thermometer | range 0 to 150°F | 3/4" to 7/8" pipe. | Dwyer
RMA-45 | Flowmeter | range 5-50 GPH water | no valve. | Dwyer
SFI-550-3/4 | Sight window | 3/4" male NPT. | Dwyer
SGZ-D10442N-GF | 2.5" SS Gage | 1/4" npt back connection | range 60 psi | glycerin filled | Dwyer
SGY-D10122N | 2.5" SS gage | 1/4" npt bottom connection | range 30" Hg | Dwyer
SG5-G0322N | 4.5" Contractor gage | 0 to 30 psi | 1/4" NPT bottom connection | Dwyer
RSME-B-014-SS | Room status monitor | range -0.5-0-0.5" w.c. | ± 0.5% accuracy with SS bezel | Dwyer
SBSV-B6N3 | 2-way brass solenoid valve | 1" | 7.25-188.5 psi | nbr seal | 24 VAC | Dwyer
SCL1290 | Thermocouple input limit/alarm switch module | low voltage supply. | Dwyer
RSME-C-003-SS | Room status monitor | range 0-0.5" w.c. | ± 1.0% accuracy with SS bezel | Dwyer
SBSV-B5N1 | 2-way brass solenoid valve | 3/4" | 7.25-188.5 psi | nbr seal | 110 VAC | Dwyer
SBLT2-5-40 | Series SBLT2 & SBLTX Submersible Level Transmitter 0-5 psi sensor, 40 ft. cable | Dwyer
RMC-144-SSV | Flowmeter | range .8-7 GPM water. | Dwyer
RMA-42-SSV | Flowmeter | range 1-11 GPH water. | Dwyer
RMA-42 | Flowmeter | range 1-11 GPH water | no valve. | Dwyer
RSME-B-005 | Room status monitor | range 0-2.0" w.c. | ± 0.5% accuracy | Dwyer
RTD-646 | Resistance temperature detector | 6" (15 cm) length | 1/4" dia. | Dwyer
RSME-B-016 | Room status monitor | range -2-0-2" w.c. | ± 0.5% accuracy | Dwyer
RSME-C-015-SS | Room status monitor | range -1-0-1" w.c. | ± 1.0% accuracy with SS bezel | Dwyer
RSME-B-014 | Room status monitor | range -0.5-0-0.5" w.c. | ± 0.5% accuracy | Dwyer
RSM-2-A | Room status monitor | range ±0.1" w.c. | excitation 24 VAC. | Dwyer
RMA-8 | Flowmeter | range 10-100 SCFH air | no valve. | Dwyer
RMC-122 | Flowmeter | range 2-20 SCFM air. | Dwyer
RMA-14-SSV | Flowmeter | range 200-2500 cc/min air. | Dwyer
RMB-83-SSV | Flowmeter | range 1-20 GPH water. | Dwyer
RSM-2-B | Room status monitor | range ±0.1" w.c. | excitation 120 VAC. | Dwyer
RMC-101 | Flowmeter | range 5-50 SCFH air. | Dwyer
RMC-143-SSV | Flowmeter | range .4-4 GPM water. | Dwyer
RMB-49 | Flowmeter | range .5-5 SCFH air. ±5% accuracy. | Dwyer
RMC-143 | Flowmeter | range .4-4 GPM water. | Dwyer
RMC-123-SSV | Flowmeter | range 3-30 SCFM air. | Dwyer
RMA-26 | Flowmeter | range .5-5 LPM air | no valve. | Dwyer
RMC-121 | Flowmeter | range 1-10 SCFM air. | Dwyer
RMB-85D-SSV | Flowmeter | range 10-100 GPH/0.8-6.2 LPM water. | Dwyer
RMC-142 | Flowmeter | range .2-2.2 GPM water. | Dwyer
RMC-123 | Flowmeter | range 3-30 SCFM air. | Dwyer
RMC-106-SSV | Flowmeter | range 100-1000 SCFH air. | Dwyer
RMB-85-SSV | Flowmeter | range 10-100 GPH water. | Dwyer
RMA-44-SSV | Flowmeter | range 4-34 GPH water. | Dwyer
RMA-5 | Flowmeter | range 1-10 SCFH air | no valve. | Dwyer
RMA-23-TMV | Flowmeter | range 5-50 LPM air. | Dwyer
RMB-54 | Flowmeter | range 20-200 SCFH air. | Dwyer
RMC-102 | Flowmeter | range 10-100 SCFH air. | Dwyer
RMA-4-SSV | Flowmeter | range .5-5 SCFH air. | Dwyer
PS124 | Pressure snubber | for air & gas service | 1/4" NPT. | Dwyer
RMA-12-TMV | Flowmeter | range 50-500 cc/min air. | Dwyer
RMA-11-SSV | Flowmeter | range 30-200 cc/min air. | Dwyer
RDCS35T | 1-1/2" diaphragm valve | remote coil | NPT connection. | Dwyer
OLS-10 | Optical level switch | 316 SS/Polysulfone wetted materials. | Dwyer
P2-15 | Flow switch for gases | actuation set point .42 CFM (11.9 LPM) @ 5 psi. | Dwyer
MPR2-1 | Miniature pressure regulator | range 0-15 psi. | Dwyer
MVB-WM1 | Mini Brass Ball Valve | wedge handle | 450 psi | 1/8" | Dwyer
MMF-2 | Flowmeter | range .2-2 SCFH air. | Dwyer
MMA-30 | Flowmeter | range 1-8 GPH water. | Dwyer
MMA-40-LV | Flowmeter | range .1-1.1 LPM water | less configurable valve. | Dwyer
MP-005 | Differential pressure switch/gage | range 0-5.0" water. | Dwyer
MMA-38 | Flowmeter | range 50-500 cc/min water. | Dwyer
MMA-23-LV | Flowmeter | range 1-10 LPM air | less configurable valve. | Dwyer
MMF-10-TMV | Flowmeter | range 1-10 SCFH air. | Dwyer
MMA-25-LV | Flowmeter | range 5-50 LPM air | less configurable valve. | Dwyer
MARK II WSI | Wind speed indicator | MPH scale. | Dwyer
ITA9604D | Industrial thermometer | range 30 to 180°F (0 to 80°C). | Dwyer
LPG4-D9322N | Low pressure gage | range -24-0-40" w.c. (-6-0-10 kPa). | Dwyer
LPG5-D8822N | 2.5" low pressure gage | dual range 0-200" w.c.(0-50 kPa) | bottom connection | Dwyer
M480 | Vaneometer | 0-2.0 m/s. | Dwyer
IWP-03 | Industrial weatherproof pressure transmitter | 200 psig | Dwyer
ITA9606D | Industrial thermometer | range 30 to 300°F (0 to 150°C). | Dwyer
HNV-SSS22B | 1/4" needle valve | female x male. | Dwyer
L4-SS | Float switch | 316SS body | 316SS float | side wall mounting. | Dwyer
LCT316-400 | Low cost digital timer | 24 VAC/DC supply voltage. | Dwyer
L4TOP | Float switch | brass | SPDT | (V=4 | H=3) | Dwyer
IWP-02 | Industrial weatherproof pressure transmitter | 100 psig | Dwyer
IP-42 | Current to pressure transducer | 4-20 mA input | 3-15 psi (20-100 kPa) output. | Dwyer
I2-17042 | Immersion temperature sensor | 4" insertion length | 5K Ω NTC Thermistor. | Dwyer
I2-15042 | Immersion temperature sensor | 4" insertion length | 10K Ω NTC Type 2 Thermistor. | Dwyer
BTT-D04-1 | Duct Mount Temperature Transmitter with 4 to 20 mA output | 4" probe | Dwyer
HS-311 | Humidity switch | 0-3 V input sensor | 110 VAC supply voltage. | Dwyer
HHT-EU-LCD | Explosion-proof humidity transmitter with LCD display. | Dwyer
HHT-EU | Explosion-proof humidity transmitter. | Dwyer
HHT-IT | Intrinsically safe humidity/temperature transmitter. | Dwyer
F195 | Disposable in-line filter. | Dwyer
DS-300-4-LV | Flow sensor | 4" pipe size | without valves. | Dwyer
F760N | Nylon liquid/particle filter with 1/4" NPT connection and 10.5 in³ internal volume. | Dwyer
DTFO-2B-4O | Range 0-4 gpm oil | 1/2" npt | brass body | Dwyer
EBV-2 | Electric bin vibrator | 243 lb centrifugal force. | Dwyer
DS-300-2-1/2 | Flow sensor | 2-1/2" pipe size. | Dwyer
DSGT-110-C0S | Digital indicating transmitter | range 0-600 psig. | Dwyer
DTFO-1B-4O | Range 0-4 gpm oil | 1/4" npt | brass body | Dwyer
DPMW-404 | LCD digital panel meter | loop powered 4 to 20 mA | red segments. | Dwyer
DS-300-6 | Flow sensor | 6" pipe size. | Dwyer
DS-300-2 | Flow sensor | 2" pipe size. | Dwyer
DPMP-503 | LCD digital panel meter | voltage powered 12VDC/24VDC | red segments. | Dwyer
DCT1010DC | Dust collector timer controller | 10 channels. | Dwyer
DPMP-403 | LCD digital process meter | loop powered 4 to 20 mA | red segments. | Dwyer
DPT-A05 | Digital pressure transmitter | range 0 to 100 psig | 4-20 mA output. | Dwyer
DHC-010 | Differential pressure controller | range 25 in w.c. | Dwyer
DM-007 | Differential digital pressure transmitter | range 0-3.0" w.c. | Dwyer
DPG-200 | Digital pressure gage | selectable engineering units: -14.70-0 psig | Dwyer
DHII-009 | Differential pressure controller | selectable engineering units: 50.00" w.c. | Dwyer
DFMT2-50A | Remote Digital Flow Transmitter | 2" NPT | Dwyer
DHC-209 | Differential pressure controller | range ±10 in w.c. | Dwyer
DHC-204 | Differential pressure controller | range ±1.0 in w.c. | Dwyer
DCT622 | Timer controller | 22 channels. | Dwyer
DCT606 | Timer controller | 6 channels. | Dwyer
A-368 | Surface mounting plate | aluminum | for Magnehelic® gage. | Dwyer
DBTA3901 | Digital solar-powered bimetal thermometer | range -58 to 302°F | 9" stem. | Dwyer
DBTA3402 | Digital solar-powered bimetal thermometer | range -58 to 158°F | 4" stem. | Dwyer
Posts
NEMA Enclosure Ratings Chart: How to Choose Nema-Rated Enclosure for Your Application
Vaisala’s Calibrating Measurement Instruments Guide: Benefits of Sensor Calibration by Manufacturers
Do AquaMotion Hot Water Recirculation Systems Solve North American Water Shortage Problems?
In Stock: New iO's CO2-TH and iO-HPA Proactive Warning Solutions
Introducing New DIN Rail Control Relays by Functional Devices
Senva Sensors: Build a Universal Air Quality Control System
Carbon Monoxide and Smoke Detectors: The Buyer’s Guide
PACKAGED TERMINAL AIR CONDITIONER VS MINI SPLIT UNIT: THE BUYER'S GUIDE
5 Tips for More Sustainable HVAC Systems
Circuit Breaker Basics: All You Need to Know About Household Circuit Breakers
WHAT ARE FIRE DAMPERS IN HVAC SYSTEMS AND HOW DO THEY WORK?
UV HVAC Systems: Does Ultraviolet Improve Air Quality?
Recirculating Hot Water Systems: The Buyers Guide
Using BACnet for Automation: All You Need to Know
Sensors vs Transducers: What Is the Key Difference?
PVC for Plumbing: 11 Advantages of PVC Pipes and Fittings
Going Remote: 7 Benefits of Wireless HVAC Controls
HVAC Valve & Damper Actuators: 4 Main Types
SEASONAL ROOFTOP UNIT MAINTENANCE CHECKLIST: FROM AIR FILTERS TO DRAINAGE SYSTEM CHECK
Commercial vs Residential HVAC Systems: 6 Main Differences
6 Benefits of Air Balancing for Your HVAC System
Tips for Controlling the Indoor Humidity
Radiator Valves: All You Need to Know
9 Signs Your HVAC System Needs Repairs
How Air Conditioner Works: 7 Main Parts of an AC Unit
Air Conditioner Freezing Up: Causes, Solutions & Ways to Prevent
Winter Commercial Building Maintenance: Tips & Checklist
ERV vs. HRV: What’s The Difference?
How to Prepare Your HVAC for Winter
Power Outage 101: Everything You Need to Know about Power Outages
13 Tips to Keep Your House Warm This Winter
5 Power Surge Causes: How to Protect Your Devices?
How to Do DIY Home Energy Audit
WHAT IS THE DIFFERENCE BETWEEN BACNET IP VS. BACNET MS/TP: WHY CHOOSE BACNET IP VS MSTP?
6 Tips for Getting The Most Out of Air Filters
Different Types of Control Valves: Key Features and Applications
Do Smart Thermostats Save Money?
Top Summer HVAC Maintenance Tips
Types of Pipe Fittings: Styles, Materials, Applications
How to Add Home Equity with HVAC Improvements
Everything You Need to Know About Gas Detectors
What Check Valve Should I Use?
7 Signs Your Home Needs a Dehumidifier: In-Depth Guide
7 Easy Solutions & Tips to Improve Your Plumbing
Spring Return vs. Double Acting Actuator: Which Actuator to Choose?
Guide on Central Heating Temperature Controls: Choosing a Thermostat