current sensors
![Veris H921 Current Transducer | Split-Core | 0-120A | 4-20mA | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H921_medium.jpg?v=1706643274)
![Veris H608 Mini Split-Core | Adj. | Range: 0.50-175AAC Output: N.O. | 1.0A | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/H608_f204436b-5583-44d3-9965-7fbdaa5b60aa_medium.jpg?v=1718306602)
![Veris H300 Current Switch | Mico | Split-Core | Fixed | N.O | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H300_medium.jpg?v=1689243581)
![Veris H735 Current Switch/Relay Combo | Solid Core | SPST | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H735_medium.jpg?v=1706643284)
![Veris H221 Split Core | Span Adj. | Range: 0-300AAC | Output: 4-20mA | Loop | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/H221_medium.jpg?v=1717426078)
![Veris H938 Current Switch/Relay Combo | Split Core | Adj. | SPST | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/H938_41805154-3599-4180-87ce-111704660c0b_medium.jpg?v=1711573708)
![Veris H321 Split Core | Span Adj. | Range: 0-800AAC | Output: 4-20mA | Loop | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/H321_4034591a-8fbb-4ded-bfc7-cb1b21729adf_medium.jpg?v=1717610111)
![Veris H721LC Solid Core | Range:0-10 | 0-20 | 0-40AAC Sw Select | Output:4-20mA | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H721_medium.jpg?v=1689243578)
![Veris H922 Current Transducer | Split-Core | 0-120A | 0-5VDC | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H922_10874971-6f23-4531-aaf8-56e57ce30636_medium.jpg?v=1706643280)
![Senva Sensors C-2300 Fixed, 0.35-200A, split core | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/C-2300_medium.png?v=1708975194)
![Veris H120 Enclosed Relay | Current Switch 20A | Fixed | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H120_5e9e1a95-2264-4137-b25a-dab3748e7c47_medium.jpg?v=1689243589)
![Functional Devices RIBXKTF Enclosed Solid-Core AC Sensor, .25-150Amp, fixed, terminals | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/RIBXKTF_medium.jpg?v=1708365201)
![Functional Devices RIBXGTF Enclosed Split-Core AC Sensor, .35-150Amp, fixed, terminals | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/RIBXGTF_cb7b5680-242b-4f47-af77-72efbeb99a77_medium.jpg?v=1708365219)
![Veris H800 Solid Core | Fixed | Range: 0.25-200AAC | Output: N.O. | 1.0A@30V | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H800_medium.jpg?v=1689243579)
![Senva Sensors C-2320-L Preset, 0.45-50A, split core | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/preset-category-transparent_75f7d26c-40a3-4bf0-bcf5-0c4a5217c854_medium.jpg?v=1712258131)
![Senva Sensors C-2345 Analog 4-20mA, 30/60/120A, split core | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/C-2345_medium.png?v=1712175855)
![Veris H308 Current Switch | Micro | Split-Core | Adj | N.O | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H308_medium.jpg?v=1706643270)
![Veris H900 Split Core | Fixed | Range: 1.5-200AAC | Output: N.O. | 1.0A@30V | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/H900_medium.jpg?v=1706643280)
![Mamac CT-800 Current Switch (Solid Core) | Trip Point: 0.5A | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/CT-800_medium.png?v=1713900903)
![Veris H721HC Solid Core | Range:0-50 | 0-100 | 0-200AAC Sw Select | Output:4-20mA | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/H721HC_medium.jpg?v=1712781618)
![Veris H701 Solid Core | Adj. | Range: 1-135AAC | Output: N.O. | 1.0A@30VAC/ | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/H701_720993e0-436f-4f07-8cfc-3cbae517174b_medium.jpg?v=1712258627)
Everything You Need to Know About Current Sensors
Current sensors are electronic devices that measure and detect the flow of electric current in a circuit. They are essential in many applications where accurate measurement and control of a current are required, be that a data acquisition system, HVAC, or a building automation system.
What Are Current Sensors?
Current sensors are devices that measure the electric current flowing through a conductor. They are important because they enable the monitoring and control of currents in various applications, including power monitoring, electric vehicle charging, renewable energy systems, industrial automation, and smart grids.
Applications of Current Sensors
Current sensors find widespread use in various industries and applications, including:
- Power monitoring and control systems: Current sensors are used to measure the amount of power consumed by different electrical devices and systems.
- Electric vehicle charging: Current sensors are used to measure the charging current and monitor the battery's state of charge in electric vehicles.
- Renewable energy systems: Current sensors are used to measure the current generated by renewable energy systems such as solar panels and wind turbines.
- Industrial automation: Current sensors are used in industrial automation to monitor and control the current flowing through different machines and systems.
- Smart grids: Current sensors are used in smart grid systems to monitor and control the flow of electricity in the grid.
Different Types of Current Sensors
![Current Sensors](https://cdn.shopify.com/s/files/1/0877/4530/files/CurrentSensors_600x600.jpg?v=1684305901)
There are several types of current sensors available in the market. Some of the commonly used types are:
Hall Effect Sensors
A Hall Effect sensor uses the principle of the Hall Effect to measure the magnetic field generated by the current flowing through a conductor. They are contactless and do not require a physical connection to the conductor.
Advantages:
- Contactless measurement
- High accuracy
- Wide dynamic range
Disadvantages:
- Limited frequency response
- Sensitive to external magnetic fields
Applications:
- Motor control
- Power supplies
- Industrial automation
Split-Core Sensors
![SPLIT-CORE](https://cdn.shopify.com/s/files/1/0877/4530/files/SPLIT-CORE_480x480.jpg?v=1684306106)
Split-core current sensors are designed to be installed around an existing conductor, eliminating the need to disconnect the circuit. They are widely used in retrofit applications, where it is difficult to access the conductor.
Advantages:
- Easy to install
- Suitable for retrofit applications
- Non-invasive measurement
Disadvantages:
- Limited accuracy
- Limited frequency response
- Sensitive to external magnetic field
Applications:
- Building automation
- Energy monitoring
- Power quality analysis
Solid Core Sensors
![SOLID CORE](https://cdn.shopify.com/s/files/1/0877/4530/files/SOLIDCORE_480x480.jpg?v=1684306170)
Solid core current sensors are designed to be installed around a conductor during installation. They provide accurate and reliable conductor current sensing.
Advantages:
- High accuracy
- Wide dynamic range
- Isolated measurement
Disadvantages:
- Requires physical connection to the conductor
- Limited flexibility
Applications:
- Power monitoring
- Protection relays
- Energy metering
Closed-Loop Current Sensors
Closed-loop sensors use a feedback loop to provide accurate and stable measurements of the current flowing through the conductor. They are widely used in applications where high accuracy and stability are required.
Advantages:
- High accuracy
- Stable measurement
- Wide dynamic range
Disadvantages:
- Expensive
- Requires additional circuitry
Applications:
- Industrial automation
- Motor control
- Power supplies
Open Loop Current Sensors
Open-loop sensors provide a voltage output proportional to the current flowing through the conductor. An open-loop sensor does not require a feedback loop and is typically less expensive than a closed-loop current sensor.
Advantages:
- Low cost
- Easy to use
- Suitable for low-frequency applications
Disadvantages:
- Limited accuracy
- Limited dynamic range
- Sensitive to external magnetic fields
Applications:
- Lighting control
- HVAC control
- Battery management systems
Сurrent Transformers
A current transformer is a passive device that uses a magnetic core to induce a current in the secondary winding proportional to the current flowing through the primary winding.
Advantages:
- High accuracy
- Wide dynamic range
- Isolated measurement
Disadvantages:
- Limited frequency response
- Requires physical connection to the conductor
Applications:
- Power monitoring
- Protection relays
- Energy metering
Rogowski Coils
Rogowski Coils are flexible current sensors that measure the rate of change of the current in a conductor. They are contactless and do not require a physical connection to the conductor.
Advantages:
- Contactless measurement
- High-frequency response
- Large dynamic range
Disadvantages:
- Low accuracy
- Sensitive to external magnetic fields
Applications:
- High-speed motor control
- Power Electronics
- Current transient analysis
Operating Principles of Current Sensors
Current sensors operate based on various principles such as magnetic field, the Hall Effect, and electromagnetic induction. The following are some of the commonly used operating principles of current sensors:
Magnetic Field Principle
Magnetic sensors use the magnetic field produced by the current flowing through a conductor to measure the current.
Hall Effect Principle
A Hall Effect current sensor uses the Hall Effect to measure the magnetic field generated by the current flowing through a conductor.
Current Transformers
Current transformers use the principle of electromagnetic induction to measure the current flowing through a conductor.
Rogowski Coils
Rogowski Coils measure the rate of change of current in a conductor using electromagnetic induction.
Choosing the Right Current Sensor
Choosing the right current sensor depends on specific application requirements such as measurement range, accuracy, frequency response, and physical constraints. It is essential to consider the cost, performance, and availability of the sensor before making a decision.
Conclusion
At Blackhawk Supply, we offer a wide range of high-quality current sensors from leading manufacturers such as Veris Industries, NK Technologies, and Senva. Contact us today to learn more about our products and how we can help you choose the right current sensor for your application.
Visit our website to browse our selection of current sensors and contact us for expert advice and support.
Popular Products
View all →![Veris H971 Current Sensor | DC | Split | 0-200A | Pulse Reset | Bi-Directional | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/H971_2713e501-214a-425b-84fa-558ce4a2feb2_large.jpg?v=1717708350)
![Siemens SAS61.33U MT Series SAS Electronic Valve Act, SR, 24V, 0-10V / 4-20 mA Proport Control | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/SAS61.33U_large.jpg?v=1716574569)
![Siemens RDY2000BN BACnet Commercial Thermostat | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/RDY2000BN_large.jpg?v=1716932364)
![Veris PW2LX05S Pressure | Wet | NEMA 4 | LCD | 0-250PSID | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/PW2LX05S_638c61e7-cf7e-4442-bf77-b59f0bbc5fde_large.jpg?v=1692624166)
![Viconics R820-643-REV2 SCR Power controller 600 V, 45 A, 3 phase | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/r820_ab49eea2-b198-48f5-9000-5151691a676d_large.jpg?v=1715696897)
![iO HVAC Controls iO-WR-XR Extended Range wireless relay kit | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/products/iO_WR_XR_web_b1a67703-1116-4d67-b510-b2685656413f_large.png?v=1709052496)