Sitemap

Pages

Brands

Products

TE-D-3 | PTFE orifice plate flowmeter | 1-1/4" line size | 1.00" bore | 0.72 Beta | water capacity: 320" d.p. W/C | 71.77 GPM flow; air capacity: 180 SCFM @ 14.7 psia | 309.97 SCFM @ 20 psig | 595.2 SCFM @ 100 psig; 1 lb. | DwyerTE-E-2 | PTFE orifice plate flowmeter | 1-1/2" line size | 0.800" bore | 0.5 Beta | water capacity: 100" d.p. W/C | 22.73 GPM flow; air capacity: 80.82 SCFM @ 14.7 psia | 129.68 SCFM @ 20 psig | 241.5 SCFM @ 100 psig; 2 lb. | DwyerTE-D-2 | PTFE orifice plate flowmeter | 1-1/4" line size | 0.700" bore | 0.51 Beta | water capacity: 100" d.p. W/C | 17.48 GPM flow; air capacity: 62.09 SCFM @ 14.7 psia | 99.75 SCFM @ 20 psig | 185.5 SCFM @ 100 psig; 1 lb. | DwyerTE-D-1 | PTFE orifice plate flowmeter | 1-1/4" line size | 0.400" bore | 0.29 Beta | water capacity: 20" d.p. W/C | 2.46 GPM flow; air capacity: 9.31 SCFM @ 14.7 psia | 14.41 SCFM @ 20 psig | 26.3 SCFM @ 100 psig; 1 lb. | DwyerTE-C-1 | PTFE orifice plate flowmeter | 1" line size | 0.300" bore | 0.29 Beta | water capacity: 20" d.p. W/C | 1.38 GPM flow; air capacity: 5.24 SCFM @ 14.7 psia | 8.11 SCFM @ 20 psig | 14.8 SCFM @ 100 psig; 1 lb. | DwyerTE-C-3 | PTFE orifice plate flowmeter | 1" line size | 0.720" bore | 0.69 Beta | water capacity: 320" d.p. W/C | 36.15 GPM flow; air capacity: 91.28 SCFM @ 14.7 psia | 156.51 SCFM @ 20 psig | 300 SCFM @ 100 psig; 1 lb. | DwyerTE-C-2 | PTFE orifice plate flowmeter | 1" line size | 0.520" bore | 0.49 Beta | water capacity: 100" d.p. W/C | 9.63 GPM flow; air capacity: 34.2 SCFM @ 14.7 psia | 54.92 SCFM @ 20 psig | 102.09 SCFM @ 100 psig; 1 lb. | DwyerHFS-2-02 | In-line flow monitor | 1/2" female NPT | 0.2-2 GPM (.75-7.5 LPM) water. | DwyerHFS-2-10 | In-line flow monitor | 1/2" female NPT | 0.5-10 GPM (1.9-38 LPM) water. | DwyerHFL-4-25 | In-line flow monitor | 1" female NPT | 2-25 GPM (7.5-95 LPM) oil. | DwyerHFL-2-05 | In-line flow monitor | 1/2" female NPT | 0.5-5 GPM (1-19 LPM) oil. | DwyerHFH-4-35 | In-line flow monitor | 1" female NPT | 5-35 GPM (19-130 LPM) water. | DwyerHFH-2-10 | In-line flow monitor | 1/2" female NPT | 1-10 GPM (3.8-38 LPM) water. | DwyerHFH-2-05 | In-line flow monitor | 1/2" female NPT | 0.5-5 GPM (1-19 LPM) water. | DwyerHFB-6-75 | In-line flow monitor | 2" female NPT | 8-75 GPM (31-284 LPM) water. | DwyerHFB-6-150 | In-line flow monitor | 2" female NPT | 20-150 GPM (76-568 LPM) water. | DwyerHFB-5-50 | In-line flow monitor | 1-1/2" female NPT | 5-50 GPM (19-189 LPM) water. | DwyerHFB-5-100 | In-line flow monitor | 1-1/2" female NPT | 10-100 GPM (38-379 LPM) water. | DwyerHFB-4-35 | In-line flow monitor | 1" female NPT | 5-35 GPM (19-130 LPM) water. | DwyerHFB-3-20 | In-line flow monitor | 3/4" female NPT | 2-20 GPM (7.5-75 LPM) water. | DwyerHFB-3-15 | In-line flow monitor | 3/4" female NPT | 2-15 GPM (7.5-55 LPM) water. | DwyerHFB-2-05 | In-line flow monitor | 1/2" female NPT | 0.5-5 GPM (1-19 LPM) water. | DwyerDTFW-3S-30W | Range 0-30 GPM water | 1" npt | ss body | DwyerDTFW-3S-25W | Range 0-25 GPM water | 1" npt | ss body | DwyerDTFW-3S-20W | Range 0-20 GPM water | 1" npt | ss body | DwyerDTFW-3S-15W | Range 0-15 GPM water | 1" npt | ss body | DwyerDTFW-3S-10W | Range 0-10 GPM water | 1" npt | ss body | DwyerDTFW-2S-8W | Range 0-8 GPM water | 1/2" npt | ss body | DwyerDTFW-2S-5W | Range 0-5 GPM water | 1/2" npt | ss body | DwyerDTFW-2S-3W | Range 0-3 GPM water | 1/2" npt | ss body | DwyerDTFW-2S-2W | Range 0-2 GPM water | 1/2" npt | ss body | DwyerDTFW-2S-1W | Range 0-1 GPM water | 1/2" npt | ss body | DwyerDTFW-2S-10W | Range 0-10 GPM water | 1/2" npt | ss body | DwyerDTFW-2B-8W | Range 0-8 GPM water | 1/2" npt | brass body | DwyerDTFW-2B-5W | Range 0-5 GPM water | 1/2" npt | brass body | DwyerDTFW-2B-3W | Range 0-3 GPM water | 1/2" npt | brass body | DwyerDTFW-2B-2W | Range 0-2 GPM water | 1/2" npt | brass body | DwyerDTFW-2B-1W | Range 0-1 GPM water | 1/2" npt | brass body | DwyerDTFW-2B-10W | Range 0-10 GPM water | 1/2" npt | brass body | DwyerDTFW-1S-5W | Range 0-5 GPM water | 1/4" npt | ss body | DwyerDTFW-1S-2W | Range 0-2 GPM water | 1/4" npt | ss body | DwyerDTFW-1S-1W | Range 0-1 GPM water | 1/4" npt | ss body | DwyerDTFW-1B-5W | Range 0-5 GPM water | 1/4" npt | brass body | DwyerDTFW-1B-4W | Range 0-4 GPM water | 1/4" npt | brass body | DwyerDTFW-1B-3W | Range 0-3 GPM water | 1/4" npt | brass body | DwyerDTFW-1B-2W | Range 0-2 GPM water | 1/4" npt | brass body | DwyerDTFW-1B-1W | Range 0-1 GPM water | 1/4" npt | brass body | DwyerDTFF-1S-8W | Range 0-8 GPH | water calibration | 1/4" npt | DwyerDTFF-1S-8O | Range 0-8 GPH | oil calibration | 1/4" npt | DwyerDTFF-1S-5A | Range 1.5-5 SCFM | air calibration | 1/4" npt | DwyerDTFF-1S-4W | Range 0-4 GPH | water calibration | 1/4" npt | DwyerDTFF-1S-40W | Range 0-40 GPH | water calibration | 1/4" npt | DwyerDTFF-1S-15W | Range 0-15 GPH | water calibration | 1/4" npt | DwyerDTFF-1S-25W | Range 0-25 GPH | water calibration | 1/4" npt | DwyerDTFF-1S-10W | Range 0-10 GPH | water calibration | 1/4" npt | DwyerDTFO-3S-30O | Range 0-30 gpm oil | 1" npt | ss body | DwyerDTFO-3S-25O | Range 0-25 gpm oil | 1" npt | ss body | DwyerDTFO-3S-20O | Range 0-20 gpm oil | 1" npt | ss body | DwyerDTFO-3S-15O | Range 0-15 gpm oil | 1" npt | ss body | DwyerDTFO-2B-8O | Range 0-8 gpm oil | 1/2" npt | brass body | DwyerDTFO-2B-4O | Range 0-4 gpm oil | 1/2" npt | brass body | DwyerDTFO-1B-4O | Range 0-4 gpm oil | 1/4" npt | brass body | DwyerDTFA-2A-75A | Range 5.0-75 SCFM | 1/2" npt connection | DwyerDTFA-2A-50A | Range 4.0-50 SCFM | 1/2" npt connection | DwyerDTFA-2A-40A | Range 4.0-40 SCFM | 1/2" npt connection | DwyerDTFA-2A-30A | Range 3.0-30 SCFM | 1/2" npt connection | DwyerDTFA-2A-100A | Range 10.0-100 SCFM | 1/2" npt connection | DwyerDTFA-1A-25A | Range 3.0-25 SCFM | 1/4" npt connection | DwyerDTFA-1A-20A | Range 3.0-20 SCFM | 1/4" npt connection | DwyerDTFA-1A-15A | Range 2.0-15 SCFM | 1/4" npt connection | DwyerRMV-3-3 | Dial type flowmeter | 0-20 GPM water | 1" female NPT. | DwyerDTFA-1A-10A | Range 1.5-10 SCFM | 1/4" npt connection | DwyerRMV-2-3 | Dial type flowmeter | 0-10 GPM water | 1" female NPT. | DwyerRMV-1-3 | Dial type flowmeter | 0-5 GPM water | 1" female NPT. | DwyerRMVII-3 | Dial-type flowmeter | range 0-5 GPM water. | DwyerRMVII-22 | Dial-type flowmeter | range 0-8.5 GPM | 0-32 LPM oil. | DwyerRMVII-21 | Dial-type flowmeter | range 0-4.0 GPM | 0-15 LPM oil. | DwyerRMVII-20 | Dial-type flowmeter | range 0-2.2 GPM | 0-8 LPM oil. | DwyerRMVII-1 | Dial-type flowmeter | range 0-3 GPM water. | DwyerBFS-1 | Sensor for Series BFM. | DwyerBFM-3 | Control unit: NEMA 4X | polycarbonate housing | 12VDC. | DwyerBFM-2 | Control unit: NEMA 4X | polycarbonate housing | 220VAC. | DwyerBFM-1 | Control unit: NEMA 4X | polycarbonate housing | 120VAC. | DwyerTDFS2-2-P-06-BSPT | Thermal dispersion flow switch for pipe size 2 to 10" (50 to 250 mm) | 316SS | 1/2" BSPT process connection | 6' of cable with conduit connection. (Extended length) | DwyerTDFS2-2-C-06 | Thermal dispersion flow switch for pipe size 2 to 10" (50 to 250 mm) | 316SS | 1/2" NPT process connection | 6' of cable with conduit connection. (Extended length) | DwyerTDS212 | Thermal dispersion flow switch | PVDF wetted parts | 3.0" (7.6 cm) length. | DwyerTDS222 | Thermal dispersion flow switch | PVDF wetted parts | 4.5" (11.4 cm) length. | DwyerTDS122 | Thermal dispersion flow switch | PP/PPS wetted parts | 4.5" (11.4 cm) length. | DwyerTDS112 | Thermal dispersion flow switch | PP/PPS wetted parts | 3.0" (7.6 cm) length. | DwyerAFS-252 | Adjustable flow switch for gases | 1/2" NPT conduit connection | 316SS piston | 316SS housing. | DwyerAFS-251 | Adjustable flow switch for gases | 18 AWG | 24" polymeric lead wires | 316SS piston | 316SS housing. | DwyerAFS-232 | Adjustable flow switch for gases | 1/2" NPT conduit connection | brass piston | brass housing. | DwyerAFS-231 | Adjustable flow switch for gases | 18 AWG | 24" polymeric lead wires | brass piston | brass housing. | DwyerAFS-152 | Adjustable flow switch for liquids | 1/2" NPT conduit connection | 316SS piston | 316SS housing. | DwyerAFS-151 | Adjustable flow switch for liquids | 18 AWG | 24" polymeric lead wires | 316SS piston | 316SS housing. | DwyerAFS-142 | Adjustable flow switch for water | 1/2" NPT conduit connection | polysulfone piston | brass housing. | Dwyer (OBSOLETE)AFS-141 | Adjustable flow switch for water | 18 AWG | 24" polymeric lead wires | polysulfone piston | brass housing. | DwyerAFS-131 | Adjustable flow switch for oil | 18 AWG | 24" polymeric lead wires | brass piston | brass housing. | DwyerGVS-113 | Globe valve switch | actuation set point 2.0-8.0 GPM (7.6-30.3 LPM). | DwyerGVS-112 | Globe valve switch | actuation set point 5.0-15.0 GPM (18.9-56.8 LPM). | DwyerGVS-111 | Globe valve switch | actuation set point 1.0-6.0 GPM (3.8-22.7 LPM). | DwyerG9-23 | Globe flow switch | actuation set point 7.0-14.0 GPM (26.5-53.0 LPM). | DwyerG9-22 | Globe flow switch | actuation set point 2.0-8.0 GPM (7.6-30.3 LPM). | DwyerP8-15 | High pressure brass flow switch | actuation set point 2.0 GPM (7.57 LPM). | DwyerP8-14 | High pressure brass flow switch | actuation set point 1.5 GPM (5.68 LPM). | DwyerP8-13 | High pressure brass flow switch | actuation set point 1.0 GPM (3.79 LPM). | DwyerP8-12 | High pressure brass flow switch | actuation set point 0.50 GPM (1.89 LPM). | DwyerP8-11 | High pressure brass flow switch | actuation set point 0.25 GPM (.95 LPM). | DwyerP3-45 | Polypropylene flow switch | actuation set point 2.0 GPM (7.57 LPM) | Q disconnect. | DwyerP3-44 | Polypropylene flow switch | actuation set point 1.5 GPM (5.68 LPM) | Q disconnect. | DwyerP3-43 | Polypropylene flow switch | actuation set point 1.0 GPM (3.79 LPM) | Q disconnect. | DwyerP3-42 | Polypropylene flow switch | actuation set point 0.50 GPM (1.89 LPM) | Q disconnect. | DwyerP3-41 | Polypropylene flow switch | actuation set point 0.25 GPM (.95 LPM) | Q disconnect. | DwyerP3-35 | Polypropylene flow switch | actuation set point 2.0 GPM (7.57 LPM) | 3/8" NPT. | DwyerP3-34 | Polypropylene flow switch | actuation set point 1.5 GPM (5.68 LPM) | 3/8" NPT. | DwyerP3-33 | Polypropylene flow switch | actuation set point 1.0 GPM (3.79 LPM) | 3/8" NPT. | DwyerP3-32 | Polypropylene flow switch | actuation set point 0.50 GPM (1.89 LPM) | 3/8" NPT. | DwyerP3-31 | Polypropylene flow switch | actuation set point 0.25 GPM (.95 LPM) | 3/8" NPT. | DwyerP2-17 | Flow switch for gases | actuation set point 2.5 CFM (70.8 LPM) @ 5 psi. | DwyerP2-16 | Flow switch for gases | actuation set point 1 CFM (28.3 LPM) @ 5 psi. | DwyerP2-15 | Flow switch for gases | actuation set point .42 CFM (11.9 LPM) @ 5 psi. | DwyerP2-14 | Flow switch for liquids | actuation set point 1 GPM (3.79 LPM). | DwyerP2-13 | Flow switch for liquids | actuation set point .5 GPM (1.89 LPM). | DwyerP2-12 | Flow switch for liquids | actuation set point .25 GPM (.95 LPM). | DwyerP1-013 | Brass flow switch | actuation set point 0.50 GPM (1.89 LPM) | calibrated for water @ standard conditions. | DwyerFS-2-W8 | Paddle flow switch | 1" male NPT connection with 8 ft leads | DwyerFS-2-BSPT | Paddle flow switch | 1" male BSPT. | DwyerV10SS | Mini-size flow switch | 303 SS | normally open or closed. | DwyerV8 | Vane operated flow switch. | DwyerV8-WP | Vane operated flow switch with weatherproof enclosure (phenylpolioxide). | DwyerDS-400-8-LV | Flow sensor | 8" pipe size | without valves. | DwyerDS-400-8 | Flow sensor | 8" pipe size. | DwyerDS-400-6-LV | Flow sensor | 6" pipe size | without valves. | DwyerDS-400-6 | Flow sensor | 6" pipe size. | DwyerDS-400-24-LV | Flow sensor | 24" pipe size | without valves. | DwyerDS-400-24 | Flow sensor | 24" pipe size. | DwyerDS-400-20-LV | Flow sensor | 20" pipe size | without valves. | DwyerDS-400-20 | Flow sensor | 20" pipe size. | DwyerDS-400-18-LV | Flow sensor | 18" pipe size | without valves. | DwyerDS-300-1-LV | Flow sensor | 1" pipe size | without valves. | DwyerDS-400-18 | Flow sensor | 18" pipe size. | DwyerDS-300-2-LV | Flow sensor | 2" pipe size | without valves. | DwyerDS-400-16-LV | Flow sensor | 16" pipe size | without valves. | DwyerDS-300-2-1/2-LV | Flow sensor | 2-1/2" pipe size | without valves. | DwyerDS-300-10-LV | Flow sensor | 10" pipe size | without valves. | DwyerDS-300-1-1/2-LV | Flow sensor | 1-1/2" pipe size | without valves. | DwyerDS-300-4 | Flow sensor | 4" pipe size. | DwyerDS-300-1-1/4-LV | Flow sensor | 1-1/4" pipe size | without valves. | DwyerDS-400-16 | Flow sensor | 16" pipe size. | DwyerDS-300-3 | Flow sensor | 3" pipe size. | DwyerDS-400-14-LV | Flow sensor | 14" pipe size | without valves. | DwyerDS-400-14 | Flow sensor | 14" pipe size. | DwyerDS-300-2-1/2 | Flow sensor | 2-1/2" pipe size. | DwyerDS-400-12-LV | Flow sensor | 12" pipe size | without valves. | DwyerDS-300-2 | Flow sensor | 2" pipe size. | DwyerDS-400-12 | Flow sensor | 12" pipe size. | DwyerDS-300-10 | Flow sensor | 10" pipe size. | DwyerDS-400-10-LV | Flow sensor | 10" pipe size | without valves. | DwyerDS-300-1-1/4 | Flow sensor | 1-1/4" pipe size. | DwyerDS-400-10 | Flow sensor | 10" pipe size. | DwyerDS-300-1-1/2 | Flow sensor | 1-1/2" pipe size. | DwyerDS-300-8-LV | Flow sensor | 8" pipe size | without valves. | DwyerDS-300-1 | Flow sensor | 1" pipe size. | DwyerDS-300-6-LV | Flow sensor | 6" pipe size | without valves. | DwyerDS-300-3-LV | Flow sensor | 3" pipe size | without valves. | DwyerDS-300-8 | Flow sensor | 8" pipe size. | DwyerDS-300-6 | Flow sensor | 6" pipe size. | DwyerDFMT2-50A | Remote Digital Flow Transmitter | 2" NPT | DwyerDFMT2-40A | Remote Digital Flow Transmitter | 1-1/2" NPT | DwyerDFMT2-25A | Remote Digital Flow Transmitter | 1" NPT | DwyerDFMT2-20A | Remote Digital Flow Transmitter | 3/4" NPT | DwyerDFMT2-15A | Remote Digital Flow Transmitter | 1/2" NPT | DwyerDFMT2-10A | Remote Digital Flow Transmitter | 3/8" NPT | DwyerDFMT-50A | 2" NPT Digital Flow Transmitter | range 8.8 to 180 GPM (2 to 40.9 m3/h) | DwyerDFMT-40A | 1-1/2" NPT Digital Flow Transmitter | range 6.6 to 105 GPM (1.5 to 23.85 m3/h) | DwyerDFMT-25A | 1" NPT Digital Flow Transmitter | range 2.2 to 50 GPM (0.5 to 11.36 m3/h) | DwyerDFMT-20A | 3/4" NPT Digital Flow Transmitter | range 1.3 to 26 GPM (0.3 to 5.91 m3/h) | DwyerDFMT-15A | 1/2" NPT Digital Flow Transmitter | range 0.9 to 18 GPM (0.2 to 4.09 m3/h) | DwyerDFMT-10A | 3/8" NPT Digital Flow Transmitter | range 0.5 to 8 GPM (0.1 to 2 m3/h) | DwyerSF2-134 | Sight flow meter | range 8.0-60.0 GPM | 24 VDC | 1" female NPT. | DwyerSF2-111 | Sight flow meter | range 4.0-20.0 GPM | 110 VAC | 1/2" female NPT. | DwyerSF11 | Sight flow transmitter | clear polycarbonate cover. | DwyerSF10 | Sight flow transmitter | 316 stainless steel cover. | DwyerSFI-100T-3/4-A711T | Brass sight flow indicator with A-711T sensor | range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT. | DwyerSFI-100T-1/2-A711T | Brass sight flow indicator with A-711T sensor | range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT. | DwyerUBT-24 | 3/4-4" Ultrasonic heat meter with pulse output and Modbus® communications. | DwyerUBT-14 | 3/4-4" Ultrasonic heat meter with pulse output. | DwyerTUF-800-MD | Tenant ultrasonic BTU flowmeter | DN80 pipe size and 40 m3/h permanent flow rate with Modbus® communication | DwyerTUF-320-MD | Tenant ultrasonic BTU flowmeter | DN32 pipe size and 6 m3/h permanent flow rate with Modbus® communication | DwyerTUF-2000-MD | Tenant ultrasonic BTU flowmeter | DN200 pipe size and 200 m3/h permanent flow rate with Modbus® communication | DwyerTUF-150-MD | Tenant ultrasonic BTU flowmeter | DN15 pipe size and 1.5 m3/h permanent flow rate with Modbus® communication | DwyerTUF-1500-MD | Tenant ultrasonic BTU flowmeter | DN150 pipe size and 150 m3/h permanent flow rate with Modbus® communication | DwyerTUF-1250-MD | Tenant ultrasonic BTU flowmeter | DN125 pipe size and 100 m3/h permanent flow rate with Modbus® communication | DwyerTUF-1000-MD | Tenant ultrasonic BTU flowmeter | DN100 pipe size and 60 m3/h permanent flow rate with Modbus® communication | DwyerTUF-650-MD | Tenant ultrasonic BTU flowmeter | DN65 pipe size and 25 m3/h permanent flow rate with Modbus® communication | DwyerTUF-500-MD | Tenant ultrasonic BTU flowmeter | DN50 pipe size and 15 m3/h permanent flow rate with Modbus® communication | DwyerTUF-250-MD | Tenant ultrasonic BTU flowmeter | DN25 pipe size and 3.5 m3/h permanent flow rate with Modbus® communication | DwyerTUF-200-MD | Tenant ultrasonic BTU flowmeter | DN20 pipe size and 2.5 m3/h permanent flow rate with Modbus® communication | DwyerTUF-400-MD | Tenant ultrasonic BTU flowmeter | DN40 pipe size and 10 m3/h permanent flow rate with Modbus® communication | DwyerTUF-2000-BN | Tenant ultrasonic BTU flowmeter | DN200 pipe size and 200 m3/h permanent flow rate with BACnet® communication. | Dwyer