Get Special Pricing!
LC1F265 | UNEQUIPPED CONTAC TO R LC1F 3P AC3 440V. | Square D by Schneider Electric
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1F265
Documents and manuals
Square D LC1F265 Documents
Overview
Details for LC1F265
UNEQUIPPED CONTAC TO R LC1F 3P AC3 440V.
TeSys F contactor, 3 poles (3NO), 265A/1000V AC-3, for motor applications up to 132kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).Specifications
- Range
- TeSys
- Product name
- TeSys F
- Product or component type
- Contactor
- device short name
- LC1F
- contactor application
- Resistive load
Motor control - Utilisation category
- AC-3
AC-4
AC-1 - Poles description
- 3P
- power pole contact composition
- 3 NO
- [Ie] rated operational current
- 350 A (at <40 °C) at <= 440 V AC AC-1
265 A (at <55 °C) at <= 440 V AC AC-3 - Motor power kW
- 132 kW at 380...400 V AC 50/60 Hz (AC-3)
140 kW at 415 V AC 50/60 Hz (AC-3)
140 kW at 440 V AC 50/60 Hz (AC-3)
147 kW at 1000 V AC 50/60 Hz (AC-3)
160 kW at 500 V AC 50/60 Hz (AC-3)
75 kW at 220...240 V AC 50/60 Hz (AC-3)
160 kW at 660...690 V AC 50/60 Hz (AC-3)
51 kW at 400 V AC 50/60 Hz (AC-4) - [Uc] control circuit voltage
- 24...1000 V AC 40...400 Hz with LX1/LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V with LXE coil - [Uimp] rated impulse withstand voltage
- 8 kV
- Overvoltage category
- III
- [Ith] conventional free air thermal current
- 350 A (at 40 °C)
- Irms rated making capacity
- 2650 A AC conforming to IEC 60947-4-1
- Rated breaking capacity
- 2120 A conforming to IEC 60947-4-1
- [Icw] rated short-time withstand current
- 2200 A 40 °C - 10 s
1230 A 40 °C - 30 s
950 A 40 °C - 1 min
620 A 40 °C - 3 min
480 A 40 °C - 10 min - Associated fuse rating
- 315 A aM at <= 440 V
400 A gG at <= 440 V - Average impedance
- 0.3 mOhm - Ith 350 A 50 Hz
- [Ui] rated insulation voltage
- 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C - Power dissipation per pole
- 37 W AC-1
21 W AC-3 - Control circuit voltage limits
- Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.15...0.2 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil - Heat dissipation
- 8 W
2.2…2.5 W - Operating time
- 40...65 ms closing for with LX1/LX9 coil
100...170 ms opening for with LX1/LX9 coil
40...50 ms closing for with LX4 coil
40...65 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil - Mounting support
- Plate
- Standards
- IEC 60947-1
IEC 60947-4-1
JIS C8201-4-1
EN 60947-1
EN 60947-4-1 - product certifications
- ABS
CB
DNV
RMRoS
UL
CSA
RINA
LROS (Lloyds register of shipping)
BV
UKCA - Connections - terminals
- Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm
Power circuit: lugs-ring terminals 1 cable(s) 240 mm²
Power circuit: connector 1 cable(s) 240 mm²
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end - Tightening torque
- Power circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m - Mechanical durability
- 10 Mcycles
- Inrush power in VA
- 600…700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
655…803 VA (at 20 °C)with LX4 coil
300…350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
300…310 VA (at 20 °C)with LXE coil - Hold-in power consumption in VA
- 8…10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
3.68…4.53 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil - Maximum operating rate
- 2400 cyc/h 55 °C
- Compatibility code
- LC1F
- [Ue] rated operational voltage
- <= 1000 V AC-1
<= 690 V AC-3
<= 690 V AC-4
<= 460 V DC - IP degree of protection
- IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106 - Protective treatment
- TH
- Ambient air temperature for operation
- -5…55 °C
- Ambient air temperature for storage
- -60…80 °C
- Permissible ambient air temperature around the device
- -40…70 °C
- Operating altitude
- 3000 m without derating
- Mechanical robustness
- Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) - Height
- 203 mm
- Width
- 201.5 mm
- Depth
- 213 mm
- Net weight
- 8.54 kg
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 25.000 cm
- Package 1 Width
- 25.000 cm
- Package 1 Length
- 28.000 cm
- Package 1 Weight
- 7.159 kg
- Unit Type of Package 2
- P06
- Number of Units in Package 2
- 12
- Package 2 Height
- 75.000 cm
- Package 2 Width
- 60.000 cm
- Package 2 Length
- 80.000 cm
- Package 2 Weight
- 95.140 kg
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
171CBU98090 | UNITY M1E SERIAL 232/485 | Square D by Schneider Electric
Brand: Square D
SKU: 171CBU980902601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D by Schneider Electric
Brand: Square D
SKU: 2601AG28911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO42V099001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G3People Also Searched
LC1F265
Square D LC1F265
LC1F265 price
Square D LC1F265 price