XPSUAK12AP | Safety module, Harmony Safety Automation, Cat.4, features XPSUAF + PNP/NPN, safety mat, 24v AC/DC, screw | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: XPSUAK12AP

Web Price:

$212.05
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

XPSUAK12AP | Safety module, Harmony Safety Automation, Cat.4, features XPSUAF + PNP/NPN, safety mat, 24v AC/DC, screw | Square D by Schneider Electric

Square D | XPSUAK12AP
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to XPSUAK12AP

Documents and manuals

Square D XPSUAK12AP Documents

Overview

Details for XPSUAK12AP

Safety module, Harmony Safety Automation, Cat.4, features XPSUAF + PNP/NPN, safety mat, 24v AC/DC, screw

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP, NPN sensors, RFID safety switch, Safety light curtain or Sensing mat/edges. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 2 NO + 1 NC safety outputs, and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILC L 3 conforming to IEC 62061, and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.

Specifications

Range of Product
Harmony Safety Automation
Product or Component Type
Safety module
Safety module name
XPSUAK
Safety module application
Monitoring antivalent contacts, For emergency stop, guard and light curtain monitoring, Monitoring of pressure-sensitive 4-wire protective devices
Function of module
Emergency stop button with 2 NC contacts, Guard monitoring with 1 or 2 limit switches, Monitoring 2 PNP sensors, Magnetic switch monitoring, Light curtain monitoring, RFID switch, Monitoring of electro-sensitive protection equipment (ESPE), Sensing mat/edges, Proximity sensor monitoring, Monitoring 1 PNP + 1 NPN sensor
safety level
Can reach PL e/category 4 for normally open relay contact ISO 13849-1, Can reach SILCL 3 for normally open relay contact IEC 62061, Can reach SIL 3 for normally open relay contact IEC 61508, Can reach PL c/category 1 for normally closed relay contact ISO 13849-1, Can reach SILCL 1 for normally closed relay contact IEC 62061, Can reach SIL 1 for normally closed relay contact IEC 61508
safety reliability data
MTTFd > 30 years ISO 13849-1, Dcavg >= 99 % ISO 13849-1, PFHd = 1.13E-09 ISO 13849-1, HFT = 1 IEC 62061, PFHd = 1.13E-09 IEC 62061, SFF > 99% IEC 62061, HFT = 1 IEC 61508-1, PFHd = 1.13E-09 IEC 61508-1, SFF > 99% IEC 61508-1, Type = B IEC 61508-1
Electrical circuit type
NC pair, PNP pair, Antivalent pair, OSSD pair
connections - terminals
Removable screw terminal block, 0.2...2.5 mm² solid or flexible, Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor, Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor, Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel, Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] Rated Supply Voltage
24 V AC - 15...10 %, 24 V DC - 20...20 %
Synchronisation time between inputs
0.5 s, 2 s, 4 s
Type of start
Automatic/manual/monitored
power consumption in W
2.0 W 24 V DC
power consumption in VA
5.0 VA 24 V AC 50/60 Hz
Input protection type
Internal, electronic
safety outputs
2 NO + 1 NC
safety inputs
2
maximum wire resistance
500 Ohm
input compatibility
Normally closed circuit ISO 14119, XC limit switch ISO 14119, Mechanical contact ISO 14119, Normally closed circuit ISO 13850, Antivalent pair ISO 14119, OSSD pair IEC 61496-1-2, 3-wire proximity sensors PNP
[Ie] rated operational current
5 A AC-1, 3 A AC-15, 5 A DC-1, 3 A DC-13, 3 A AC-1, 1 A AC-15, 3 A DC-1, 1 A DC-13
control outputs
3 pulsed output
input/output type
Semiconductor pulsed diagnostic output Z1, 20 mA
[Ith] conventional free air thermal current
8 A
associated fuse rating
10 A gG NO relay output circuit IEC 60947-1
minimum output current
10 mA relay output
minimum output voltage
12 V relay output
[Ui] rated insulation voltage
250 V 2)EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
4 kV II EN/IEC 60947-1
Mounting Support
35 mm symmetrical DIN rail
Depth
4.72 in (120 mm)
Height
3.94 in (100 mm)
Width
0.89 in (22.5 mm)
Net Weight
0.44 lb(US) (0.200 kg)
Ambient Air Temperature for Operation
-13…131 °F (-25…55 °C)
standards
IEC 60947-5-1, IEC 61508-1 functional safety standard, IEC 61508-2 functional safety standard, IEC 61508-3 functional safety standard, IEC 61508-4 functional safety standard, IEC 61508-5 functional safety standard, IEC 61508-6 functional safety standard, IEC 61508-7 functional safety standard, ISO 13849-1 functional safety standard, IEC 62061 functional safety standard
Product Certifications
TÜV, cULus
IP degree of protection
IP20 terminals)EN/IEC 60529, IP40 housing)EN/IEC 60529, IP54 mounting area)EN/IEC 60529
Relative Humidity
5…95 % non-condensing
Category
22477-SAFETY MODULES (PREVENTA)
Discount Schedule
SAF2
GTIN
3606489601652
Returnability
Yes
Country of origin
ID
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.56 in (6.500 cm)
Package 1 Width
5.31 in (13.500 cm)
Package 1 Length
6.10 in (15.500 cm)
Package 1 Weight
9.66 oz (274 g)
Unit Type of Package 2
S03
Number of Units in Package 2
16
Package 2 Height
11.81 in (30.000 cm)
Package 2 Width
11.81 in (30.000 cm)
Package 2 Length
15.75 in (40.000 cm)
Package 2 Weight
11.43 lb(US) (5.186 kg)
Unit Type of Package 3
P06
Number of Units in Package 3
128
Package 3 Height
29.53 in (75.000 cm)
Package 3 Width
23.62 in (60.000 cm)
Package 3 Length
31.50 in (80.000 cm)
Package 3 Weight
110.95 lb(US) (50.324 kg)