Overview

Details for LR9F5571

DISCONTINUED MODEL, CONTACT TECHNICAL SUPPORT FOR REPLACEMENT OPTIONS

TeSys LRF Electronic Thermal Overload Relay, Class 20, 1 NO + 1NC, 132-220A, IP20

TeSys LRF Thermal Overload Relay:
  • Thermal Overload Class: Class 20
  • Thermal Protection Adjustment Range: 132A to 220A
  • Contacts Type and Composition: 1 NO + 1 NC
  • Conventional Free Air Thermal Current: 5A for control circuit
  • Rated Operational Voltage: 1000V AC 50/60 Hz for power circuit conforming to VDE 0110 group C
  • Rated Insulation Voltage: 1000 V AC power circuit conforming to IEC 60947-4
  • Control Type: Dial white full-load current adjustment, Test button red, Push-button red reset, Push-button stop
  • Degree of Protection: IP20 conforming to IEC 60529 and VDE 0106
TeSys LR9F electronic overload relay, thermal setting range 132-220A, class 20, for protection of motors 90-110kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F185, F225, F265, use of a support mounting plate LA7F901 is recommended (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop & reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs/Reach).

Specifications

range
TeSys
product name
TeSys LRF
device short name
LR9F
Product or Component Type
Electronic thermal overload relay
relay application
Motor protection
Product Compatibility
LC1F185...LC1F265
network type
AC
thermal overload class
Class 20 IEC 60947-4
thermal protection adjustment range
132…220 A
Network Frequency
50/60 Hz
mounting support
Direct on contactor;Plate
tripping threshold
1.12 +/- 0.06 In tripping IEC 60947-4-1
surge withstand
4 kV IEC 61000-4-5
contacts type and composition
1 NO + 1 NC
[Ith] conventional free air thermal current
5 A control circuit
[Ue] rated operational voltage
1000 V AC 50/60 Hz power circuit VDE 0110 group C
[Ui] rated insulation voltage
Power circuit 1000 V AC IEC 60947-4
[Uimp] rated impulse withstand voltage
8 kV IEC 60947-1
phase failure sensitivity
Tripping in 4 s +/- 20 % IEC 60947-4-1
reset
Manual reset on front relay
control type
Dial White full-load current adjustment;Test button Red;Push-button reset;Push-button Red stop
local signalling
Trip indicator
temperature compensation
-4…158 °F (-20…70 °C)
current consumption
<= 5 mA no-load
switching capacity for alarm
0...150 mA
maximum voltage drop
<2.5 V closed state
connections - terminals
Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) flexible - with cable end;Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) solid;Control circuit screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²) flexible - without cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…1.5 mm²) flexible - with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible - without cable end;Control circuit screw clamp terminals 2 0.00 in² (1 mm²) solid;Power circuit lugs-ring terminals M10
tightening torque
Control circuit 1.2 N.m screw clamp terminals;Power circuit 35 N.m screw clamp terminals
Height
3.98 in (101 mm)
Width
4.53 in (115 mm)
Depth
4.86 in (123.5 mm)
Net Weight
2.09 lb(US) (0.95 kg)
Standards
IEC 60255-8;EN 60947-4-1;IEC 60255-17;IEC 60947-4-1;VDE 0660
Product Certifications
CSA;UL;UKCA
protective treatment
TH
IP degree of protection
IP20 conforming to IEC 60529;IP20 conforming to VDE 0106
ambient air temperature for operation
-4…131 °F (-20…55 °C) IEC 60255-8
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
operating altitude
<= 6561.68 ft (2000 m) without derating
fire resistance
1562 °F (850 °C) IEC 60695-2-1
mechanical robustness
Shocks13 Gn for 11 ms IEC 60068-2-7;Vibrations 5...300 Hz2 GN IEC 60068-2-6
dielectric strength
6 kV 50 Hz IEC 255-5
electromagnetic compatibility
Resistance to electrostatic discharge 6 kV in indirect mode IEC 61000-4-2;Resistance to electrostatic discharge 8 kV in air IEC 61000-4-2;Radiated radio-frequency electromagnetic field immunity test 10 V/m IEC 61000-4-3;Fast transients immunity test 2 kV IEC 61000-4-4
Category
22334-CONTACTOR;F-LINE;OVERLOADS
Discount Schedule
I12
GTIN
3389110640205
Returnability
Yes
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.12 in (13.0 cm)
Package 1 Width
5.91 in (15.0 cm)
Package 1 Length
6.30 in (16.0 cm)
Package 1 Weight
2.25 lb(US) (1.02 kg)
Unit Type of Package 2
S04
Number of Units in Package 2
11
Package 2 Height
11.81 in (30.0 cm)
Package 2 Width
15.75 in (40.0 cm)
Package 2 Length
23.62 in (60.0 cm)
Package 2 Weight
26.68 lb(US) (12.1 kg)
Warranty
18 months