TeSys LRF Electronic Thermal Overload Relay, Class 10, 1 NO + 1NC, 90-150A, IP20
TeSys LRF Thermal Overload Relay:- Thermal Overload Class: Class 20
- Thermal Protection Adjustment Range: 90A to 150A
- Contacts Type and Composition: 1 NO + 1 NC
- Conventional Free Air Thermal Current: 5A for control circuit
- Rated Operational Voltage: 1000V AC 50/60 Hz for power circuit conforming to VDE 0110 group C
- Rated Insulation Voltage: 1000 V AC power circuit conforming to IEC 60947-4
- Control Type: Dial white full-load current adjustment, Test button red, Push-button red reset, Push-button stop
- Degree of Protection: IP20 conforming to IEC 60529 and VDE 0106
Specifications
- range
- TeSys
- product name
- TeSys LRF
- device short name
- LR9F
- Product or Component Type
- Electronic thermal overload relay
- relay application
- Motor protection
- Product Compatibility
- LC1F115...LC1F185
- network type
- AC
- thermal overload class
- Class 20 IEC 60947-4
- thermal protection adjustment range
- 90…150 A
- Network Frequency
- 50/60 Hz
- mounting support
- Direct on contactor;Plate
- tripping threshold
- 1.12 +/- 0.06 In tripping IEC 60947-4-1
- surge withstand
- 4 kV IEC 61000-4-5
- contacts type and composition
- 1 NO + 1 NC
- [Ith] conventional free air thermal current
- 5 A control circuit
- [Ue] rated operational voltage
- 1000 V AC 50/60 Hz power circuit VDE 0110 group C
- [Ui] rated insulation voltage
- Power circuit 1000 V AC IEC 60947-4
- [Uimp] rated impulse withstand voltage
- 8 kV IEC 60947-1
- phase failure sensitivity
- Tripping in 4 s +/- 20 % IEC 60947-4-1
- reset
- Manual reset on front relay
- control type
- Dial White full-load current adjustment;Test button Red;Push-button Red reset;Push-button stop
- local signalling
- Trip indicator
- temperature compensation
- -4…158 °F (-20…70 °C)
- current consumption
- <= 5 mA no-load
- switching capacity for alarm
- 0...150 mA
- maximum voltage drop
- <2.5 V closed state
- connections - terminals
- Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) flexible - with cable end;Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) solid;Control circuit screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²) flexible - without cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…1.5 mm²) flexible - with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible - without cable end;Control circuit screw clamp terminals 2 0.00 in² (1 mm²) solid;Power circuit lugs-ring terminals M8
- tightening torque
- Control circuit 1.2 N.m screw clamp terminals;Power circuit 18 N.m screw clamp terminals
- Height
- 3.78 in (96 mm)
- Width
- 4.53 in (115 mm)
- Depth
- 4.86 in (123.5 mm)
- Net Weight
- 1.95 lb(US) (0.885 kg)
- Standards
- IEC 60255-17;EN 60947-4-1;IEC 60255-8;VDE 0660;IEC 60947-4-1
- Product Certifications
- CSA;UL;UKCA
- protective treatment
- TH
- IP degree of protection
- IP20 conforming to IEC 60529;IP20 conforming to VDE 0106
- ambient air temperature for operation
- -4…131 °F (-20…55 °C) IEC 60255-8
- Ambient Air Temperature for Storage
- -40…185 °F (-40…85 °C)
- operating altitude
- <= 6561.68 ft (2000 m) without derating
- fire resistance
- 1562 °F (850 °C) IEC 60695-2-1
- mechanical robustness
- Shocks13 Gn for 11 ms IEC 60068-2-7;Vibrations 5...300 Hz2 GN IEC 60068-2-6
- dielectric strength
- 6 kV 50 Hz IEC 255-5
- electromagnetic compatibility
- Resistance to electrostatic discharge 6 kV in indirect mode IEC 61000-4-2;Resistance to electrostatic discharge 8 kV in air IEC 61000-4-2;Radiated radio-frequency electromagnetic field immunity test 10 V/m IEC 61000-4-3;Fast transients immunity test 2 kV IEC 61000-4-4
- Category
- 22334-CONTACTOR;F-LINE;OVERLOADS
- Discount Schedule
- I12
- GTIN
- 3389110640199
- Returnability
- Yes
- Country of origin
- FR
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 5.12 in (13.0 cm)
- Package 1 Width
- 5.91 in (15.0 cm)
- Package 1 Length
- 6.30 in (16.0 cm)
- Package 1 Weight
- 30.41 oz (862.0 g)
- Unit Type of Package 2
- S04
- Number of Units in Package 2
- 12
- Package 2 Height
- 11.81 in (30.0 cm)
- Package 2 Width
- 15.75 in (40.0 cm)
- Package 2 Length
- 23.62 in (60.0 cm)
- Package 2 Weight
- 24.24 lb(US) (10.996 kg)
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
171CBU98090 | UNITY M1E SERIAL 232/485 | Square D by Schneider Electric
Brand: Square D
SKU: 171CBU980902601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D by Schneider Electric
Brand: Square D
SKU: 2601AG28911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO42V099001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G3People Also Searched
LR9F5569
Square D LR9F5569
LR9F5569 price
Square D LR9F5569 price