Sitemap

Pages

Brands

Products

607-8 | Differential pressure transmitter | range 0-10" w.c. | Dwyer607-7B | Differential pressure transmitter | range 5.0-0-5.0" w.c. | Dwyer607-9 | Differential pressure transmitter | range 0-25" w.c. | Dwyer605-0 | Differential pressure indicating transmitter | range 0-.50" w.c. | max. pressure 10 psi (1.7 bar) | ±2% electrical accuracy | ±3% mechanical accuracy. | Dwyer607-71 | Differential pressure transmitter | range 0-5.0" w.c. | Dwyer607-7 | Differential pressure transmitter | range 0-5.0" w.c. | Dwyer607-2B | Differential pressure transmitter | range .50-0-.50" w.c. | Dwyer607-3 | Differential pressure transmitter | range 0-1.0" w.c. | Dwyer607-21 | Differential pressure transmitter | range 0-.50" w.c. | Dwyer607-4B | Differential pressure transmitter | range 2.0-0-2.0" w.c. | Dwyer607-4 | Differential pressure transmitter | range 0-2.0" w.c. | Dwyer607-3B | Differential pressure transmitter | range 1.0-0-1.0" w.c. | Dwyer607-11 | Differential pressure transmitter | range 0-.25" w.c. | Dwyer607-1B | Differential pressure transmitter | range .25-0-.25" w.c. | Dwyer607-0B | Differential pressure transmitter | range .10-0-.10" w.c. | Dwyer607-1 | Differential pressure transmitter | range 0-.25" w.c. | Dwyer607-2 | Differential pressure transmitter | range 0-.50" w.c. | Dwyer607-01 | Differential pressure transmitter | range 0-.10" w.c. | DwyerMS-922-LCD | Differential pressure transmitter | 5V output | 12V input | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | duct mount | with LCD. | Dwyer (OBSOLETE)MS-922 | Differential pressure transmitter | 5V output | 12V input | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | duct mount. | Dwyer (OBSOLETE)607-0 | Differential pressure transmitter | range 0-.10" w.c. | DwyerMS-921-LCD | Differential pressure transmitter | 5V output | 12V input | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-912-LCD | MS-912 Differential pressure transmitter | 5V output | 12V input | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | duct mount | with LCD. | Dwyer (OBSOLETE)MS-912 | Differential pressure transmitter | 5V output | 12V input | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | duct mount. | Dwyer (OBSOLETE)MS-921 | Differential pressure transmitter | 5V output | 12V input | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | wall mount. | Dwyer (OBSOLETE)MS-911-LCD | Differential pressure transmitter | 5V output | 12V input | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-821-LCD | Differential pressure transmitter | 5V output | 12V input | selectable range ±0.1" | 0.25" | 0.5" w.c. (±25 | 50 | 100 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-821 | Differential pressure transmitter | 5V output | 12V input | selectable range ±0.1" | 0.25" | 0.5" w.c. (±25 | 50 | 100 Pa) | wall mount. | Dwyer (OBSOLETE)MS-911 | Differential pressure transmitter | 5V output | 12V input | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | wall mount. | Dwyer (OBSOLETE)MS-722-LCD | Differential pressure transmitter | 5 VDC output | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | duct mount | with LCD. | Dwyer (OBSOLETE)MS-721-LCD | Differential pressure transmitter | 5 VDC output | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-721 | Differential pressure transmitter | 5 VDC output | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | wall mount. | Dwyer (OBSOLETE)MS-712-LCD | Differential pressure transmitter | 5V output | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | duct mount | with LCD. | Dwyer (OBSOLETE)MS-711-LCD | Differential pressure transmitter | 5 VDC output | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-621-LCD | Differential pressure transmitter | 5 VDC output | selectable range ±0.1" | 0.25" | 0.5" w.c. (±25 | 50 | 100 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-322-LCD | Differential pressure transmitter | 0-10 V output | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | duct mount | with LCD. | Dwyer (OBSOLETE)MS-711 | Differential pressure transmitter | 5 VDC output | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | wall mount. | Dwyer (OBSOLETE)MS-321 | Differential pressure transmitter | 0-10 V output | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | wall mount. | Dwyer (OBSOLETE)MS-322 | Differential pressure transmitter | 0-10 V output | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | duct mount. | Dwyer (OBSOLETE)MS-321-LCD | Differential pressure transmitter | 0-10 V output | selectable range 0.1" | 0.25" | 0.5" w.c. (25 | 50 | 100 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-621 | Differential pressure transmitter | 5 VDC output | selectable range ±0.1" | 0.25" | 0.5" w.c. (±25 | 50 | 100 Pa) | wall mount. | Dwyer (OBSOLETE)MS-312 | Differential pressure transmitter | 0-10 V output | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | duct mount. | Dwyer (OBSOLETE)MS-311-LCD | Differential pressure transmitter | 0-10 V output | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)MS-311 | Differential pressure transmitter | 0-10 V output | selectable range 1" | 2" | 5" w.c. (250 | 500 | 1250 Pa) | wall mount. | Dwyer (OBSOLETE)MS-221-LCD | Differential pressure transmitter | 0-10 V output | selectable range ±0.1" | 0.25" | 0.5" w.c. (±25 | 50 | 100 Pa) | wall mount | with LCD. | Dwyer (OBSOLETE)EWDP-08-2-L-N | EnOcean®-Enabled Differential Pressure Switch | .08-1.2" w.c. | M20x1.5 connection | low voltage gold plated | 902 MHz | DwyerMS-131-LCD | Differential pressure transmitter | 4-20 mA output | selectable range 10" w.c. (2 kPa) | wall mount | with LCD. | Dwyer (OBSOLETE)DXW-11-153-4 | Differential pressure switch | brass and fluoroelastomer wetted materials | NEMA 4X | 1/4" NPT connections | SPDT | range 50 to 75 psi. | DwyerEWDP-07-2-L-N | EnOcean®-Enabled Differential Pressure Switch | 4-20" w.c. | M20x1.5 connection | low voltage gold plated | 902 MHz | DwyerBDPA-08-2-N | Adjustable differential pressure alarm | range .08-1.20" w.c. | M20 connection. | DwyerEWDP-04-2-L-N-C | EnOcean®-Enabled Differential Pressure Switch | .12-1.61" w.c. | M20x1.5 connection with installer kit | low voltage gold plated | 902 MHz | DwyerEWDP-04-2-L-N | EnOcean®-Enabled Differential Pressure Switch | .12-1.61" w.c. | M20x1.5 connection | low voltage gold plated | 902 MHz | DwyerDXW-11-153-3 | Differential pressure switch | brass and fluoroelastomer wetted materials | NEMA 4X | 1/4" NPT connections | SPDT | range 25 to 50 psi. | DwyerBDPA-07-2-N | Adjustable differential pressure alarm | range 4.00-20.00" w.c. | M20 connection. | DwyerBDPA-05-2-N | Adjustable differential pressure alarm | range .80-4.00" w.c. | M20 connection. | DwyerBDPA-04-2-N | Adjustable differential pressure alarm | range .12-1.60" w.c. | M20 connection. | DwyerBDPA-03-2-N | Adjustable differential pressure alarm | range .20-2.00" w.c. | M20 connection. | DwyerA3000-1.5KPA | Pressure switch/gage | range 0-1.5 kPa. | DwyerBDPA-06-2-N | Adjustable differential pressure alarm | range 2.00-10.00" w.c. | M20 connection. | DwyerEDPS-07-1-N | Adjustable differential pressure switch | range 4.00-20.00" w.c. | with 1/2" NPT connection. | DwyerEDPS-06-1-N | Adjustable differential pressure switch | range 2.00-10.00" w.c. | with 1/2" NPT connection. | DwyerEDPS-08-1-N | Adjustable differential pressure switch | range .08-1.20" w.c. | with 1/2" NPT connection. | DwyerEDPS-08-2-N | Adjustable differential pressure switch | range .08-1.20" w.c. | with M20 connection. | DwyerEDPS-05-1-N | Adjustable differential pressure switch | range .80-4.00" w.c. | with 1/2" NPT connection. | DwyerADPS-08-2-N-C | Adjustable differential pressure switch | set point range 0.08 to 1.20" w.c. | M20 connection | with two static tips and 7 ft (2.1 m) of PVC tubing. | DwyerEDPS-06-2-N | Adjustable differential pressure switch | range 2.00-10.00" w.c. | with M20 connection. | DwyerADPS-08-2-N | Adjustable differential pressure switch | set point range 0.08 to 1.20" w.c. | M20 connection. | DwyerEDPS-05-2-N | Adjustable differential pressure switch | range .80-4.00" w.c. | with M20 connection. | DwyerADPS-07-2-N-C | Adjustable differential pressure switch | set point range 4.00 to 20.00" w.c. | M20 connection | with two static tips and 7 ft (2.1 m) of PVC tubing. | DwyerADPS-07-2-N | Adjustable differential pressure switch | set point range 4.00 to 20.00" w.c. | M20 connection. | DwyerADPS-05-2-N-C | Adjustable differential pressure switch | set point range 0.80 to 4.00" w.c. | M20 connection | with two static tips and 7 ft (2.1 m) of PVC tubing. | DwyerADPS-07-1-N | Adjustable differential pressure switch | set point range 4.00 to 20.00" w.c. | 1/2" NPT connection. | DwyerADPS-06-1-N | Adjustable differential pressure switch | set point range 2.00 to 10.00" w.c. | 1/2" NPT connection. | DwyerADPS-06-2-N-C | Adjustable differential pressure switch | set point range 2.00 to 10.00" w.c. | M20 connection | with two static tips and 7 ft (2.1 m) of PVC tubing. | DwyerADPS-05-1-N | Adjustable differential pressure switch | set point range 0.80 to 4.00" w.c. | 1/2" NPT connection. | DwyerA4-5 | Differential pressure switch | ±32 psi (2.2 bar) repeatability | set point (increasing) 120-250 psid (8.3-17.2 bar) | set point (decreasing) 35-120 psid (2.4-8.3 bar). | DwyerADPS-06-2-N | Adjustable differential pressure switch | set point range 2.00 to 10.00" w.c. | M20 connection. | DwyerADPS-05-2-N | Adjustable differential pressure switch | set point range 0.80 to 4.00" w.c. | M20 connection. | DwyerA4-3 | Differential pressure switch | ±8 psi (.55 bar) repeatability | set point (increasing) 25-45 psid (1.7-3.1 bar) | set point (decreasing) 10-21 psid (.68-1.5 bar). | DwyerA4-4 | Differential pressure switch | ±16 psi (1.1 bar) repeatability | set point (increasing) 35-160 psid (2.4-11.0 bar) | set point (decreasing) 20-80 psid (1.4-5.5 bar). | DwyerA4-1 | Differential pressure switch | ±2 psi (.14 bar) repeatability | set point (increasing) 7-13 psid (.48-.89 bar) | set point (decreasing) 2-7 psid (.14-.48 bar). | DwyerMDA-211 | Miniature adjustable pressure switch | min. set point 2.0" w.c. (4.98 mbar) | max. set point 15" w.c. (37.37 mbar). | DwyerMDA-411 | Miniature adjustable pressure switch | min. set point 60" water (149.3 mbar) | max. set point 100" water (249.10 mbar). | DwyerMDA-111 | Miniature adjustable pressure switch | min. set point 0.5" w.c. (1.25 mbar) | max. set point 2.0" w.c. (4.98 mbar). | DwyerMDA-311 | Miniature adjustable pressure switch | min. set point 15" w.c. (37.37 mbar) | max. set point 60" w.c. (149.3 mbar). | DwyerMDS-14 | Miniature pressure switch | set point 50.0" H2O. | DwyerMDS-12 | Miniature pressure switch | set point 30.0" H2O. | DwyerMDA-011-T | Miniature adjustable pressure switch | min. set point 0.1" w.c. (0.25 mbar) | max. set point 0.5" w.c. (1.25 mbar). | DwyerMDS-8 | Miniature pressure switch | set point 10.0" H2O. | DwyerMDS-7 | Miniature pressure switch | set point 8.0" H2O. | DwyerMDS-10 | Miniature pressure switch | set point 15.0" H2O. | DwyerMDS-4 | Miniature pressure switch | set point 3.0" H2O. | DwyerMDS-6 | Miniature pressure switch | set point 6.0" H2O. | DwyerMDS-3 | Miniature pressure switch | set point 2.0" H2O. | DwyerMDS-2 | Miniature pressure switch | set point 1.5" H2O. | DwyerPG-7000-153-P2 | Gas pressure/differential pressure switch | range 0.5-5 psid (.03-.345 bar) | max. deadband .5 psid (.035 bar) | SPDT snap switch. | DwyerMDS-0 | Miniature pressure switch | set point 0.5" H2O. | Dwyer1996-5 | Gas pressure switch | range 1.4-5.5" w.c. | DwyerMDS-1 | Miniature pressure switch | set point 1.0" H2O. | DwyerPG-7000-153-P1 | Gas pressure/differential pressure switch | range 1-30" water (.25-7.47 kPa) | max. deadband 4" w.c. (1.0 kPa) | SPDT snap switch. | DwyerPG-3-P2 | Gas pressure/differential pressure switch | range 0.5-5 psid (.03-.345 bar) | max. deadband 0.3 psid (0.21 kPa) | SPST mercury switch | closes on increase. | Dwyer1996-20 | Gas pressure switch | range 4-20" w.c. | DwyerPG-3-P1 | Gas pressure/differential pressure switch | range 1-30" water (.25-7.47 kPa) | max. deadband 1.3" w.c. (0.32 kPa) | SPST mercury switch | closes on increase. | DwyerPG-153-P2 | Gas pressure/differential pressure switch | range 0.5-5 psid (.03-.345 bar) | max. deadband 0.4 psid (0.38 bar) | SPDT mercury switch. | DwyerPG-153-P1 | Gas pressure/differential pressure switch | range 1-30" water (.25-7.47 kPa) | max. deadband 1.9" w.c. (0.47 kPa) | SPDT mercury switch. | DwyerDPA-7043-153-62E | Differential pressure switch | 316SS bellows | range 0-20 psid (0-1.4 bar) | max. pressure 100 psig (6.9 bar) | min. deadband 3.0 psid (.21 bar). | DwyerDPA-7033-153-64 | Differential pressure switch | brass bellows | range 0-30 psid (0-2.1 bar) | max. pressure 300 psig (20.7 bar) | min. deadband 6.0 psid (.41 bar). | DwyerDPA-7033-153-61 | Differential pressure switch | brass bellows | range 0-10 psid (0-0.7 bar) | max. pressure 50 psig (3.5 bar) | min. deadband 1.5 psid (.10 bar). | DwyerDPA-7043-153-64E | Differential pressure switch | 316SS bellows | range 0-30 psid (0-2.1 bar) | max. pressure 300 psig (20.7 bar) | min. deadband 6.0 psid (.41 bar) | DwyerDPA-43-153-64E | Differential pressure switch | 316SS bellows | range 0-30 psid (0-2.1 bar) | max. pressure 300 psig (20.7 bar) | min. deadband 3.5 psid (.24 bar). | DwyerDPA-7033-153-62 | Differential pressure switch | brass bellows | range 0-20 psid (0-1.4 bar) | max. pressure 100 psig (6.9 bar) | min. deadband 2.5 psid (.17 bar). | DwyerDPA-43-153-62E | Differential pressure switch | 316SS bellows | range 0-20 psid (0-1.4 bar) | max. pressure 100 psig (6.9 bar) | min. deadband 2.0 psid (.14 bar). | DwyerDPA-33-153-62 | Differential pressure switch | brass bellows | range 0-20 psid (0-1.4 bar) | max. pressure 100 psig (6.9 bar) | min. deadband 1.5 psid (.10 bar). | DwyerDPA-33-153-64 | Differential pressure switch | brass bellows | range 0-30 psid (0-2.1 bar) | max. pressure 300 psig (20.7 bar) | min. deadband 3.0 psid (.21 bar). | DwyerDPA-33-153-61 | Differential pressure switch | brass bellows | range 0-10 psid (0-0.7 bar) | max. pressure 50 psig (3.5 bar) | min. deadband 1.0 psid (.07 bar). | Dwyer1640-2 | Floating contact switch | range 1.0-4.0" w.c. | adj. span | .03 min. set | .12 max. Set. | Dwyer1640-10 | Floating contact switch | range 3.0-12.0" w.c. | adj. span | .04 min. set | .20 max. Set. | Dwyer1640-5 | Floating contact switch | range 2.0-6.0" w.c. | adj. span | .03 min. set | .18 max. Set. | Dwyer1640-1 | Floating contact switch | range 0.2-1.0" w.c. | adj. span | .02 min. set | .06 max. Set. | Dwyer1638-5 | Large diaphragm pressure switch | range 2.0-6.0" w.c. | approx deadband @ 0.07 min. set point | 0.25 max. set point. | Dwyer1640-0 | Floating contact switch | range .01-0.2" w.c. | adj. span | .01 min. set | .03 max. Set. | Dwyer1638-2 | Large diaphragm pressure switch | range 1.0-3.0" w.c. | approx deadband @ 0.06 min. set point | 0.08 max. set point. | Dwyer1638-10 | Large diaphragm pressure switch | range 3.0-12" w.c. | approx deadband @ 0.11 min. set point | 0.30 max. set point. | Dwyer1638-1 | Large diaphragm pressure switch | range 0.20-1.0" w.c. | approx deadband @ 0.04 min. set point | 0.06 max. set point. | Dwyer1638-0 | Large diaphragm pressure switch | range 0.05-0.25" w.c. | approx deadband @ 0.04 min. set point | 0.05 max. set point. | Dwyer1626-20 | Single and dual pressure switch | range 8.0-24" w.c. | .50 min. deadband | 1.20 max. deadband | 5.0 adj. diff. between set points. | Dwyer1626-10 | Single and dual pressure switch | range 2.0-11" w.c. | .25 min. deadband | .65 max. deadband | 2.3 adj. diff. between set points. | Dwyer1626-5 | Single and dual pressure switch | range .5-6.0" w.c. | .15 min. deadband | .35 max. deadband | 1.2 adj. diff. between set points. | Dwyer1950G-20-B-24-NA | Explosion-proof differential pressure switch | range 4-20" w.c. | approx. deadband @ min. set point 1.2 | approx. deadband @ max. set point 3.0. | Dwyer1950G-5-B-120-NA | Explosion-proof differential pressure switch | range 1.4-5.5" w.c. | approx. deadband @ min. set point .4 | approx. deadband @ max. set point .9. | Dwyer1950G-5-B-24-NA | Explosion-proof differential pressure switch | range 1.4-5.5" w.c. | approx. deadband @ min. set point .4 | approx. deadband @ max. set point .9. | Dwyer1950G-20-B-120-NA | Explosion-proof differential pressure switch | range 4-20" w.c. | approx. deadband @ min. set point 1.2 | approx. deadband @ max. set point 3.0. | Dwyer1626-1 | Single and dual pressure switch | range .15-1.5" w.c. | .10 min. deadband | .20 max. deadband | 0.5 adj. diff. between set points. | Dwyer1950G-10-B-120-NA | Explosion-proof differential pressure switch | range 3-11" w.c. | approx. deadband @ min. set point .9 | approx. deadband @ max. set point 1.8. | Dwyer1950G-1-B-24-NA | Explosion-proof differential pressure switch | range .4-1.6" w.c. | approx. deadband @ min. set point .11 | approx. deadband @ max. set point .29. | Dwyer1950G-1-B-120-NA | Explosion-proof differential pressure switch | range .4-1.6" w.c. | approx. deadband @ min. set point .11 | approx. deadband @ max. set point .29 | Dwyer1950G-10-B-24-NA | Explosion-proof differential pressure switch | range 3-11" w.c. | approx. deadband @ min. set point .9 | approx. deadband @ max. set point 1.8. | Dwyer1950P-8-2F | Differential pressure switch | range 1.5-8 psid | approx. deadband @ min. set point 1.0 | approx. deadband @ max. set point 1.0. | Dwyer1950G-0-B-120-NA | Explosion-proof differential pressure switch | range .15-.50" w.c. | approx. deadband @ min. set point .06 | approx. deadband @ max. set point .11. | Dwyer1950P-50-2F | Differential pressure switch | range 15-50 psid | approx. deadband @ min. set point 1.0 | approx. deadband @ max. set point 1.5. | Dwyer1950P-25-2F | Differential pressure switch | range 4-25 psid | approx. deadband @ min. set point 0.7 | approx. deadband @ max. set point 0.7. | Dwyer1950P-2-2F | Differential pressure switch | range 0.5-2 psid | approx. deadband @ min. set point 0.3 | approx. deadband @ max. set point 0.3. | Dwyer1950P-15-2F | Differential pressure switch | range 3-15 psid | approx. deadband @ min. set point 0.9 | approx. deadband @ max. set point 0.9. | Dwyer1950-5-2F | Differential pressure switch | range 1.4-5.5" w.c. | approx. deadband @ min. set point 0.30 | approx. deadband @ max. set point 0.40. | Dwyer1910-20 | Differential pressure switch | range 4.0-20.0" w.c. | approx. deadband @ min. set point 0.40 | approx. deadband @ max. set point 0.50. | Dwyer1910-10 | Differential pressure switch | range 3.0-11.75" w.c. | approx. deadband @ min. set point 0.40 | approx. deadband @ max. set point 0.40. | Dwyer1950-20-2F | Differential pressure switch | range 4-20" w.c. | approx. deadband @ min. set point 0.40 | approx. deadband @ max. set point 0.60. | Dwyer1950-10-2F | Differential pressure switch | range 3-11" w.c. | approx. deadband @ min. set point 0.40 | approx. deadband @ max. set point 0.50. | Dwyer1910-1 | Differential pressure switch | range 0.40-1.6" w.c. | approx. deadband @ min. set point 0.15 | approx. deadband @ max. set point 0.16. | Dwyer1910-0 | Differential pressure switch | range 0.15-0.5" w.c. | approx. deadband @ min. set point 0.10 | approx. deadband @ max. set point 0.10. | Dwyer1823-80 | Differential pressure switch | range 9-85" w.c. | approx. deadband @ min. set point 1.30 | approx. deadband @ max. set point 3.0. | Dwyer1900-10-MR | Differential pressure switch | range 3.0-11.75" w.c. | approx. deadband @ min. set point 0.40 | approx. deadband @ max. set point 0.40 | with manual reset option. | Dwyer1823-20 | Differential pressure switch | range 3-22" w.c. | approx. deadband @ min. set point 0.35 | approx. deadband @ max. set point 0.70. | Dwyer1823-2 | Differential pressure switch | range 0.5-2.0" w.c. | approx. deadband @ min. set point 0.10 | approx. deadband @ max. set point 0.12. | Dwyer1823-10 | Differential pressure switch | range 2.0-10" w.c. | approx. deadband @ min. set point 0.18 | approx. deadband @ max. set point 0.45. | Dwyer1823-5 | Differential pressure switch | range 1.5-5.0" w.c. | approx. deadband @ min. set point 0.14 | approx. deadband @ max. set point 0.28. | Dwyer1823-1 | Differential pressure switch | range 0.3-1.0" w.c. | approx. deadband @ min. set point 0.08 | approx. deadband @ max. set point 0.08. | Dwyer1823-0 | Differential pressure switch | range 0.15-.5" w.c. | approx. deadband @ min. set point 0.06 | approx. deadband @ max. set point 0.06. | Dwyer1823-40 | Differential pressure switch | range 5-44" w.c. | approx. deadband @ min. set point 0.56 | approx. deadband @ max. set point 1.10. | DwyerDHII-017 | Differential pressure controller | range 10-0-10" w.c. NOTE: velocity & volumetric flow not available. | DwyerDHII-015 | Differential pressure controller | range 2.5-0-2.5" w.c. NOTE: velocity & volumetric flow not available. | DwyerDHII-012 | Differential pressure controller | range 0-25-0-0.25" w.c. NOTE: velocity & volumetric flow not available. | DwyerDHII-016 | Differential pressure controller | range 5-0-5" w.c. NOTE: velocity & volumetric flow not available. | DwyerDHII-014 | Differential pressure controller | range 1.0-0-1.0" w.c. NOTE: velocity & volumetric flow not available. | DwyerDHII-007 | Differential pressure controller | selectable engineering units: 10.00" w.c. | .8333 ft w.c. | 254.0 mm w.c. | 25.40 cm w.c. | .3613 psi | .7356" Hg | 18.68 mm Hg | 24.91 mbar | 2491 Pa | 2.491 kPa | 24.91 hPa | 5.780 oz/in². | DwyerDHII-002 | Differential pressure controller | selectable engineering units: .2500" w.c. | 6.350 mm w.c. | 0.635 cm w.c. | 0.467 mm Hg | 0.623 mbar | 62.28 Pa | 0.623 hPa | 0.114 oz/in². | DwyerDHC-206 | Differential pressure controller | range ±2.5 in w.c. | DwyerDHC-209 | Differential pressure controller | range ±10 in w.c. | DwyerDHII-006 | Differential pressure controller | selectable engineering units: 5.000" w.c. | .4167 ft w.c. | 127.0 mm w.c. | 12.70 cm w.c. | .1806 psi | .3678" Hg | 9.342 mm Hg | 12.45 mbar | 1245 Pa | 1.245 kPa | 12.45 hPa | 2.890 oz/in². | DwyerDHC-204 | Differential pressure controller | range ±1.0 in w.c. | DwyerDHII-004 | Differential pressure controller | selectable engineering units: 1.000" w.c. | 25.40 mm w.c. | 1.868 mm Hg | 2.491 mbar | 249.1 Pa | 0.249 kPa | 2.491 hPa | 0.578 oz/in². | DwyerDHC-202 | Differential pressure controller | range ±0.25 in w.c. | DwyerDHC-012 | Differential pressure controller | range 100 in w.c. | DwyerDHC-003 | Differential pressure controller | range 0.5 in w.c. | DwyerDHC-006 | Differential pressure controller | range 2.5 in w.c. | DwyerDH-016 | Differential pressure controller | range 5-0-5" w.c. NOTE: velocity & volumetric flow not available. | DwyerDHC-002 | Differential pressure controller | range 0.25 in w.c. | DwyerDH-017 | Differential pressure controller | range 10-0-10" w.c. NOTE: velocity & volumetric flow not available. | DwyerDH-014 | Differential pressure controller | range 1.0-0-1.0" w.c. NOTE: velocity & volumetric flow not available. | DwyerDH-015 | Differential pressure controller | range 2.5-0-2.5" w.c. NOTE: velocity & volumetric flow not available. | DwyerDH-008 | Differential pressure controller | selectable engineering units: 25.00" w.c. | 2.083 ft w.c. | 635.0 mm w.c. | 63.50 cm w.c. | .9032 psi | 1.839" Hg | 46.71 mm Hg | 62.27 mbar | 6227 Pa | 6.227 kPa | 62.27 hPa | 14.45 oz/in². | DwyerDH-007 | Differential pressure controller | selectable engineering units: 10.00" w.c. | .8333 ft w.c. | 254.0 mm w.c. | 25.40 cm w.c. | .3613 psi | .7356" Hg | 18.68 mm Hg | 24.91 mbar | 2491 Pa | 2.491 kPa | 24.91 hPa | 5.780 oz/in². | DwyerDH-012 | Differential pressure controller | range 0-25-0-0.25" w.c. NOTE: velocity & volumetric flow not available. | DwyerDH-006 | Differential pressure controller | selectable engineering units: 5.000" w.c. | .4167 ft w.c. | 127.0 mm w.c. | 12.70 cm w.c. | .1806 psi | .3678" Hg | 9.342 mm Hg | 12.45 mbar | 1245 Pa | 1.245 kPa | 12.45 hPa | 2.890 oz/in². | DwyerDH-002 | Differential pressure controller | selectable engineering units: .2500" w.c. | 6.350 mm w.c. | 0.635 cm w.c. | 0.467 mm Hg | 0.623 mbar | 62.28 Pa | 0.623 hPa | 0.114 oz/in². | DwyerDH-004 | Differential pressure controller | selectable engineering units: 1.000" w.c. | 25.40 mm w.c. | 1.868 mm Hg | 2.491 mbar | 249.1 Pa | 0.249 kPa | 2.491 hPa | 0.578 oz/in². | DwyerA3310 | Pressure switch/gage | range 5-0-5" w.c. | DwyerA3304 | Pressure switch/gage | range 2-0-2" w.c. | DwyerA3330 | Pressure switch/gage | range 15-0-15" w.c. | DwyerA3301 | Pressure switch/gage | range .5-0-.5" w.c. | DwyerA3302 | Pressure switch/gage | range 1-0-1" w.c. | DwyerA3320 | Pressure switch/gage | range 10-0-10" w.c. | DwyerA3300-500PA | Pressure switch/gage | range 250-0-250 Pa. | DwyerA3300-3KPA | Pressure switch/gage | range 1.5-0-1.5 kPa. | DwyerA3300-30MM | Pressure switch/gage | range 15-0-15 mm w.c. | DwyerA3300-1KPA | Pressure switch/gage | range .5-0-.5 kPa. | DwyerA3300-20MM | Pressure switch/gage | range 10-0-10 mm w.c. | DwyerA3300-250PA | Pressure switch/gage | range 125-0-125 Pa. | DwyerA3220 | Pressure switch/gage | range 0-20 psi | medium pressure option standard. | DwyerA3300-0 | Pressure switch/gage | range .25-0-.25" w.c. | Dwyer