U020-0011 | Flow | Mag | 10 in | H-rubb | Grd Rng | Rmt Amp | Veris
Electromagnetic Flow Meter, 10 in Flange
Overview Details for U020-0011
Electromagnetic (mag) flow meters are capable of measuring flow in almost any liquid, slurry or paste with a minimum of electrical conductivity using Faraday's law of induction. These meters are highly accurate, at 0.25% or better, exceeding AWWA accuracy standards for mechanical meters. The smart, micro-processor based electronics are simple to operate, with AMR and SCADA ready standard outputs. The NEMA 4X enclosure provides durability.
- Reliable, durable design - open flow tube design, no head loss, no moving parts to fail
- 0.25% accuracy independent of fluid viscosity, density, and temperature
- Bi-directional flow measurement capability, suitable for inter-city billing
- Password security - protect against unwanted program changes
- Wide flow range - exceeds operating characteristics of turbine and propeller meters
- Works with most solids common in liquid systems, great for well water and reclaimed water systems, not fouled by sand, gravel, or debris
- Flow direction - uni-directional or bidirectional, two separate totalizers (programmable)
- Coil power - pulsed DC
- Powder coated die-cast aluminum junction box
- 4 to 20 mA, 0 to 20 mA, 0 to 10 mA, 2 to 10 mA (programmable and scalable); voltage sourced 24 VDC (isolated); maximum loop resistance less than 800 Ohm analog outputs
- Four total, configurable 24 VDC sourcing active output (up to two), 100 mA total, 50 mA each; sinking open collector output (up to four), 30 VDC maximum, 100 mA each; AC solid-state relay (up to two), 48 VAC, 500 mA maximum digital outputs
- Scalable up to 10 kHz, passive open collector up to 10 kHz, active switched 24 VDC, up to two outputs (forward and reverse) pulse width programmable from 1 to 1100 ms or 50% duty cycle pulse outputs
Electromagnetic (mag) flow meters are capable of measuring flow in almost any liquid, slurry or paste with a minimum of electrical conductivity using Faraday's law of induction. These meters are highly accurate, at 0.25% or better, exceeding AWWA accuracy standards for mechanical meters. The smart, micro-processor based electronics are simple to operate, with AMR and SCADA ready standard outputs. The NEMA 4X enclosure provides durability.
- Reliable, durable design - open flow tube design, no head loss, no moving parts to fail
- 0.25% accuracy independent of fluid viscosity, density, and temperature
- Bi-directional flow measurement capability, suitable for inter-city billing
- Password security - protect against unwanted program changes
- Wide flow range - exceeds operating characteristics of turbine and propeller meters
- Works with most solids common in liquid systems, great for well water and reclaimed water systems, not fouled by sand, gravel, or debris
- Flow direction - uni-directional or bidirectional, two separate totalizers (programmable)
- Coil power - pulsed DC
- Powder coated die-cast aluminum junction box
- 4 to 20 mA, 0 to 20 mA, 0 to 10 mA, 2 to 10 mA (programmable and scalable); voltage sourced 24 VDC (isolated); maximum loop resistance less than 800 Ohm analog outputs
- Four total, configurable 24 VDC sourcing active output (up to two), 100 mA total, 50 mA each; sinking open collector output (up to four), 30 VDC maximum, 100 mA each; AC solid-state relay (up to two), 48 VAC, 500 mA maximum digital outputs
- Scalable up to 10 kHz, passive open collector up to 10 kHz, active switched 24 VDC, up to two outputs (forward and reverse) pulse width programmable from 1 to 1100 ms or 50% duty cycle pulse outputs
Specifications
Item Number | U020-0011 |
Brand | Veris |
Application | Flow |
Display Type | LCD |
Field Programmable | Yes |
Fitting Material | Steel | Rubber |
Fitting Size | 10" |
Fitting Type | Flange |
Flow Measurement Accuracy | ±0.2% |
Flow Measurement Range | 0.1 - 39.4 ft/s (0.03 - 12 m/s) |
Flow Measurement Repeatability | ±0.1% |
Flow Sensor Type | Electromagnetic |
IP Protection | IP66 (NEMA 4) |
Liner Material | Hard Rubber |
Measurement Type | Flow |
Medium | Water based liquids |
Meter Type | Electromagnetic (Mag) |
Model | M2-100-R1-A-RAF-S-XXXF |
Operating Fluid Temperature | 32 - 178 °F (0 - 80 °C) |
Operating Temperature | 32 - 178 °F (0 - 80 °C) |
Output Specifications | 4 - 20 mA | 0 - 20 mA | 0 - 10 mA | 2 - 10 mA | 1 ms - 1.1 s Scaled Pulse |
Outputs | Analog output | Pulse output |
Pipe Material | Copper | Polymer | Steel | Stainless Steel |
Product Certification | NSF |
Product Type | Sensor |
Range | M2000 ModMAG Series |
Totalizer Quantities | 2 |
Totalizer Resettable | Yes |
Warranty | 1 year |