E30C242 | 42-ckt solid-core BrCur meter | 100A CTs | 18mm spacing | Veris
100 A 90 to 277 VAC Line-to-Neutral, 300 VAC Circuit Multi-Circuit Basic Panelboard Monitoring System, Solid-Core, 42-Circuit with 18 mm Spacing
Overview Details for E30C242
The E30 series panel board monitoring system provides a cost effective solution for electrical load management, making it ideally suited for applications where loads are dynamic, such as the data storage industry, lighting panels, etc. The E30 series monitors the current, voltage, instantaneous power, demand and energy consumption of each circuit in a panel board including the main feed. As a circuit approaches the user configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.
- Revenue grade - ANSI and IEC Class 1 metering system accuracy including branch CTs
- Widest dynamic range in the industry, 50 mA to 100 A monitoring
- Versatility - flexible installation with 18 mm spaced solid-core branch CT strips
- New construction and retrofit applications
The E30 series panel board monitoring system provides a cost effective solution for electrical load management, making it ideally suited for applications where loads are dynamic, such as the data storage industry, lighting panels, etc. The E30 series monitors the current, voltage, instantaneous power, demand and energy consumption of each circuit in a panel board including the main feed. As a circuit approaches the user configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.
- Revenue grade - ANSI and IEC Class 1 metering system accuracy including branch CTs
- Widest dynamic range in the industry, 50 mA to 100 A monitoring
- Versatility - flexible installation with 18 mm spaced solid-core branch CT strips
- New construction and retrofit applications
Specifications
Item Number | E30C242 |
Brand | Veris |
Accuracy | 1% System; +/-0.5% of Reading 90 to 277 VAC Line-to-Neutral Voltage; +/-0.5% of Reading from Current |
Communication | ModBus (RTU) |
Dimensions | 8.9" (226 mm) W x 5.8" (146 mm) L |
Environmental Conditions | Humidity Range: Less Than 95% RH Non-Condensing; Storage Temperature: -40 to 158 °F; Altitude of Operation: 3000 m |
Feature Level | Current Only |
Frequency Rating | 50 - 60 Hz |
Metering Product Family | E30 Panel Meter |
Monitored Voltage Range | 90 - 277 VAC; Line to Neutral |
Mounting | Solid-Core |
Operating Temperature | 32 - 140 °F |
Output Specifications | Modbus RTU;2 or 4 wire; RS485 |
Power Monitoring | Branch Current Monitor - Solid Core |
Product Type | Panelboard Monitoring System; Multi-Circuit; Basic |
Range | E30 |