TABKIT-NIST | Complete NIST calibrated Test | Adjust and Balance Kit with a hard carrying case. | Dwyer
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!

Web Price:

$8,971.42
Availability: This product is currently available to purchase

Contact us for price breaks on large quantities!

Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs. Shipping and Returns Terms
Ship to Estimates
Are you from Chicago?
Yes / No
This item ships to
Change
Cancel


*shipping cost are estimated until you complete your order

The product is not cancelable or returnable unless found defective

Speak With a Technical Expert

Image for Technical Expert

TABKIT-NIST | Complete NIST calibrated Test | Adjust and Balance Kit with a hard carrying case. | Dwyer

Complete NIST calibrated Test, Adjust and Balance Kit with a hard carrying case.

Brand: DwyerSKU: TABKIT-NIST
Dwyer | TABKIT-NIST
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to TABKIT-NIST

Overview Details for TABKIT-NIST

See catalog product page for full listing

Complete NIST calibrated Test | Adjust and Balance Kit with a hard carrying case.

SERIES TABKIT TEST, ADJUST, AND BALANCE KIT

A Complete Balancing Technician Solution

The Series TABKIT Test, Adjust, and Balance Kit combines all essential air, water,temperature, humidity, and electrical test instruments are included in this kit, creatingthe ultimate air and water balancing solution. The Series TABKIT has everything abalancing technician needs in a single case. A certificate of NIST calibration is includedfor each instrument inside the kit, ensuring accurate, durable, repeatable, and reliablemeasurements every time. When the products need to be recalibrated, save time bysending everything back to Dwyer. Our lab is able to service all equipment within thekit, and ensure they’re as accurate as the day you originally received them.


Complete Kit Includes:

  • Model 160G Averaging Air Flow Grid
  • Model DP3 Bluetooth-Enabled Wireless Differential Pressure Module
  • Model AP3 Bluetooth-Enabled Wireless Thermo-Anemometer Probe
  • Model RP3 Bluetooth-Enabled Wireless Thermo-Hygrometer Probe
  • Model VP3 Bluetooth-Enabled Wireless 100 mm Vane Thermo-Anemometer Probe
  • Model TAC-L Portable Digital Tachometer
  • Model CM-1 Digital Clamp Meter
  • Series 490W Wireless Hydronic Differential Pressure Manometer
  • Model 160F 18" Straight Stainless Steel Pitot Tube
  • Model 160-18 18" Stainless Steel Pitot Tube
  • Two Model A-303 Static Pressure Tips with Magnetic Mounting
  • Cooper-Atkins Model TM99A Thermistor Temperature Instrument
  • Cooper-Atkins Model 1075 General Purpose Puncture Probe
  • Hard Case


California Residents:  Click Here for Proposition 65 WARNING.

Product Applications

  • Building balancing
  • Building commissioning
  • Testing HVAC equipment performance
  • Everything a balancing technician needs in a single case
  • Best in class low flow velocity readings
  • Repeatable measurements

Specifications

Series
TABKIT TEST; ADJUST; AND BALANCE KIT
Category/Type
Test Equipment
Type
HVAC Balancing Instruments
Series
TABKIT TEST; ADJUST; AND BALANCE KIT
AIR
Series DP3
Accuracy*
±0.5% FS span @ 25°C(includes non linearity; hysteresis; and nonrepeatability).
Pressure Limits
±10 in w.c. (±2.5 kPa).
Temperature Limits
Operating: -4 to140°F (-20 to 60°C); Storage: -40 to 185°F(-40 to 85°C).
Model AP3
Range
Air velocity: 0 to 6000 FPM (0 to 30 m/s); Volumetric air: 999;999 in selected flow units; Temperature: -20 to212°F (-29 to 100°C).
Accuracy
Air velocity*: ±3% FS withintemperature range of 40 to 90°F (4 to32°C) -TAB option: 50 to 3900 FPM (0.25to 20 m/s); Temperature: ±0.5°F (±0.28°C).
Model VP3
Range
Air velocity: 40 to 5000 FPM (0.2to 25 m/s); Volumetric air: 999;999 inselected flow units; Temperature: -20 to212°F (-29 to 100°C); Relative humidity: 0to 100% RH.
Accuracy
Air velocity*: 0.25 to 10m/s: ±1.5% of reading ±20 FPM (±0.1m/s); 10 to 20 m/s: 1.5% of reading±40 FPM (±0.2 m/s); 20 to 25 m/s:±1.5% of reading ±60 FPM (±0.3 m/s);Temperature: ±0.54°F @ 77°F (±0.3°C@ 25°C); Relative humidity: ±2% @ 77°F(25°C) (10 to 90% RH); ±4% (0 to 10% RHand 90 to 100%).
Resolution
1 FPM (0.001 m/s).
TEMPERATURE
TM99A and 1075
Range
0 to 200°F (-20 to 100°C).
Accuracy*
±0.5% of reading + 2.0°F (±0.5% of reading + 1.0°C).
Resolution
0.1°F (0.1°C).
HUMIDITY
Model RP3
Range
RH: 0 to 100% (noncondensing);Temperature: -22 to 140°F(-30 to 60°C).
Accuracy
RH*: ±2% @ 25°C (10 to90% RH); ±4% (0 to 10; 90 to 100% RH);Temperature: ±0.54°F @ 77°F (±0.3°C).
ELECTRICAL
Model CM-1
AC Voltage
0.1-600 V ± (1.0% + 5 dgt).
DC Voltage
0.1-600 V ± (1.0% + 3 dgt).
AC Current
0.1-400 A ± (2.0% + 10 dgt).
Resistance
0.1-400 Ω ± (1.0% + 5 dgt).
ROTATION
Model TAC-L
Range
Non-contact (RPM): 2.5 to99;999 RPM; Contact (RPM): 0.5 to19;999 RPM; Surface speed (m/min):0.05 to 19;999 m/min.
Resolution
Non-contact* (RPM): 0.1RPM (2.5 to 999.9 RPM); 1 RPM (1000to 19;000 RPM); Surface speed (m/min):0.01 m/min (0.05 to 99.99 m/min); 0.1 m/min (100.0 to 1999.9 m/min).
HYDRONIC
A-490W-6
Range
0.4 to 200 psi; 3 to 1400 kPa. 0.4 to 75 psi; 3 to 500 kPa.
Accuracy
2% of reading ±1 psi; 2% of reading ±7 kPa. 2% of reading ±0.5 psi; 2% of reading ±3.5 kPa.
Resolution
0.1 psi; 1.0 kPa. 0.01 psi; 0.1 kPa.
*NIST calibrated.

Reviews