Overview Details for SE8350U5B00
Low-Voltage Fan Coil Room Controller & Zone Controller: BACnet MS/TP, RH sensor & control, PIR motion sensor, Silver Case/Fascia
This SE8350 Low Voltage fan coil unit and zone room controller. With touch color screen. Silver Fascia & Casing. PIR motion sensor. BACnet communication to connect with BMS.Specifications
- Product name
- SE8000 Series
- device short name
- SE8300
- Product or component type
- Room controller
- device application
- Low voltage fan coil
- Net weight
- 340 g
- AWG gauge
- AWG 24...AWG 18
- Targeted region
- North America.
- Height
- 120 mm
- Width
- 86 mm
- Temperature resolution
- 0.1 °C
- Humidity measurement drift
- Less than 1 % yearly
- directives
- 2014/30/EU - electromagnetic compatibility
2014/35/EU - low voltage directive
2014/53/EU - radio equipment directive - [In] rated current
- 4 A
- Depth
- 25 mm
- Ambient air temperature for operation
- 0…50 °C
- Market segment
- Lodging/hotel
Small commercial
Buildings
Healthcare
Non-critical buildings
Office
Residential
School - Housing colour
- Silver
- Ambient air temperature for storage
- -30…50 °C
- Measurement accuracy
- Temperature: +/- 0.5 °C,
Humidity: +/- 5 %, 20...80 % RH (non-condensing)
Humidity: +/- 10 %, 10...20 % (non-condensing)
Humidity: +/- 10 %, 80...90 % (non-condensing) - Information displayed
- Temperature: - 40...122 °F
- Network frequency
- 50 Hz
60 Hz - communication port protocol
- BACnet MS/TP
Modbus RTU - Input voltage
- 0...10 V DC
- Temperature setting range
- 12…37.5 °C cooling
4.5…32 °C heating - Calibration certificate
- 1 pt
- Output voltage
- 24 V AC for relay output
0...10 V DC for analog output - Relative humidity
- 0…95 %
- Output current
- 1 A relay output
3 A relay output (inrush)
0.3 A universal output
1.5 A universal output (inrush) - Input type
- 2 x dry contact
5 x analog - Sensor type
- 10 kOhm T2 NTC thermistor temperature
Space RH sensor humidity
Bulk polymer humidity - Output type
- 5 xrelay output
4 xuniversal - [Us] rated supply voltage
- 24 V AC 50/60 Hz +/- 15 %
- Standards
- EN/IEC 60730-1
FCC part 15 Subpart B
ICES-003
ETSI EN 300 328
ETSI EN 301 489-1:v1.9.2
FCC part 15 Subpart C
UL 60730-2-9
ETSI EN 301 489-17:v2.2.1, 2012 - Humidity setting range
- 30…95 %
- Range
- EcoStruxure Building Expert
- Economizer
- Yes
- Humidity control
- Yes
- PIR cover
- Yes
- Scheduling
- No
- Surface finish
- Matt
- Surface treatment
- Untreated
- Function available
- Fan control
HVAC control
Available with CO2/RH/T
Brightness sensor
Changes can be made directly over display
Code lock function
Easily configurable
Firmware update by USB - Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 4.7 cm
- Package 1 Width
- 10.6 cm
- Package 1 Length
- 15.2 cm
- Package 1 Weight
- 253 g