MC6    | Benchtop calibrator.  |   Dwyer
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: DwyerSKU: MC6

Web Price:

$4,860.68
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
The product is not cancelable or returnable unless found defective
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

MC6 | Benchtop calibrator. | Dwyer

Benchtop calibrator.

Dwyer | MC6
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to MC6

Documents and manuals

Dwyer MC6 Documents

Overview

Details for MC6

See catalog product page for full listing

Benchtop calibrator.

MODEL MC6 MULTI-CAL BENCHTOP CALIBRATOR

Interchangeable Ranges, ±0.05% Accuracy, Data Logging Capability, NIST Traceable

Model MC6 Multi-Cal Benchtop Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility. Calibrator can accommodate up to two interchangeable pressure modules (sold separately) in any combination of range or accuracy.

Simultaneously display two separate measurements on the two line, alphanumeric display. Readings can be displayed in a choice of twelve preprogrammed engineering units or any single user-defined unit. Calibrator features min/max recall, hi/lo alarm, percentage of full scale pressure readings, mA/voltage measurement, leak rate and pressure decay measurement, switch testing capabilities, including trip point and dead band, and velocity/volume flow rates.

Quickly document calibration procedures using the data logging feature which stores up to 384 sets of pressure and time/date stamped measurements. The automatic % error calculation simplifies transmitter calibration. Easily upload stored data to an IBM compatible computer via the RS232 two-way communications port. Calibrators and modules include certification to NIST traceability--ideal as a secondary standard for calibrating pressure equipment.

Multi-Cal Pressure Calibrator includes utility software, protection module, adjustment handle, AC adapter, and instruction manual.

Multi-Cal Pressure Modules are interchangeable and available in a wide selection of pressure ranges and accuracies (contact customer service for additional ranges). Benchtop calibrator accepts up to two pressure modules. Modules include NIST calibration certification.

Product Applications

  • Clean Room Control
  • Filter Performance Monitoring
  • HVAC Testing and Setup
  • Draft Measurement
  • Airflow Measurement Control
  • Differential Pressure Measurement in Laminar Flowhoods
  • Paint Booths
  • Industrial Ovens and Fume Hoods
  • Use as a Secondary Standard for Calibrating Pressure Equipment

Specifications

Service
Clean; dry; nonconductive; noncorrosive gases.
Accuracy
Differential Pressure Modules: ±0.06% FS; Gage Pressure Modules: ±0.05% FS; Voltage Input: ±0.025% FS @ 1/10 VDC; ±0.10% FS @ 0/30 VDC; Current Input: ±0.03% FS @ 1/20 mA; ±0.05% FS @ 0/50 mA.
Sensitivity
±0.002% of span with dampening 1 part in 50;000 (max.).
Repeatability
Ranges ≤0/2 psi: ±0.05% of span; Ranges ≥0/5 psid: ±0.02% of span.
Output
RS232 serial interface; 9-pin.
Alarm Output
SPST form C 110 VDC; 120 VDC (max.); 1 A (mas.); 30 W; 62.5 VA (resistive).
Display
Alphanumeric LCD; 0.37" (9.5 mm) height per line; 2 lines; 16 characters/line.
Display Update
100 ms.
Ambient Operation Temperature
32 to 120°F (0 to 49°C).
Storage Temperature
-4 to 158°F (-20 to 70°C).
Process Connection
1/8" female NPT.
Electrical Connections
Standard banana jacks.
Power Supply
110 VAC/60 Hz adapter; 500 mA.
Memory Backup Requirements:
VL1220 or BR1225 Lithium Metal battery; installed functional; user replaceable.
Engineering Units
In H2O; psi; in Hg; kPa; mbar; bar; cm H2O; mm Hg; ft SW; MPa; mm H2O; kg cm² and user-defined.
Overpressure
Differential Pressure Modules: 50 psi positive direction; 15 psi negative direction; Gage Pressure Modules: 2x range (0/5 psi to 0/1000 psi).
Temperature Compensation
20 to 120°F (-7 to 49°C).
Temperature Error
Maximum of ±0.004% of span per °F over compensated range for zero and span.
Temperature Effect Electrical Measurement
±0.001% of span per °F over compensated range.
Dampening
(Measurement averaging) programmable from 0 to 16 consecutive readings.
Baud Rate
300; 1200; 2400; or 9600; selectable.
Computer Requirements
IBM compatible 386 or above and Windows® 3.1 or later with 2MB RAM and 2MB hard drive disk space; one serial port.
Housing Material
ABS plastic.
Weight
Calibrator: 3 lb (1.4 kg); Pressure Module: 0.5 lb (0.3 kg).