LC1K1210F7 | TeSys K Contactor, 3-Poles (3 NO), 1 NO Aux. Contact, 12A, 110V AC Coil, Non-Reversing | Square D by Schneider Electric
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!

Web Price:

$102.12
Availability: This product is currently available to purchase

Contact us for price breaks on large quantities!

Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs. Shipping and Returns Terms
Ship to Estimates
Are you from Chicago?
Yes / No
This item ships to
Change
Cancel


*shipping cost are estimated until you complete your order

Speak With a Technical Expert

Image for Technical Expert

Documents: LC1K1210F7

LC1K1210F7 | TeSys K Contactor, 3-Poles (3 NO), 1 NO Aux. Contact, 12A, 110V AC Coil, Non-Reversing | Square D by Schneider Electric

Brand: Square DSKU: LC1K1210F7
Square D | LC1K1210F7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1K1210F7

Overview Details for LC1K1210F7

TeSys K Contactor, 3-Poles (3 NO), 1 NO Aux. Contact, 12A, 110V AC Coil, Non-Reversing

TeSys K Contactor
  • Number of Poles: 3-Poles
  • Pole Contact Composition: 3 NO
  • Auxilliary Contact Composition: 1 NO
  • Rated Operational Current: 12A
  • Control Circuit Voltage: 110V AC 50/60 Hz
  • Non-Reversing LC1K1210F7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 110V 50/60Hz AC coil and 1NO auxiliary contact. LC1K1210F7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 110V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
  • Specifications

    range
    TeSys
    Product or Component Type
    Contactor
    product name
    TeSys K
    device short name
    LC1K
    Device Application
    Control
    contactor application
    Resistive load;Motor control
    utilisation category
    AC-3;AC-4;AC-1;AC-3e
    poles description
    3P
    power pole contact composition
    3 NO
    [Ue] rated operational voltage
    Power circuit 690 V AC 50/60 Hz;Signalling circuit <= 690 V AC 50/60 Hz
    [Ie] rated operational current
    20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit;12 A<= 440 V AC AC-3 power circuit;16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit;12 A<= 440 V AC AC-3e power circuit
    control circuit type
    AC 50/60 Hz
    [Uc] control circuit voltage
    110 V AC 50/60 Hz
    motor power kW
    4 kW 480 V AC 50/60 Hz AC-3;4 kW 500...600 V AC 50/60 Hz AC-3;4 kW 660...690 V AC 50/60 Hz AC-3;2.2 kW 400 V AC 50/60 Hz AC-4;3 kW 220...230 V AC 50/60 Hz AC-3;5.5 kW 380...415 V AC 50/60 Hz AC-3;5.5 kW 440 V AC 50/60 Hz AC-3;4 kW 480 V AC 50/60 Hz AC-3e;4 kW 500...600 V AC 50/60 Hz AC-3e;4 kW 660...690 V AC 50/60 Hz AC-3e;3 kW 220...230 V AC 50/60 Hz AC-3e;5.5 kW 380...415 V AC 50/60 Hz AC-3e;5.5 kW 440 V AC 50/60 Hz AC-3e
    auxiliary contact composition
    1 NO
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    20 A 122 °F (50 °C) power circuit;10 A 122 °F (50 °C) signalling circuit
    Irms rated making capacity
    110 A AC signalling circuit IEC 60947;144 A AC power circuit NF C 63-110;144 A AC power circuit IEC 60947
    rated breaking capacity
    110 A 440 V IEC 60947;80 A 500 V IEC 60947;70 A 660...690 V IEC 60947
    [Icw] rated short-time withstand current
    115 A 122 °F (50 °C) - 1 s power circuit;105 A 122 °F (50 °C) - 5 s power circuit;100 A 122 °F (50 °C) - 10 s power circuit;75 A 122 °F (50 °C) - 30 s power circuit;55 A 122 °F (50 °C) - 1 min power circuit;50 A 122 °F (50 °C) - 3 min power circuit;80 A - 1 s signalling circuit;90 A - 500 ms signalling circuit;110 A - 100 ms signalling circuit;25 A 122 °F (50 °C) - >= 15 min power circuit
    associated fuse rating
    25 A gG <= 440 V power circuit;25 A aM power circuit;10 A gG signalling circuit IEC 60947;10 A gG signalling circuit VDE 0660
    average impedance
    3 mOhm - Ith 20 A 50 Hz power circuit
    [Ui] rated insulation voltage
    Power circuit 600 V UL 508;Power circuit 690 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-5-1;Signalling circuit 600 V UL 508;Power circuit 600 V CSA C22.2 No 14;Signalling circuit 600 V CSA C22.2 No 14
    insulation resistance
    > 10 MOhm signalling circuit
    inrush power in VA
    30 VA 68 °F (20 °C))
    hold-in power consumption in VA
    4.5 VA 68 °F (20 °C))
    heat dissipation
    1.3 W
    control circuit voltage limits
    Operational 0.8...1.15 Uc 122 °F (50 °C));Drop-out 0.2...0.75 Uc 122 °F (50 °C))
    connections - terminals
    screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid;screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end;screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end;screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid;screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end;screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
    maximum operating rate
    3600 cyc/h
    auxiliary contacts type
    Instantaneous 1 NO
    signalling circuit frequency
    <= 400 Hz
    minimum switching current
    5 mA signalling circuit
    minimum switching voltage
    17 V signalling circuit
    Mounting Support
    Rail;Plate
    tightening torque
    7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2;7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm;7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
    operating time
    10...20 ms coil de-energisation and NO opening;10...20 ms coil energisation and NO closing
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    non overlap distance
    0.02 in (0.5 mm)
    mechanical durability
    10 Mcycles
    electrical durability
    0.3 Mcycles 20 A AC-1 <= 440 V;1.3 Mcycles 12 A AC-3 <= 440 V;1.3 Mcycles 12 A AC-3e <= 440 V
    mechanical robustness
    Shocks contactor closed;on X axis10 Gn for 11 ms IEC 60068-2-27;Shocks contactor closed;on Y axis15 Gn for 11 ms IEC 60068-2-27;Shocks contactor closed;on Z axis15 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on X axis6 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on Y axis10 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on Z axis10 Gn for 11 ms IEC 60068-2-27;Vibrations contactor closed4 Gn;5...300 Hz IEC 60068-2-6;Vibrations contactor opened2 Gn;5...300 Hz IEC 60068-2-6
    Height
    2.28 in (58 mm)
    Width
    1.77 in (45 mm)
    Depth
    2.24 in (57 mm)
    Net Weight
    0.40 lb(US) (0.18 kg)
    standards
    BS 5424;IEC 60947;NF C 63-110;VDE 0660
    Product Certifications
    CSA;UL;UKCA
    IP degree of protection
    IP2x VDE 0106
    protective treatment
    TC IEC 60068;TC DIN 50016
    Ambient Air Temperature for Storage
    -58…176 °F (-50…80 °C)
    operating altitude
    6561.68 ft (2000 m) without derating
    flame retardance
    V1 conforming to UL 94;Requirement 2 conforming to NF F 16-101;Requirement 2 conforming to NF F 16-102
    Category
    22326-CTR;K-LINE;AC;OPEN;NONREV
    Discount Schedule
    I12
    GTIN
    3389110789751
    Returnability
    Yes
    Country of origin
    ID
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Height
    2.56 in (6.5 cm)
    Package 1 Width
    1.89 in (4.8 cm)
    Package 1 Length
    2.44 in (6.2 cm)
    Package 1 Weight
    6.35 oz (180.0 g)
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    50
    Package 2 Height
    5.91 in (15 cm)
    Package 2 Width
    11.81 in (30 cm)
    Package 2 Length
    15.75 in (40 cm)
    Package 2 Weight
    20.53 lb(US) (9.313 kg)
    Package 3 Height
    30.31 in (77 cm)
    Warranty
    18 months

    Reviews