LC1D150M7 | TeSys D contactor, 3P(3 NO), AC-3, <= 440 V 150 A, 220 V AC 50/60 Hz coil | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: LC1D150M7

Web Price:

$745.31
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

LC1D150M7 | TeSys D contactor, 3P(3 NO), AC-3, <= 440 V 150 A, 220 V AC 50/60 Hz coil | Square D by Schneider Electric

Square D | LC1D150M7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1D150M7

Documents and manuals

Square D LC1D150M7 Documents

Overview

Details for LC1D150M7

TeSys D contactor, 3P(3 NO), AC-3, <= 440 V 150 A, 220 V AC 50/60 Hz coil

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

range
TeSys
Range of Product
TeSys D
Product or Component Type
Contactor
device short name
LC1D
contactor application
Motor control;Resistive load
utilisation category
AC-3;AC-4;AC-1;AC-3e
poles description
3P
[Ue] rated operational voltage
Power circuit <= 1000 V AC 25...400 Hz;Power circuit <= 300 V DC
[Ie] rated operational current
200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;150 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;150 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
[Uc] control circuit voltage
220 V AC 50/60 Hz
motor power kW
40 kW 220...230 V AC 50/60 Hz AC-3);75 kW 380...400 V AC 50/60 Hz AC-3);80 kW 415...440 V AC 50/60 Hz AC-3);90 kW 500 V AC 50/60 Hz AC-3);100 kW 660...690 V AC 50/60 Hz AC-3);75 kW 1000 V AC 50/60 Hz AC-3);22 kW 400 V AC 50/60 Hz AC-4);40 kW 220...230 V AC 50/60 Hz AC-3e);75 kW 380...400 V AC 50/60 Hz AC-3e);80 kW 415...440 V AC 50/60 Hz AC-3e);90 kW 500 V AC 50/60 Hz AC-3e);100 kW 660...690 V AC 50/60 Hz AC-3e);75 kW 1000 V AC 50/60 Hz AC-3e)
Maximum Horse Power Rating
40 hp 200/208 V at AC 50/60 Hz for 3 phase;50 hp 230/240 V at AC 50/60 Hz for 3 phase;100 hp 460/480 V at AC 50/60 Hz for 3 phase;125 hp 575/600 V at AC 50/60 Hz for 3 phase
compatibility code
LC1D
pole contact composition
3 NO
contact compatibility
M13
protective cover
With
[Ith] conventional free air thermal current
200 A 140 °F (60 °C) power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1;1660 A 440 V power circuit IEC 60947
rated breaking capacity
1400 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
250 A 104 °F (40 °C) - 10 min power circuit;580 A 104 °F (40 °C) - 1 min power circuit;1200 A 104 °F (40 °C) - 10 s power circuit;1400 A 104 °F (40 °C) - 1 s power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1;315 A gG <= 690 V type 1 power circuit;250 A gG <= 690 V type 2 power circuit
average impedance
0.6 mOhm - Ith 200 A 50 Hz power circuit
power dissipation per pole
24 W AC-1;13.5 W AC-3;13.5 W AC-3e
[Ui] rated insulation voltage
Power circuit 600 V CSA;Power circuit 600 V UL;Power circuit 1000 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL
overvoltage category
III
pollution degree
3
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
8 Mcycles
electrical durability
0.85 Mcycles 150 A AC-3 <= 440 V;1 Mcycles 200 A AC-1 <= 440 V;0.85 Mcycles 150 A AC-3e <= 440 V
control circuit type
AC 50/60 Hz standard
coil technology
Built-in bidirectional peak limiting diode suppressor
control circuit voltage limits
0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz;1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
inrush power in VA
280…350 VA 60 Hz 0.9 68 °F (20 °C));280…350 VA 50 Hz 0.9 68 °F (20 °C))
hold-in power consumption in VA
2…18 VA 60 Hz 0.9 68 °F (20 °C));2…18 VA 50 Hz 0.9 68 °F (20 °C))
heat dissipation
3…4.5 W 50/60 Hz
operating time
20...35 ms closing;40...75 ms opening
maximum operating rate
1200 cyc/h 140 °F (60 °C)
connections - terminals
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) solid without cable end;Power circuit connector 1 0.02…0.19 in² (10…120 mm²) flexible without cable end;Power circuit connector 2 0.02…0.08 in² (10…50 mm²) flexible without cable end;Power circuit connector 1 0.02…0.19 in² (10…120 mm²) flexible with cable end;Power circuit connector 2 0.02…0.08 in² (10…50 mm²) flexible with cable end;Power circuit connector 1 0.02…0.19 in² (10…120 mm²) solid without cable end;Power circuit connector 2 0.02…0.08 in² (10…50 mm²) solid without cable end
tightening torque
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2;Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm);Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
auxiliary contact composition
1 NO + 1 NC
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching voltage
17 V signalling circuit
minimum switching current
5 mA signalling circuit
insulation resistance
> 10 MOhm signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
Mounting Support
Rail;Plate
standards
CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508
Product Certifications
CCC;LROS (Lloyds register of shipping);GL;GOST;RINA;CSA;BV;UL;DNV;UKCA;CE
IP degree of protection
IP20 front face IEC 60529
protective treatment
THIEC 60068-2-30
climatic withstand
IACS E10 exposure to damp heat
permissible ambient air temperature around the device
-40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating
operating altitude
0...9842.52 ft (0...3000 m)
fire resistance
1562 °F (850 °C) IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor closed 15 Gn for 11 ms);Shocks contactor open 6 Gn for 11 ms)
Height
6.22 in (158 mm)
Width
4.72 in (120 mm)
Depth
5.35 in (136 mm)
Net Weight
5.51 lb(US) (2.5 kg)
Category
22359-CTR;TESYS D;OPEN;80-150A AC&DC
Discount Schedule
I12
GTIN
3389110476057
Returnability
Yes
Country of origin
CZ
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
8.27 in (21.000 cm)
Package 1 Width
7.87 in (20.000 cm)
Package 1 Length
9.25 in (23.500 cm)
Package 1 Weight
5.49 lb(US) (2.490 kg)
Unit Type of Package 2
P06
Number of Units in Package 2
27
Package 2 Height
29.53 in (75.000 cm)
Package 2 Width
23.62 in (60.000 cm)
Package 2 Length
31.50 in (80.000 cm)
Package 2 Weight
175.97 lb(US) (79.819 kg)
Warranty
18 months

Reviews

People Also Searched
LC1D150M7
Square D LC1D150M7
LC1D150M7 price
Square D LC1D150M7 price