LC2D09G7V | IEC contactor, TeSys Deca reversing, 9A, 5HP at 480VAC, 3 phase, 3P, 3NO, 120VAC 50/60Hz coil, open style | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: LC2D09G7V

Web Price:

$262.11
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

LC2D09G7V | IEC contactor, TeSys Deca reversing, 9A, 5HP at 480VAC, 3 phase, 3P, 3NO, 120VAC 50/60Hz coil, open style | Square D by Schneider Electric

Square D | LC2D09G7V
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC2D09G7V

Documents and manuals

Square D LC2D09G7V Documents

Overview

Details for LC2D09G7V

IEC contactor, TeSys Deca reversing, 9A, 5HP at 480VAC, 3 phase, 3P, 3NO, 120VAC 50/60Hz coil, open style

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A reversing inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 1HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Pressure wire connectors are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 3.54 inches wide and 3.39 inches deep. It weighs 1.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

Range
TeSys, TeSys Deca
Product name
TeSys D, TeSys Deca
Product or Component Type
Reversing contactor
Device short name
LC2D
Contactor application
Resistive load, Motor control
Utilisation category
AC-3, AC-1
Device presentation
Preassembled with reversing power busbar
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz, Power circuit <= 300 V DC
[Ie] rated operational current
9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit, 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
motor power kW
2.2 kW 220...230 V AC 50 Hz, 4 kW 380...400 V AC 50 Hz, 4 kW 415...440 V AC 50 Hz, 5.5 kW 500 V AC 50 Hz, 5.5 kW 660...690 V AC 50 Hz
motor power HP (UL / CSA)
0.5 hp 115 V at AC 60 Hz for 1 phase, 1 hp 230/240 V at AC 60 Hz for 1 phase, 2 hp 200/208 V at AC 60 Hz for 3 phase, 2 hp 230/240 V at AC 60 Hz for 3 phase, 5 hp 460/480 V at AC 60 Hz for 3 phase, 7.5 hp 575/600 V at AC 60 Hz for 3 phase
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
120 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal current
10 A 140 °F (60 °C) signalling circuit, 25 A 140 °F (60 °C) power circuit
Irms rated making capacity
250 A 440 V power circuit IEC 60947, 140 A AC signalling circuit IEC 60947-5-1, 250 A DC signalling circuit IEC 60947-5-1
rated breaking capacity
250 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
30 A 104 °F (40 °C) - 10 min power circuit, 61 A 104 °F (40 °C) - 1 min power circuit, 105 A 104 °F (40 °C) - 10 s power circuit, 210 A 104 °F (40 °C) - 1 s power circuit, 100 A - 1 s signalling circuit, 120 A - 500 ms signalling circuit, 140 A - 100 ms signalling circuit
associated fuse rating
25 A gG <= 690 V type 1 power circuit, 20 A gG <= 690 V type 2 power circuit, 10 A gG signalling circuit IEC 60947-5-1
average impedance
2.5 mOhm - Ith 25 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
electrical durability
0.6 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V
power dissipation per pole
0.2 W AC-3, 1.56 W AC-1
Front cover
With
Interlocking type
Electrical and mechanical
Mounting Support
Rail, Plate
standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1
Product Certifications
DNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA
connections - terminals
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end, Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end, Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end, Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end, Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid, Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid
tightening torque
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2, Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
operating time
12...22 ms closing, 4...19 ms opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
15 Mcycles
maximum operating rate
3600 cyc/h 140 °F (60 °C)
Coil technology
Without built-in suppressor module
control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz, 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz, 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz, 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA
70 VA 60 Hz 0.75 68 °F (20 °C)), 70 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
7.5 VA 60 Hz 0.3 68 °F (20 °C)), 7 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
2…3 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
IP degree of protection
IP20 front face IEC 60529
climatic withstand
IACS E10, IEC 60947-1 Annex Q category D
protective treatment
TH IEC 60068-2-30
Pollution degree
3
ambient air temperature for operation
-40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
operating altitude
0...9842.52 ft (0...3000 m)
fire resistance
1562 °F (850 °C) IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz, Vibrations contactor closed4 Gn, 5...300 Hz, Shocks contactor open10 Gn for 11 ms, Shocks contactor closed15 Gn for 11 ms
Height
3.03 in (77 mm)
Width
3.54 in (90 mm)
Depth
3.39 in (86 mm)
Net Weight
1.51 lb(US) (0.687 kg)
Category
22354-CTR,TESYS D,OPEN,9-38A AC
Discount Schedule
I12
GTIN
3389110408430
Returnability
Yes
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.70 in (9.4 cm)
Package 1 Width
4.49 in (11.4 cm)
Package 1 Length
4.33 in (11.0 cm)
Package 1 Weight
25.75 oz (730.0 g)
Warranty
18 months

Reviews

People Also Searched
LC2D09G7V
Square D LC2D09G7V
LC2D09G7V price
Square D LC2D09G7V price