LC2K0601B7 | Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NC, 24VAC coil | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: LC2K0601B7

Web Price:

$139.06
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

LC2K0601B7 | Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NC, 24VAC coil | Square D by Schneider Electric

Square D | LC2K0601B7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC2K0601B7

Documents and manuals

Square D LC2K0601B7 Documents

Overview

Details for LC2K0601B7

Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NC, 24VAC coil

LC2K0601B7 is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 6A AC-3 2.2kW@400V, it includes a 24V 50/60Hz AC coil, 2NC auxiliary contacts, a mechanical interlock and pre-wired reversing circuit. LC2K0601B7 is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It includes a 24V 50/60Hz AC coil and 2NC built-in auxiliary contacts. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Provides a 24V AC coil compatible 50/60Hz and 2NC built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Specifications

Range
TeSys
Product name
TeSys K
Product or Component Type
Reversing contactor
Device short name
LC2K
Device Application
Control
Contactor application
Motor control
Utilisation category
AC-4, AC-3, AC-3e
Device presentation
Preassembled with reversing power busbar
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit 690 V AC 50/60 Hz, Signalling circuit <= 690 V AC 50/60 Hz
[Ie] rated operational current
6 A<= 440 V AC AC-3 power circuit, 6 A<= 440 V AC AC-3e power circuit
motor power kW
1.5 kW 220...230 V AC 50/60 Hz, 2.2 kW 380...415 V AC 50/60 Hz, 3 kW 440 V AC 50/60 Hz, 3 kW 480 V AC 50/60 Hz, 3 kW 500...600 V AC 50/60 Hz, 3 kW 660...690 V AC 50/60 Hz
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
24 V AC 50/60 Hz
Auxiliary contact composition
1 NC
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
20 A 122 °F (50 °C) power circuit, 10 A 122 °F (50 °C) signalling circuit
Irms rated making capacity
110 A AC power circuit NF C 63-110, 110 A AC power circuit IEC 60947, 110 A AC signalling circuit IEC 60947
rated breaking capacity
110 A 415 V IEC 60947, 110 A 440 V IEC 60947, 80 A 500 V IEC 60947, 110 A 220...230 V IEC 60947, 110 A 380...400 V IEC 60947, 70 A 660...690 V IEC 60947
[Icw] rated short-time withstand current
90 A 122 °F (50 °C) - 1 s power circuit, 85 A 122 °F (50 °C) - 5 s power circuit, 80 A 122 °F (50 °C) - 10 s power circuit, 60 A 122 °F (50 °C) - 30 s power circuit, 45 A 122 °F (50 °C) - 1 min power circuit, 40 A 122 °F (50 °C) - 3 min power circuit, 80 A - 1 s signalling circuit, 90 A - 500 ms signalling circuit, 110 A - 100 ms signalling circuit, 20 A 122 °F (50 °C) - >= 15 min power circuit
associated fuse rating
25 A gG <= 440 V power circuit, 25 A aM power circuit, 10 A gG signalling circuit IEC 60947, 10 A gG signalling circuit VDE 0660
average impedance
3 mOhm - Ith 20 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
electrical durability
1.3 Mcycles 6 A AC-3 <= 440 V, 1.3 Mcycles 6 A AC-3e <= 440 V
Interlocking type
Mechanical
Mounting Support
Plate, Rail
standards
VDE 0660, NF C 63-110, IEC 60947, BS 5424
Product Certifications
UL, CSA, UKCA
connections - terminals
screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid, screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end, screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end, screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid, screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end, screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
tightening torque
7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2, 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm, 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
operating time
10...20 ms coil energisation and NO closing, 10...20 ms coil de-energisation and NO opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
5 Mcycles
maximum operating rate
3600 cyc/h
control circuit voltage limits
Operational 0.8...1.15 Uc 122 °F (50 °C)), Drop-out 0.2...0.75 Uc 122 °F (50 °C))
inrush power in VA
30 VA 68 °F (20 °C))
hold-in power consumption in VA
4.5 VA 68 °F (20 °C))
heat dissipation
1.3 W
auxiliary contacts type
Instantaneous 1 NC
Signalling circuit frequency
<= 400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non overlap distance
0.02 in (0.5 mm)
insulation resistance
> 10 MOhm signalling circuit
IP degree of protection
IP20 VDE 0106
protective treatment
TC IEC 60068, TC DIN 50016
Ambient Air Temperature for Operation
-13…122 °F (-25…50 °C)
Ambient Air Temperature for Storage
-58…176 °F (-50…80 °C)
operating altitude
6561.68 ft (2000 m) without derating
flame retardance
V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
mechanical robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Height
2.28 in (58 mm)
Width
3.54 in (90 mm)
Depth
2.24 in (57 mm)
Net Weight
0.86 lb(US) (0.39 kg)
Category
22327-CTR,K-LINE,AC,OPEN,REV
Discount Schedule
I12
GTIN
3389110428520
Returnability
Yes
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.56 in (6.5 cm)
Package 1 Width
3.54 in (9 cm)
Package 1 Length
2.36 in (6 cm)
Package 1 Weight
12.70 oz (360 g)
Unit Type of Package 2
S02
Number of Units in Package 2
25
Package 2 Height
5.91 in (15 cm)
Package 2 Width
11.81 in (30 cm)
Package 2 Length
15.75 in (40 cm)
Package 2 Weight
20.85 lb(US) (9.456 kg)
Unit Type of Package 3
P06
Number of Units in Package 3
200
Package 3 Height
17.72 in (45 cm)
Package 3 Width
31.50 in (80 cm)
Package 3 Length
23.62 in (60 cm)
Package 3 Weight
185.50 lb(US) (84.14 kg)
Warranty
18 months