LC2D40AF7 | TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V AC coil | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: LC2D40AF7

Web Price:

$595.13
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

LC2D40AF7 | TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V AC coil | Square D by Schneider Electric

Square D | LC2D40AF7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC2D40AF7

Documents and manuals

Square D LC2D40AF7 Documents

Overview

Details for LC2D40AF7

TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V AC coil

LC2D40AF7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 40A AC-3 18.5kW@400V, it includes a 110V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D40AF7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 18.5kW@400V. It includes a 110V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 110V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 40A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.

Specifications

Range
TeSys, TeSys Deca
Product name
TeSys D, TeSys Deca
Product or Component Type
Reversing contactor
Device short name
LC2D
Contactor application
Resistive load, Motor control
Utilisation category
AC-3, AC-1
Device presentation
Preassembled with reversing power busbar
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz, Power circuit <= 300 V DC
[Ie] rated operational current
40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit, 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
motor power kW
18.5 kW 380...400 V AC 50 Hz, 11 kW 220...230 V AC 50 Hz, 22 kW 415...440 V AC 50 Hz, 22 kW 500 V AC 50 Hz, 30 kW 660...690 V AC 50 Hz
motor power HP (UL / CSA)
5 hp 230/240 V at AC 60 Hz for 1 phase, 10 hp 230/240 V at AC 60 Hz for 3 phase, 30 hp 575/600 V at AC 60 Hz for 3 phase, 10 hp 200/208 V at AC 60 Hz for 3 phase, 3 hp 115 V at AC 60 Hz for 1 phase, 30 hp 460/480 V at AC 60 Hz for 3 phase
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
110 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal current
10 A 140 °F (60 °C) signalling circuit, 60 A 140 °F (60 °C) power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1, 250 A DC signalling circuit IEC 60947-5-1, 800 A 440 V power circuit IEC 60947
rated breaking capacity
800 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
72 A 104 °F (40 °C) - 10 min power circuit, 165 A 104 °F (40 °C) - 1 min power circuit, 320 A 104 °F (40 °C) - 10 s power circuit, 720 A 104 °F (40 °C) - 1 s power circuit, 100 A - 1 s signalling circuit, 120 A - 500 ms signalling circuit, 140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1, 80 A gG <= 690 V type 1 power circuit, 80 A gG <= 690 V type 2 power circuit
average impedance
1.5 mOhm - Ith 60 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
electrical durability
1.5 Mcycles 40 A AC-3 <= 440 V, 1.4 Mcycles 60 A AC-1 <= 440 V
power dissipation per pole
2.4 W AC-3, 5.4 W AC-1
Front cover
With
Interlocking type
Mechanical
Mounting Support
Plate, Rail
standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1
Product Certifications
UL, CSA, RINA, GOST, CCC, DNV, LROS (Lloyds register of shipping), GL, BV, UKCA
connections - terminals
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid, Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible without cable end, Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible without cable end, Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible with cable end, Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible with cable end, Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)solid, Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)solid
tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm), Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm), Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2, Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
operating time
4...19 ms opening, 12...26 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
6 Mcycles
maximum operating rate
3600 cyc/h 140 °F (60 °C)
Coil technology
Without built-in suppressor module
control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz, 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz, 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz, 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA
140 VA 60 Hz 0.75 68 °F (20 °C)), 160 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
13 VA 60 Hz 0.3 68 °F (20 °C)), 15 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
4…5 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
IP degree of protection
IP20 front face IEC 60529
climatic withstand
IACS E10, IEC 60947-1 Annex Q category D
protective treatment
TH IEC 60068-2-30
Pollution degree
3
ambient air temperature for operation
-40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
operating altitude
0...9842.52 ft (0...3000 m)
fire resistance
1562 °F (850 °C) IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz, Vibrations contactor closed4 Gn, 5...300 Hz, Shocks contactor open10 Gn for 11 ms, Shocks contactor closed15 Gn for 11 ms
Height
4.80 in (122 mm)
Width
4.69 in (119 mm)
Depth
4.72 in (120 mm)
Net Weight
4.12 lb(US) (1.87 kg)
Category
22357-CTR,TESYS D,OPEN,40-65A AC
Discount Schedule
I12
GTIN
3389119409490
Returnability
Yes
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.51 in (14 cm)
Package 1 Width
6.38 in (16.2 cm)
Package 1 Length
7.80 in (19.8 cm)
Package 1 Weight
4.57 lb(US) (2.073 kg)
Unit Type of Package 2
S03
Number of Units in Package 2
4
Package 2 Height
11.81 in (30 cm)
Package 2 Width
11.81 in (30 cm)
Package 2 Length
15.75 in (40 cm)
Package 2 Weight
19.46 lb(US) (8.828 kg)
Unit Type of Package 3
P06
Number of Units in Package 3
32
Package 3 Height
29.53 in (75 cm)
Package 3 Width
23.62 in (60 cm)
Package 3 Length
31.50 in (80 cm)
Package 3 Weight
177.56 lb(US) (80.54 kg)
Warranty
18 months