LC2D32E7 | TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V AC coil | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: LC2D32E7

Web Price:

$469.64
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

LC2D32E7 | TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V AC coil | Square D by Schneider Electric

Square D | LC2D32E7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC2D32E7

Documents and manuals

Square D LC2D32E7 Documents

Overview

Details for LC2D32E7

TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V AC coil

LC2D32E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 32A AC-3 15kW@400V, it includes a 48V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D32E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 15kW@400V. It includes a 48V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 48V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 32A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.

Specifications

Range
TeSys, TeSys Deca
Product name
TeSys D, TeSys Deca
Product or Component Type
Reversing contactor
Device short name
LC2D
Contactor application
Resistive load, Motor control
Utilisation category
AC-1, AC-3
Device presentation
Preassembled with reversing power busbar
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz, Power circuit <= 300 V DC
[Ie] rated operational current
32 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit, 50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
motor power kW
7.5 kW 220...230 V AC 50 Hz, 15 kW 380...400 V AC 50 Hz, 15 kW 415...440 V AC 50 Hz, 18.5 kW 500 V AC 50 Hz, 18.5 kW 660...690 V AC 50 Hz
motor power HP (UL / CSA)
2 hp 115 V at AC 60 Hz for 1 phase, 5 hp 230/240 V at AC 60 Hz for 1 phase, 7.5 hp 200/208 V at AC 60 Hz for 3 phase, 10 hp 230/240 V at AC 60 Hz for 3 phase, 20 hp 460/480 V at AC 60 Hz for 3 phase, 30 hp 575/600 V at AC 60 Hz for 3 phase
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
48 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal current
10 A 140 °F (60 °C) signalling circuit, 50 A 140 °F (60 °C) power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1, 250 A DC signalling circuit IEC 60947-5-1, 550 A 440 V power circuit IEC 60947
rated breaking capacity
550 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
60 A 104 °F (40 °C) - 10 min power circuit, 138 A 104 °F (40 °C) - 1 min power circuit, 260 A 104 °F (40 °C) - 10 s power circuit, 430 A 104 °F (40 °C) - 1 s power circuit, 100 A - 1 s signalling circuit, 120 A - 500 ms signalling circuit, 140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1, 63 A gG <= 690 V type 1 power circuit, 63 A gG <= 690 V type 2 power circuit
average impedance
2 mOhm - Ith 50 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
electrical durability
1.65 Mcycles 32 A AC-3 <= 440 V, 1.4 Mcycles 50 A AC-1 <= 440 V
power dissipation per pole
2 W AC-3, 5 W AC-1
Front cover
With
Interlocking type
Mechanical
Mounting Support
Plate, Rail
standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1
Product Certifications
UL, CSA, RINA, GOST, CCC, DNV, LROS (Lloyds register of shipping), GL, BV, UKCA
connections - terminals
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid, Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²)flexible without cable end, Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)flexible without cable end, Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²)flexible with cable end, Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)flexible with cable end, Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²)solid, Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)solid
tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm, Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2, Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
operating time
12...22 ms closing, 4...19 ms opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
15 Mcycles
maximum operating rate
3600 cyc/h 140 °F (60 °C)
Coil technology
Without built-in suppressor module
control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz, 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz, 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz, 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA
70 VA 60 Hz 0.75 68 °F (20 °C)), 70 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
7.5 VA 60 Hz 0.3 68 °F (20 °C)), 7 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
2…3 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
IP degree of protection
IP20 front face IEC 60529
climatic withstand
IACS E10, IEC 60947-1 Annex Q category D
protective treatment
TH IEC 60068-2-30
Pollution degree
3
ambient air temperature for operation
-40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
operating altitude
0...9842.52 ft (0...3000 m)
fire resistance
1562 °F (850 °C) IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz, Vibrations contactor closed4 Gn, 5...300 Hz, Shocks contactor closed15 Gn for 11 ms, Shocks contactor open8 Gn for 11 ms
Height
3.35 in (85 mm)
Width
3.54 in (90 mm)
Depth
3.62 in (92 mm)
Net Weight
1.76 lb(US) (0.797 kg)
Category
22354-CTR,TESYS D,OPEN,9-38A AC
Discount Schedule
I12
GTIN
3389110391473
Returnability
No
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.53 in (11.5 cm)
Package 1 Width
4.53 in (11.5 cm)
Package 1 Length
5.51 in (14 cm)
Package 1 Weight
33.05 oz (937 g)
Unit Type of Package 2
S02
Number of Units in Package 2
5
Package 2 Height
5.91 in (15 cm)
Package 2 Width
11.81 in (30 cm)
Package 2 Length
15.75 in (40 cm)
Package 2 Weight
11.08 lb(US) (5.028 kg)
Warranty
18 months

Reviews

People Also Searched
LC2D32E7
Square D LC2D32E7
LC2D32E7 price
Square D LC2D32E7 price