Get Special Pricing!
LC1DT60AG7 | IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style | Square D by Schneider Electric
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1DT60AG7
Overview
Details for LC1DT60AG7
IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.Specifications
- range
- TeSys;TeSys Deca
- Range of Product
- TeSys D;TeSys Deca
- Product or Component Type
- Contactor
- device short name
- LC1D
- contactor application
- Resistive load
- utilisation category
- AC-1
- poles description
- 4P
- [Ue] rated operational voltage
- Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC
- [Ie] rated operational current
- 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- [Uc] control circuit voltage
- 120 V AC 60 Hz
- compatibility code
- LC1D
- pole contact composition
- 4 NO
- contact compatibility
- M6
- protective cover
- With
- [Ith] conventional free air thermal current
- 10 A 140 °F (60 °C) signalling circuit;60 A 140 °F (60 °C) power circuit
- Irms rated making capacity
- 140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1;800 A 440 V power circuit IEC 60947
- rated breaking capacity
- 800 A 440 V power circuit IEC 60947
- [Icw] rated short-time withstand current
- 320 A 104 °F (40 °C) - 10 s power circuit;720 A 104 °F (40 °C) - 1 s power circuit;72 A 104 °F (40 °C) - 10 min power circuit;165 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit
- associated fuse rating
- 10 A gG signalling circuit IEC 60947-5-1;80 A gG <= 690 V type 1 power circuit;80 A gG <= 690 V type 2 power circuit
- average impedance
- 1.6 mOhm - Ith 60 A 50 Hz power circuit
- power dissipation per pole
- 5.8 W AC-1
- [Ui] rated insulation voltage
- Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL;Power circuit 690 V IEC 60947-4-1
- overvoltage category
- III
- pollution degree
- 3
- [Uimp] rated impulse withstand voltage
- 6 kV IEC 60947
- safety reliability level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- mechanical durability
- 6 Mcycles
- electrical durability
- 1.4 Mcycles 60 A AC-1 <= 440 V
- control circuit type
- AC 60 Hz
- coil technology
- Without built-in suppressor module
- control circuit voltage limits
- 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 60 Hz;0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz;1...1.1 Uc 140…158 °F (60…70 °C) operational AC 60 Hz
- inrush power in VA
- 140 VA 60 Hz 0.75 68 °F (20 °C))
- hold-in power consumption in VA
- 13 VA 60 Hz 0.3 68 °F (20 °C))
- heat dissipation
- 4…5 W 60 Hz
- operating time
- 4...19 ms opening;12...26 ms closing
- maximum operating rate
- 3600 cyc/h 140 °F (60 °C)
- connections - terminals
- Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²) flexible without cable end;Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²) flexible without cable end;Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²) flexible with cable end;Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²) flexible with cable end;Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²) solid without cable end;Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²) solid without cable end
- tightening torque
- Control circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors flat Ø 6 mm;Control circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors Philips No 2;Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm);Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm);Control circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors pozidriv No 2;Power circuit 22.13 lbf.in (2.5 N.m) EverLink BTR screw connectors pozidriv No 2
- auxiliary contact composition
- 1 NO + 1 NC
- auxiliary contacts type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1
- signalling circuit frequency
- 25...400 Hz
- minimum switching voltage
- 17 V signalling circuit
- minimum switching current
- 5 mA signalling circuit
- insulation resistance
- > 10 MOhm signalling circuit
- non-overlap time
- 1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
- Mounting Support
- Rail;Plate
- standards
- CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1
- Product Certifications
- RINA;CSA;GOST;LROS (Lloyds register of shipping);DNV;CCC;UL;GL;BV
- IP degree of protection
- IP20 front face IEC 60529
- protective treatment
- THIEC 60068-2-30
- climatic withstand
- IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat
- permissible ambient air temperature around the device
- -40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating
- operating altitude
- 0...9842.52 ft (0...3000 m)
- fire resistance
- 1562 °F (850 °C) IEC 60695-2-1
- flame retardance
- V1 conforming to UL 94
- mechanical robustness
- Vibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor closed 15 Gn for 11 ms);Shocks contactor open 10 Gn for 11 ms)
- Height
- 4.80 in (122 mm)
- Width
- 2.76 in (70 mm)
- Depth
- 4.72 in (120 mm)
- Net Weight
- 2.40 lb(US) (1.09 kg)
- Category
- 22357-CTR;TESYS D;OPEN;40-65A AC
- Discount Schedule
- I12
- GTIN
- 3389119409285
- Returnability
- Yes
- Country of origin
- FR
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 3.11 in (7.9 cm)
- Package 1 Width
- 5.43 in (13.8 cm)
- Package 1 Length
- 6.02 in (15.3 cm)
- Package 1 Weight
- 2.42 lb(US) (1.097 kg)
- Unit Type of Package 2
- S02
- Number of Units in Package 2
- 7
- Package 2 Height
- 5.91 in (15 cm)
- Package 2 Width
- 11.81 in (30 cm)
- Package 2 Length
- 15.75 in (40 cm)
- Package 2 Weight
- 17.93 lb(US) (8.134 kg)
- Unit Type of Package 3
- P06
- Number of Units in Package 3
- 112
- Package 3 Height
- 30.31 in (77 cm)
- Package 3 Width
- 31.50 in (80 cm)
- Package 3 Length
- 23.62 in (60 cm)
- Package 3 Weight
- 305.66 lb(US) (138.644 kg)
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
![Square D 171CBU98090 UNITY M1E SERIAL 232/485 | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-171cbu98090_951adf2b-795f-4ac5-ac3d-bb93d6599bea_large.png?v=1720094843)
171CBU98090 | UNITY M1E SERIAL 232/485 | Square D by Schneider Electric
Brand: Square D
SKU: 171CBU98090![Square D 2601AG2 DRUM SWITCH 600VAC 2HP A +OPTION | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-2601ag2_9e868e65-1227-4ca2-9f22-aaaeeb6be3a5_large.png?v=1720094843)
2601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D by Schneider Electric
Brand: Square D
SKU: 2601AG2![Square D 8911DPSO32V09 Definite Purpose Starter, 30A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-8911dpso32v09_large.png?v=1720019268)
8911DPSO32V09 | Definite Purpose Starter, 30A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO32V09![Square D 8911DPSO42V09 Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-8911dpso42v09_large.png?v=1720019289)
8911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO42V09![Square D 9001BWAEQ3439G3 PENDANT STATION 600VAC 5A T-BW SPECIAL | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/SQD-9001BWAEQ3439G3_300x_97cfbbb7-eac5-4e37-90e3-59db092b82f0_large.jpg?v=1715270770)
9001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G3People Also Searched
LC1DT60AG7
Square D LC1DT60AG7
LC1DT60AG7 price
Square D LC1DT60AG7 price