Square D | LC1D95U7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1D95U7

Documents and manuals

Square D LC1D95U7 Documents

Overview

Details for LC1D95U7

IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 240VAC 50/60Hz coil, open style

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

range
TeSys
Range of Product
TeSys D
Product or Component Type
Contactor
device short name
LC1D
contactor application
Motor control;Resistive load
utilisation category
AC-1;AC-4;AC-3;AC-3e
poles description
3P
[Ue] rated operational voltage
Power circuit 1000 V AC 25...400 Hz
[Ie] rated operational current
95 A 140 °F (60 °C)) <= 440 V AC-3 power circuit;125 A 140 °F (60 °C)) <= 690 V AC-1 power circuit;95 A 140 °F (60 °C)) <= 440 V AC-3e power circuit
[Uc] control circuit voltage
240 V AC 50/60 Hz
motor power kW
25 kW 220...230 V AC 50 Hz AC-3);45 kW 380...400 V AC 50 Hz AC-3);45 kW 415...440 V AC 50 Hz AC-3);55 kW 500 V AC 50 Hz AC-3);45 kW 660...690 V AC 50 Hz AC-3);45 kW 1000 V AC 50 Hz AC-3)
Maximum Horse Power Rating
7.5 hp 120 V at AC 60 Hz for 1 phase;15 hp 230/240 V at AC 60 Hz for 1 phase;30 hp 200/208 V at AC 60 Hz for 3 phase;30 hp 230/240 V at AC 60 Hz for 3 phase;60 hp 460/480 V at AC 60 Hz for 3 phase;60 hp 575/600 V at AC 60 Hz for 3 phase
compatibility code
LC1D
pole contact composition
3 NO
contact compatibility
M11
protective cover
With
[Ith] conventional free air thermal current
10 A 140 °F (60 °C) signalling circuit;125 A 140 °F (60 °C) power circuit
Irms rated making capacity
1100 A 440 V AC power circuit IEC 60947;140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1
rated breaking capacity
1100 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
1100 A 104 °F (40 °C) - 1 s power circuit;800 A 104 °F (40 °C) - 10 s power circuit;400 A 104 °F (40 °C) - 1 min power circuit;135 A 104 °F (40 °C) - 10 min power circuit;140 A - 100 ms signalling circuit;120 A - 500 ms signalling circuit;100 A - 1 s signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1;200 A gG <= 690 V type 1 power circuit;160 A gG <= 690 V type 2 power circuit
average impedance
0.8 mOhm - Ith 125 A 50 Hz power circuit
power dissipation per pole
12.5 W AC-1;7.2 W AC-3;7.2 W AC-3e
[Ui] rated insulation voltage
Power circuit 1000 V IEC 60947-4-1;Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL
overvoltage category
III
pollution degree
3
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
safety reliability level
B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1;B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
4 Mcycles
electrical durability
1.2 Mcycles 95 A AC-3;1.3 Mcycles 125 A AC-1;1.2 Mcycles 95 A AC-3e
control circuit type
AC 50/60 Hz
coil technology
Without built-in suppressor module
control circuit voltage limits
0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz;0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz;0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
inrush power in VA
245 VA 60 Hz 0.75 68 °F (20 °C));245 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
26 VA 60 Hz 0.3 68 °F (20 °C));26 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
6…10 W 50/60 Hz
operating time
20...35 ms closing;6...20 ms opening
maximum operating rate
3600 cyc/h 140 °F (60 °C)
connections - terminals
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit connector 1 0.01…0.08 in² (4…50 mm²) flexible without cable end;Power circuit connector 2 0.01…0.04 in² (4…25 mm²) flexible without cable end;Power circuit connector 1 0.01…0.08 in² (4…50 mm²) flexible with cable end;Power circuit connector 2 0.01…0.02 in² (4…16 mm²) flexible with cable end;Power circuit connector 1 0.01…0.08 in² (4…50 mm²) solid without cable end;Power circuit connector 2 0.01…0.04 in² (4…25 mm²) solid without cable end
tightening torque
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2;Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm;Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm);Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
auxiliary contact composition
1 NO + 1 NC
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching voltage
17 V signalling circuit
minimum switching current
5 mA signalling circuit
insulation resistance
> 10 MOhm signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
Mounting Support
Rail;Plate
standards
EN/IEC 60947-1;EN/IEC 60947-4-1;EN/IEC 60947-5-1;UL 60947-4-1;UL 60947-5-1;CSA C22.2 No 60947-4-1;CSA C22.2 No 60947-5-1;GB/T 14048.4
Product Certifications
IECEE CB Scheme;UL;CSA;CCC;EAC;LROS (Lloyds register of shipping);RINA;BV;DNV-GL
IP degree of protection
IP20 front face IEC 60529
protective treatment
THIEC 60068-2-30
climatic withstand
IACS E10 exposure to damp heat
permissible ambient air temperature around the device
-40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating
operating altitude
0...9842.52 ft (0...3000 m)
fire resistance
1562 °F (850 °C) IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open 2 Gn;5...300 Hz);Shocks contactor open 8 Gn for 11 ms);Vibrations contactor closed 3 Gn;5...300 Hz);Shocks contactor closed 10 Gn for 11 ms)
Height
5.00 in (127 mm)
Width
3.35 in (85 mm)
Depth
5.12 in (130 mm)
Net Weight
3.55 lb(US) (1.61 kg)
Category
22359-CTR;TESYS D;OPEN;80-150A AC&DC
Discount Schedule
I12
GTIN
3389110452051
Returnability
Yes
Country of origin
CZ
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.20 in (13.2 cm)
Package 1 Width
5.20 in (13.2 cm)
Package 1 Length
3.74 in (9.5 cm)
Package 1 Weight
3.45 lb(US) (1.563 kg)
Unit Type of Package 2
S02
Number of Units in Package 2
5
Package 2 Height
5.91 in (15.0 cm)
Package 2 Width
11.81 in (30.0 cm)
Package 2 Length
15.75 in (40.0 cm)
Package 2 Weight
17.86 lb(US) (8.1 kg)