LC1D65AM7 | IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open | Square D by Schneider Electric
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!

Web Price:

$344.84
Availability: This product is currently available to purchase

Contact us for price breaks on large quantities!

Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs. Shipping and Returns Terms
Ship to Estimates
Are you from Chicago?
Yes / No
This item ships to
Change
Cancel


*shipping cost are estimated until you complete your order

Speak With a Technical Expert

Image for Technical Expert

Documents: LC1D65AM7

LC1D65AM7 | IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open | Square D by Schneider Electric

Brand: Square DSKU: LC1D65AM7
Square D | LC1D65AM7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1D65AM7

Overview Details for LC1D65AM7

IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

range
TeSys;TeSys Deca
Range of Product
TeSys D;TeSys Deca
Product or Component Type
Contactor
device short name
LC1D
contactor application
Motor control;Resistive load
utilisation category
AC-4;AC-1;AC-3;AC-3e
poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC
[Ie] rated operational current
80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;65 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;65 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
[Uc] control circuit voltage
220 V AC 50/60 Hz
motor power kW
11 kW 400 V AC 50/60 Hz AC-4);18.5 kW 220...230 V AC 50/60 Hz AC-3);30 kW 380...400 V AC 50/60 Hz AC-3);37 kW 500 V AC 50/60 Hz AC-3);37 kW 660...690 V AC 50/60 Hz AC-3);18.5 kW 220...230 V AC 50/60 Hz AC-3e);30 kW 380...400 V AC 50/60 Hz AC-3e);37 kW 500 V AC 50/60 Hz AC-3e);37 kW 660...690 V AC 50/60 Hz AC-3e)
Maximum Horse Power Rating
40 hp 460/480 V at AC 50/60 Hz for 3 phase;5 hp 115 V at AC 50/60 Hz for 1 phase;10 hp 230/240 V at AC 50/60 Hz for 1 phase;20 hp 200/208 V at AC 50/60 Hz for 3 phase;20 hp 230/240 V at AC 50/60 Hz for 3 phase;50 hp 575/600 V at AC 50/60 Hz for 3 phase
compatibility code
LC1D
pole contact composition
3 NO
contact compatibility
M2
protective cover
With
[Ith] conventional free air thermal current
10 A 140 °F (60 °C) signalling circuit;80 A 140 °F (60 °C) power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1;1000 A 440 V power circuit IEC 60947
rated breaking capacity
1000 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
520 A 104 °F (40 °C) - 10 s power circuit;900 A 104 °F (40 °C) - 1 s power circuit;110 A 104 °F (40 °C) - 10 min power circuit;260 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1;125 A gG <= 690 V type 1 power circuit;125 A gG <= 690 V type 2 power circuit
average impedance
1.5 mOhm - Ith 80 A 50 Hz power circuit
power dissipation per pole
9.6 W AC-1;6.3 W AC-3;6.3 W AC-3e
[Ui] rated insulation voltage
Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL;Power circuit 690 V IEC 60947-4-1
overvoltage category
III
pollution degree
3
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
6 Mcycles
electrical durability
1.4 Mcycles 80 A AC-1 <= 440 V;1.45 Mcycles 65 A AC-3 <= 440 V;1.45 Mcycles 65 A AC-3e <= 440 V
control circuit type
AC 50/60 Hz standard
coil technology
Without built-in suppressor module
control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz;0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz;1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA
140 VA 60 Hz 0.75 68 °F (20 °C));160 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
13 VA 60 Hz 0.3 68 °F (20 °C));15 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
4…5 W 50/60 Hz
operating time
4...19 ms opening;12...26 ms closing
maximum operating rate
3600 cyc/h 140 °F (60 °C)
connections - terminals
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²) flexible without cable end;Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²) flexible without cable end;Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²) flexible with cable end;Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²) flexible with cable end;Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²) solid without cable end;Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²) solid without cable end
tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors flat Ø 6 mm;Control circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors Philips No 2;Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm);Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm);Control circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors pozidriv No 2;Power circuit 22.13 lbf.in (2.5 N.m) EverLink BTR screw connectors pozidriv No 2
auxiliary contact composition
1 NO + 1 NC
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching voltage
17 V signalling circuit
minimum switching current
5 mA signalling circuit
insulation resistance
> 10 MOhm signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
Mounting Support
Rail;Plate
standards
CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1
Product Certifications
UL;CCC;GOST;CSA
IP degree of protection
IP20 front face IEC 60529
protective treatment
THIEC 60068-2-30
climatic withstand
IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat
permissible ambient air temperature around the device
-40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating
operating altitude
0...9842.52 ft (0...3000 m)
fire resistance
1562 °F (850 °C) IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor closed 15 Gn for 11 ms);Shocks contactor open 10 Gn for 11 ms)
Height
4.80 in (122 mm)
Width
2.17 in (55 mm)
Depth
4.72 in (120 mm)
Net Weight
1.90 lb(US) (0.86 kg)
Category
22357-CTR;TESYS D;OPEN;40-65A AC
Discount Schedule
I12
GTIN
3389119409018
Returnability
Yes
Country of origin
ID
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.48 in (6.300 cm)
Package 1 Width
5.31 in (13.500 cm)
Package 1 Length
6.02 in (15.300 cm)
Package 1 Weight
32.56 oz (923.000 g)
Unit Type of Package 2
S02
Number of Units in Package 2
10
Package 2 Height
5.91 in (15.000 cm)
Package 2 Width
11.81 in (30.000 cm)
Package 2 Length
15.75 in (40.000 cm)
Package 2 Weight
21.71 lb(US) (9.849 kg)
Unit Type of Package 3
P06
Number of Units in Package 3
160
Package 3 Height
29.53 in (75.000 cm)
Package 3 Width
23.62 in (60.000 cm)
Package 3 Length
31.50 in (80.000 cm)
Package 3 Weight
364.66 lb(US) (165.408 kg)
Warranty
18 months