Details for LC1D40M7
IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.Specifications
- Range
- TeSys
- Range of Product
- TeSys D, TeSys Deca
- Product or Component Type
- Contactor
- Device short name
- LC1D
- Contactor application
- Motor control, Resistive load
- Utilisation category
- AC-1, AC-4, AC-2, AC-3, AC-3e
- Poles description
- 3P
- [Ue] rated operational voltage
- Power circuit <= 690 V AC 25...400 Hz
- [Ie] rated operational current
- 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit, 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit, 40 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
- [Uc] control circuit voltage
- 220 V AC 50/60 Hz
- motor power kW
- 18.5 kW 380...400 V AC 50 Hz AC-3), 22 kW 500 V AC 50 Hz AC-3), 30 kW 660...690 V AC 50 Hz AC-3), 22 kW 1000 V AC 50 Hz AC-3), 22 kW 415 V AC 50 Hz AC-3), 22 kW 440 V AC 50 Hz AC-3), 11 kW 220...230 V AC 50 Hz AC-3), 9 kW 400 V AC 50 Hz AC-4), 18.5 kW 380...400 V AC 50 Hz AC-3e), 22 kW 500 V AC 50 Hz AC-3e), 30 kW 660...690 V AC 50 Hz AC-3e), 22 kW 1000 V AC 50 Hz AC-3e), 22 kW 415 V AC 50 Hz AC-3e), 22 kW 440 V AC 50 Hz AC-3e), 11 kW 220...230 V AC 50 Hz AC-3e)
- Maximum Horse Power Rating
- 3 hp 115 V at AC 60 Hz for 1 phase, 5 hp 230/240 V at AC 60 Hz for 1 phase, 10 hp 200/208 V at AC 60 Hz for 3 phase, 10 hp 230/240 V at AC 60 Hz for 3 phase, 30 hp 460/480 V at AC 60 Hz for 3 phase, 30 hp 575/600 V at AC 60 Hz for 3 phase
- Compatibility code
- LC1D
- Pole contact composition
- 3 NO
- Protective cover
- With
- [Ith] conventional free air thermal current
- 10 A 140 °F (60 °C) control circuit, 60 A 140 °F (60 °C) power circuit
- Irms rated making capacity
- 800 A 440 V power circuit IEC 60947, 140 A AC control circuit IEC 60947-5-1
- rated breaking capacity
- 800 A 440 V power circuit IEC 60947
- associated fuse rating
- 10 A gG control circuit IEC 60947-5-1, 80 A gG <= 690 V type 1 power circuit, 80 A gG <= 690 V type 2 power circuit
- power dissipation per pole
- 5.4 W AC-1, 2.4 W AC-3, 2.4 W AC-3e
- [Ui] rated insulation voltage
- Control circuit 600 V CSA, Control circuit 600 V UL, Power circuit 600 V CSA, Power circuit 600 V UL, Control circuit 690 V IEC 60947-1, Power circuit 690 V IEC 60947-1
- Overvoltage category
- III
- [Uimp] rated impulse withstand voltage
- 8 kV IEC 60947
- safety reliability level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Mechanical durability
- 6000000 cycles
- control circuit type
- AC 50/60 Hz
- Coil technology
- Without built-in bidirectional peak limiting diode suppressor
- control circuit voltage limits
- 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz, 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz, 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz, 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- inrush power in VA
- 140 VA 0.75 68 °F (20 °C)), 160 VA 0.75 68 °F (20 °C))
- hold-in power consumption in VA
- 13 VA 60 Hz 0.3 68 °F (20 °C)), 15 VA 50 Hz 0.3 68 °F (20 °C))
- heat dissipation
- 4…5 W 50/60 Hz control circuit
- operating time
- 4...19 ms opening, 12...26 ms closing
- maximum operating rate
- 3600 cyc/h 140 °F (60 °C)
- connections - terminals
- Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) rigid, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) rigid, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end, Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) flexible with cable end, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end, Power circuit screw terminals 1 0.00…0.04 in² (2.5…25 mm²) rigid, Power circuit screw terminals 2 0.00…0.02 in² (2.5…16 mm²) rigid, Power circuit screw terminals 1 0.00…0.04 in² (2.5…25 mm²) flexible without cable end, Power circuit screw terminals 2 0.00…0.02 in² (2.5…16 mm²) flexible without cable end, Power circuit screw terminals 1 0.00…0.04 in² (2.5…25 mm²) flexible with cable end, Power circuit screw terminals 2 0.00…0.02 in² (2.5…10 mm²) flexible with cable end
- tightening torque
- Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2, Power circuit 44.25 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm, Control circuit 15.05 lbf.in (1.7 N.m) lugs pozidriv No 2
- Auxiliary contact composition
- 1 NO + 1 NC
- auxiliary contacts type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
- Terminals description ISO n°1
- (21-22)NC, (13-14)NO, (A1-A2)CO
- minimum switching voltage
- 17 V control circuit
- minimum switching current
- 5 mA control circuit
- insulation resistance
- > 10 MOhm control circuit
- non-overlap time
- 1.5 ms on de-energisation between NC and NO contacts, 1.5 ms on energisation between NC and NO contacts
- Mounting Support
- Plate, Rail
- standards
- EN 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14, EN 60947-5-1, IEC 60947-4-1, UL 508
- Product Certifications
- LROS (Lloyds register of shipping), DNV, GL, BV, CCC, RINA, CSA, UL, GOST, UKCA
- IP degree of protection
- IP2x IEC 60529, IP2x VDE 0106
- climatic withstand
- IACS E10 exposure to damp heat
- operating altitude
- 0...9842.52 ft (0...3000 m)
- fire resistance
- 1562 °F (850 °C) IEC 60695-2-1
- flame retardance
- V1 conforming to UL 94
- mechanical robustness
- Shocks contactor opened 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms), Vibrations contactor opened 2 Gn, 5...300 Hz), Vibrations contactor closed 4 Gn, 5...300 Hz)
- Height
- 5.00 in (127 mm)
- Width
- 2.95 in (75 mm)
- Depth
- 4.69 in (119 mm)
- Net Weight
- 3.09 lb(US) (1.4 kg)
- Category
- 22357-CTR,TESYS D,OPEN,40-65A AC
- Discount Schedule
- I12
- GTIN
- 3389110417333
- Returnability
- Yes
- Country of origin
- CZ
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 3.74 in (9.5 cm)
- Package 1 Width
- 5.20 in (13.2 cm)
- Package 1 Length
- 5.51 in (14.0 cm)
- Package 1 Weight
- 3.20 lb(US) (1.45 kg)
- Unit Type of Package 2
- S02
- Number of Units in Package 2
- 5
- Package 2 Height
- 5.91 in (15.0 cm)
- Package 2 Width
- 11.81 in (30.0 cm)
- Package 2 Length
- 15.75 in (40.0 cm)
- Package 2 Weight
- 16.66 lb(US) (7.555 kg)
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
![Square D 171CBU98090 UNITY M1E SERIAL 232/485 | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-171cbu98090_951adf2b-795f-4ac5-ac3d-bb93d6599bea_large.png?v=1720094843)
171CBU98090 | UNITY M1E SERIAL 232/485 | Square D by Schneider Electric
Brand: Square D
SKU: 171CBU98090![Square D 2601AG2 DRUM SWITCH 600VAC 2HP A +OPTION | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-2601ag2_9e868e65-1227-4ca2-9f22-aaaeeb6be3a5_large.png?v=1720094843)
2601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D by Schneider Electric
Brand: Square D
SKU: 2601AG2![Square D 8911DPSO32V09 Definite Purpose Starter, 30A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-8911dpso32v09_large.png?v=1720019268)
8911DPSO32V09 | Definite Purpose Starter, 30A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO32V09![Square D 8911DPSO42V09 Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-8911dpso42v09_large.png?v=1720019289)
8911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO42V09![Square D 9001BWAEQ3439G3 PENDANT STATION 600VAC 5A T-BW SPECIAL | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/SQD-9001BWAEQ3439G3_300x_97cfbbb7-eac5-4e37-90e3-59db092b82f0_large.jpg?v=1715270770)
9001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G3People Also Searched
LC1D40M7
Square D LC1D40M7
LC1D40M7 price
Square D LC1D40M7 price