P4-14 | PPS piston flow switch | actuation set point .75 GPM (2.84 LPM) | SPST | NO switch. | Dwyer (OBSOLETE)
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!

Speak With a Technical Expert

Image for Technical Expert

P4-14 | PPS piston flow switch | actuation set point .75 GPM (2.84 LPM) | SPST | NO switch. | Dwyer (OBSOLETE)

PPS piston flow switch, actuation set point .75 GPM (2.84 LPM), SPST, NO switch.

Brand: DwyerSKU: P4-14
Dwyer | P4-14
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to P4-14

Overview Details for P4-14

DISCONTINUED MODEL, CONTACT TECHNICAL SUPPORT FOR REPLACEMENT OPTIONS See catalog product page for full listing

PPS piston flow switch | actuation set point .75 GPM (2.84 LPM) | SPST | NO switch.

Series P4 PPS Piston Flow Switch

Fixed Set Points from 0.1 to 1.5 GPM, SPST and SPDT Switching, Optional Adapters

The Series P4 PPS Flow Switch features a molded plastic construction for enhanced performance. Monitor liquids with fixed set points from 0.1 to 1.5 GPM. Choose normally open or normally closed SPST or SPDT hermetically sealed reed switch technology. The industrial switch features PPS (polyphenylene sulfide) R4 housing and piston, 316SS spring, fluoroelastomer O-ring and Epoxy. The inlet and outlet ports are 9/16"-18 UNF- 2B thread with optional 1/8" and 1/4" NPT or 1/2" barbed adapters.

Specifications

Series
P4 PPS Piston Flow Switch
Category/Type
Flow
Type
Flow Switches
Series
P4 PPS Piston Flow Switch
Service
Compatible liquids.
Wetted Materials
Housing and Piston: PPS (polyphenylene sulfide) R4; Spring: 316 SS; O-ring: Fluoroelastomer; Other: Epoxy.
Temperature Limits
0 to 225°F (17 to 107°C).
Pressure Limits
250 psig (17 bar) @ 54°F (12°C).
Accuracy
±15% of set point.
Repeatability
±1%.
Switch Type
SPST or SPDT.
Electrical Rating
.17 A @ 120 VAC; .08 A @ 240 VAC; .13 A @ 120 VDC; .06 A @ 240 VDC.
Electrical Connection
18 AWG; 24" (60.96 cm); PVC lead wires.
Process Connection
9/16-18 UNF-2B or choice of connection adapters (sold separately.)
Mounting Orientation
Any position. Set points shown are based on vertical; inlet down position.
Required Filtration
50 microns or better.
Weight
4 oz (0.11 kg).
Agency Approval
CE.