Series LTC2 Tilt Switch Control Unit
The Series LTC2 Tilt Probe Control Units feature an adjustable time delay and a logic selector switch. The logic selector switch determines when the output relay actuates and de-actuates, thus while in position one, the relay is energized when the probe is in the vertical position and de-energizes when the probe is in the titled position, and while in position two, the actions are opposite. In addition, an adjustable time-delay feature may be assigned to either the vertical or the tilt position to prevent false signals. The relay assumes the de-energized position upon reaching the end of the delay period as well as upon failure of power to the controller.
Product Applications
- Large hoppers
- Silos
- Crushers
- Trippers
- Stackers
- Conveyors
- Adjustable time delay feature may be assigned to either the vertical or the tilt position to prevent false signals
- Logic selector switch determines when the output relay actuates and deactuates, thus while in position one, the relay is energized when the probe is in the vertical position and de-energizes when the probe is in the titled position, and while in position two, the actions are opposite
- Relay assumes the de-energized position upon reaching the end of the delay period as well as upon failure of power to the controller
Specifications
- Series
- LTC2 Tilt Switch Control Unit
- Category/Type
- Level
- Type
- Level Switches
- Series
- LTC2 Tilt Switch Control Unit
- Temperature Limit
- -4 to 104°F (-20 to 40°C).
- Power Requirements
- 115 VAC @ 50/60 Hz.
- Power Consumption
- 10W.
- Switch Type
- DPDT.
- Electrical Rating
- 5 A @ 120 VAC; 5 A @ 240 VAC.
- Enclosure
- Cast aluminum.
- Enclosure Rating
- None or NEMA 4; 4X.
- Electrical Connections
- No suffix: 120 VAC; B suffix: 240 VAC.
- Conduit Connections
- 3/4 NPT: 2 power/relay & 1 probe.
- Indicator Light
- Green (when relay is energized and probe vertical); Red (whenrelay is de-energized and probe tilted); LED lamps.
- Time Delay
- 0.1 to 35 sec; Adjustment will delay output relay action.