Scroll to view all
Get your Special Pricing!
Documents: METSEEM4236B101
METSEEM4236B101 | Enercept Meter, class 0.2S, Modbus/BACnet RS485, Split Core 100A, ANSI wire code | Square D
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to METSEEM4236B101
Overview Details for METSEEM4236B101
Enercept Meter, class 0.2S, Modbus/BACnet RS485, Split Core 100A, ANSI wire code
The PowerLogic EM4200 Series Enercept power and energy meter is a unique compact retrofit solution for measuring energy data. This bundle ships with 3, 100 A split-core current transformers. Accuracy calibrated at 1%. ANSI version, fuse packs factory mounted. Designed for simplicity, the EM4200 has flexibility of a wide range of Current Transducers to match most applications from 50-5000A. This billing-rated, four-quadrant meter offers BACnet and Modbus communication protocols and supply power options from 90-480VAC. ANSI C12.1 rated and UL 61010-1.Specifications
- range
- PowerLogic
- product name
- PowerLogic EM4200
- device short name
- Enercept
- Product or Component Type
- Energy meter
- Type of Cable
- ANSI cable
- Device Application
- Power monitoring
- metering type
- Active;reactive;apparent energy (signed;four quadrant);Apparent power S;S1;S2;S3;Demand power P;Q;S;Active power P;P1;P2;P3;Reactive power Q;Q1;Q2;Q3;Power factor;Average current Iavg;Peak demand power PM;QM;SM;Frequency;Voltage U21;U32;U13;V1;V2;V3
- accuracy class
- Class 1 ANSI C12.1;Class 1S IEC 62053-22
- measurement accuracy
- 1 %
- measurement current
- 0…100 A
- measurement voltage
- 90 V AC 45...65 Hz minimum per phase;480 V AC 45...65 Hz between phases;300 V AC 45...65 Hz between phase and neutral
- frequency measurement range
- 45…65 Hz
- Network Frequency
- 50 Hz;60 Hz
- Line Rated Current
- 100 A
- Display Type
- Without Display
- local signalling
- Status LED green and red);Line fault 3 LED green;orange and red);Dial pointer indication LED Yellow);RX/TX 2 LED green;orange and red)
- Signal
- split core current transducer 0.333 V 33 kOhm);voltage single phase 2.5 MOhm);voltage phase to phase 5 MOhm)
- number of inputs
- 0
- Number of Outputs
- 0
- communication port protocol
- Modbus RTU 9600 bauds...115200 bauds (automatic detection);BACnet MS/TP 9600 bauds...115200 bauds (automatic detection)
- communication of data
- Remote control orders;Total energy;Net energy
- Demand intervals
- External synchronisation to communication;Fixed or rolling block
- provided equipment
- Bracket for support;Hook;Split core current transducer 3;Fuse
- connections - terminals
- Input/output plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²);Current transformer plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²);Communication plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²)
- wire stripping length
- 0.24 in (6 mm)
- Mounting Mode
- By screws;Clip-on;By hook
- mounting support
- Enclosure;DIN rail
- Standards
- EN 61010-1;UL 61010-1;CAN/CSA C22.2 No. 61010-1-12
- product certifications
- CE EN 61010-1;CULus UL 61010-1;BTL;ANSI
- Width
- 1.84 in (46.63 mm)
- depth
- 1.41 in (35.81 mm)
- Height
- 6.00 in (152.36 mm)
- measurement category
- Category III 277 V;Category III 300 V
- electromagnetic compatibility
- Conducted and radiated emissions FCC Part 15 class A;Conducted and radiated emissions EN 61000-6-4;Conducted and radiated emissions EN 61326 + A1;Immunity to conducted disturbances EN 61000-6-2;Immunity to conducted disturbances EN 61326-1;Immunity to radiated fields EN 61000-6-2;Immunity to radiated fields EN 61326-1
- IP degree of protection
- IP20 IEC 60529
- relative humidity
- 0…95 %
- pollution degree
- 2
- ambient air temperature for operation
- -22…158 °F (-30…70 °C)
- Ambient Air Temperature for Storage
- -40…185 °F (-40…85 °C)
- Operating altitude
- < 9842.52 ft (3000 m)
- Category
- 09791-POWERLOGIC ENERCEPT POWER METER
- Discount Schedule
- PL1
- GTIN
- 3606489564698
- Returnability
- No
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Weight
- 53.55 oz (1518.18 g)