Get Special Pricing!
LTMEV40FM | Motor Management, TeSys T, extension module, 4 inputs, for LTMR controller, 100 to 240 VAC | Square D by Schneider Electric
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LTMEV40FM
Overview
Details for LTMEV40FM
Motor Management, TeSys T, extension module, 4 inputs, for LTMR controller, 100 to 240 VAC
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 120 to 240 VAC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.Specifications
- Range
- TeSys
- Product name
- TeSys T
- device short name
- LTME
- Product or component type
- Extension module
- device application
- Equipment monitoring and control
- Range compatibility
- TeSys (TeSys T) LTMR motor controller
- Supply
- Via the controller
- [Ui] rated insulation voltage
- 690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508 - [Uimp] rated impulse withstand voltage
- 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 - Logic input number
- 4
- Input current
- 3.1 mA at 100 V
7.5 mA at 240 V - Current state 0 guaranteed
- Logic input: 0...40 V and 2...15 mA for 25 ms
- Current state 1 guaranteed
- Logic input: 79...264 V and <= 15 mA for 25 ms
- maximum output switching frequency
- 2 Hz
- maximum operating rate
- 1800 cyc/h
- Contacts type and composition
- Without
- Metering type
- Imbalance voltage
Active power P, P1, P2, P3
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Voltage U21, U32, U13, V1, V2, V3
Reactive power Q, Q1, Q2, Q3
Frequency
Power factor - Measurement accuracy
- 1 % voltage (100...830 V)
3 % power factor
5 % active and reactive power - Overvoltage category
- III
- Connection pitch
- 5.08 mm
- Connections - terminals
- Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end - Tightening torque
- Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
- Pollution degree
- 3
- Electromagnetic compatibility
- Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 - Width
- 45 mm
- Height
- 61 mm
- Depth
- 120.7 mm
- Net weight
- 0.21 kg
- Compatibility code
- LTME
- Standards
- CSA C22.2 No 14
IACS E10
IEC 60947-4-1
UL 508
EN 60947-4-1 - product certifications
- LROS (Lloyds register of shipping)
ATEX
NOM
EAC
RMRoS
GL
UL
DNV
BV
RINA
KERI
C-Tick
CSA
CCC
ABS - IP degree of protection
- IP20
- Protective treatment
- 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068 - Fire resistance
- 650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94 - Ambient air temperature for operation
- -20…60 °C
- Ambient air temperature for storage
- -40…80 °C
- Operating altitude
- <= 2000 m without derating
- Mechanical robustness
- Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 - Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 5.5 cm
- Package 1 Width
- 7.2 cm
- Package 1 Length
- 13.6 cm
- Package 1 Weight
- 200 g
- Unit Type of Package 2
- S02
- Number of Units in Package 2
- 20
- Package 2 Height
- 15 cm
- Package 2 Width
- 30 cm
- Package 2 Length
- 40 cm
- Package 2 Weight
- 4.385 kg
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
![Square D 171CBU98090 UNITY M1E SERIAL 232/485 | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-171cbu98090_951adf2b-795f-4ac5-ac3d-bb93d6599bea_large.png?v=1720094843)
171CBU98090 | UNITY M1E SERIAL 232/485 | Square D by Schneider Electric
Brand: Square D
SKU: 171CBU98090![Square D 2601AG2 DRUM SWITCH 600VAC 2HP A +OPTION | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-2601ag2_9e868e65-1227-4ca2-9f22-aaaeeb6be3a5_large.png?v=1720094843)
2601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D by Schneider Electric
Brand: Square D
SKU: 2601AG2![Square D 8911DPSO32V09 Definite Purpose Starter, 30A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-8911dpso32v09_large.png?v=1720019268)
8911DPSO32V09 | Definite Purpose Starter, 30A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO32V09![Square D 8911DPSO42V09 Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/se-8911dpso42v09_large.png?v=1720019289)
8911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO42V09![Square D 9001BWAEQ3439G3 PENDANT STATION 600VAC 5A T-BW SPECIAL | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/SQD-9001BWAEQ3439G3_300x_97cfbbb7-eac5-4e37-90e3-59db092b82f0_large.jpg?v=1715270770)
9001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G3People Also Searched
LTMEV40FM
Square D LTMEV40FM
LTMEV40FM price
Square D LTMEV40FM price