GV4P115N | Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: GV4P115N

Web Price:

$769.99
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

GV4P115N | Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals | Square D by Schneider Electric

Square D | GV4P115N
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to GV4P115N

Documents and manuals

Square D GV4P115N Documents

Overview

Details for GV4P115N

Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Specifications

Range of Product
TeSys GV4
range
TeSys Deca;TeSys Deca
device short name
GV4P
product name
TeSys GV4;TeSys Deca
Product or Component Type
Motor circuit breaker
Device Application
Motor protection
trip unit technology
Electronic;Thermal-magnetic
poles description
3P
utilisation category
Category A IEC 60947-2;AC-3 IEC 60947-4-1
operating position
Any position
motor power kW
37 kW 400...415 V AC 50/60 Hz;45 kW 400...415 V AC 50/60 Hz;55 kW 400...415 V AC 50/60 Hz;45 kW 500 V AC 50/60 Hz;55 kW 500 V AC 50/60 Hz;75 kW 500 V AC 50/60 Hz;75 kW 660...690 V AC 50/60 Hz;90 kW 660...690 V AC 50/60 Hz;110 kW 660...690 V AC 50/60 Hz
breaking capacity
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2;50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2;50 kA Icu 440 V AC 50/60 Hz IEC 60947-2;15 kA Icu 525 V AC 50/60 Hz IEC 60947-2;65 kA 208Y/120 V AC 50/60 Hz UL 60947;65 kA 240 V AC 50/60 Hz UL 60947;35 kA 480Y/277 V AC 50/60 Hz UL 60947;8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2;25 kA Icu 500 V AC 50/60 Hz IEC 60947-2;18 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type
Rotary handle
Line Rated Current
115 A
magnetic tripping current
1955 A
[Ue] rated operational voltage
690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage
800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current
115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage
8 kV IEC 60947-2
power dissipation per pole
4.6 W
mechanical durability
40000 cycles
electrical durability
10000 cycles AC-3 440 V In/2;5000 cycles AC-3 440 V In
maximum operating rate
25 cyc/h
rated duty
Continuous IEC 60947-4-1
connections - terminals
EverLink BTR screw connectors top) 1 0.00…0.11 in² (1.5…70 mm²) - solid;EverLink BTR screw connectors top) 1 0.00…0.08 in² (1.5…50 mm²) - flexible;EverLink BTR screw connectors bottom) 1 0.00…0.15 in² (2.5…95 mm²) - solid;EverLink BTR screw connectors bottom) 1 0.00…0.11 in² (2.5…70 mm²) - flexible
tightening torque
79.66 lbf.in (9 N.m) 0.02…0.15 in² (16…95 mm²);44.25 lbf.in (5 N.m) 0.00…0.02 in² (1.5…10 mm²)
mechanical robustness
Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6;Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6;Shocks 15 gn 11 ms IEC 60068-2-27
phase failure sensitivity
Yes IEC 60947-4-1
Height
6.10 in (155 mm)
Width
3.19 in (81 mm)
Depth
6.50 in (165 mm)
Net Weight
3.53 lb(US) (1.6 kg)
color
Gray RAL 7016)
suitability for isolation
Yes IEC 60947-1
Standards
CSA C22.2 No 60947-4-1;UL 60947-4-1;EN/IEC 60947-4-1;EN/IEC 60947-2
Product Certifications
IEC;UL;CSA;CCC;EAC;ATEX;EU-RO MR
climatic withstand
IACS E10
IK degree of protection
IK07 IEC 62262
pollution degree
3
IP degree of protection
IP40 IEC 60529
Ambient Air Temperature for Storage
-58…185 °F (-50…85 °C)
fire resistance
1760 °F (960 °C) IEC 60695-2-11
operating altitude
5000 m
ambient air temperature for operation
-13…158 °F (-25…70 °C)
Category
22365-TESYS GV4 MOTOR CIRCUIT BREAKERS
Discount Schedule
I11
GTIN
3606481310385
Returnability
No
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
8.27 in (21.0 cm)
Package 1 Width
4.33 in (11.0 cm)
Package 1 Length
8.66 in (22.0 cm)
Package 1 Weight
4.08 lb(US) (1.85 kg)
Unit Type of Package 2
S03
Number of Units in Package 2
3
Package 2 Height
11.81 in (30.0 cm)
Package 2 Width
11.81 in (30.0 cm)
Package 2 Length
15.75 in (40.0 cm)
Package 2 Weight
13.23 lb(US) (6.0 kg)
Warranty
18 months

Reviews

People Also Searched