Zelio Time Delay Relay, 10 Functions, 8A, 24-240V AC 50/60Hz, 24V DC, 1s-100h
Zelio Time Delay RelaySpecifications
- Range of Product
- Harmony Timer Relays
- Product or Component Type
- Multifunction relay
- discrete output type
- Relay
- Width
- 0.69 in (17.5 mm)
- device short name
- RE17R
- time delay type
- Power on-delay;On-delay and off-delay;Interval;Off-delay;Symmetrical flashing
- time delay range
- 6...60 min;1...10 h;0.1...1 s;1...10 s;1...10 min;10...100 h;6...60 s
- nominal output current
- 8 A
- contacts type and composition
- 1 C/O
- contacts material
- Cadmium free
- Height
- 3.54 in (90 mm)
- Depth
- 2.83 in (72 mm)
- control type
- Selector switch front panel
- [Us] rated supply voltage
- 24...240 V AC 50/60 Hz;24 V DC
- voltage range
- 0.85...1.1 Us
- supply frequency
- 50...60 Hz +/- 5 %
- release of input voltage
- 10 V
- connections - terminals
- Screw terminals;1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end;Screw terminals;2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end;Screw terminals;1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end;Screw terminals;2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- tightening torque
- 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
- housing material
- Self-extinguishing
- repeat accuracy
- +/- 0.5 % IEC 61812-1
- Temperature Drift
- +/- 0.05 %/°C
- voltage drift
- +/- 0.2 %/V
- setting accuracy of time delay
- +/- 10 % of full scale 25 °C IEC 61812-1
- control signal pulse width
- 100 ms with load in parallel typical;30 ms typical
- insulation resistance
- 100 MOhm 500 V DC IEC 60664-1
- reset time
- 120 ms on de-energisation typical
- on-load factor
- 100 %
- power consumption in VA
- 0…32 VA 240 V AC
- maximum power consumption in W
- 0.6 W 24 V DC
- minimum switching current
- 10 mA 5 V DC
- maximum switching current
- 8 A AC/DC
- maximum switching voltage
- 250 V AC
- breaking capacity
- 2000 VA
- operating frequency
- 10 Hz
- electrical durability
- 100000 cycles resistive 8 A 250 V AC
- mechanical durability
- 10000000 cycles
- dielectric strength
- 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
- [Uimp] rated impulse withstand voltage
- 5 kV 1.2/50 µs
- power on delay
- 100 ms
- Marking
- CE
- creepage distance
- 4 kV/3 IEC 60664-1
- safety reliability data
- B10d = 270000;MTTFd = 296.8 years
- mounting position
- Any position in relation to normal vertical mounting plane
- mounting support
- 35 mm DIN rail conforming to EN/IEC 60715
- local signalling
- LED indicator on steady: relay energised;no timing in progress;LED indicator 80 % ON and 20 % OFF flashing: timing in progress;LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised;no timing in progress (except function Di-D;Li-L)
- Net Weight
- 0.15 lb(US) (0.07 kg)
- time delay type
- A;Ac;At;B;Bw;C;D;Di;H;Ht
- functionality
- Multifunction
- compatibility code
- RE17
- immunity to microbreaks
- 20 ms
- Standards
- 2006/95/EC;2004/108/EC;IEC 61812-1;EN 61000-6-2;EN 61000-6-3;EN 61000-6-4;EN 61000-6-1
- Product Certifications
- CSA;GL;cULus
- Ambient Air Temperature for Storage
- -22…140 °F (-30…60 °C)
- Ambient Air Temperature for Operation
- -4…140 °F (-20…60 °C)
- IP degree of protection
- IP20 IEC 60529 terminal block);IP40 IEC 60529 housing);IP50 IEC 60529 front panel)
- vibration resistance
- 20 m/s² 10…150 Hz)IEC 60068-2-6
- shock resistance
- 15 gn 11 ms IEC 60068-2-27
- Relative Humidity
- 93 % without condensation IEC 60068-2-30
- electromagnetic compatibility
- Electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2;Electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2;Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3;Electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4;Electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4;1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5;1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5;Conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6;Voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11;Voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11;Conducted and radiated emissionsclass B EN 55022
- Category
- 22370-RE;RM MISC TIMERS & COUNTERS
- Discount Schedule
- CP2
- GTIN
- 00785901543633
- Returnability
- Yes
- Country of origin
- ID
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 1.02 in (2.6 cm)
- Package 1 Width
- 3.07 in (7.8 cm)
- Package 1 Length
- 3.74 in (9.5 cm)
- Package 1 Weight
- 2.75 oz (78.0 g)
- Unit Type of Package 2
- S02
- Number of Units in Package 2
- 40
- Package 2 Height
- 5.91 in (15.0 cm)
- Package 2 Width
- 11.81 in (30.0 cm)
- Package 2 Length
- 15.75 in (40.0 cm)
- Package 2 Weight
- 8.41 lb(US) (3.813 kg)
- Unit Type of Package 3
- P06
- Number of Units in Package 3
- 640
- Package 3 Height
- 30.31 in (77.0 cm)
- Package 3 Width
- 31.50 in (80.0 cm)
- Package 3 Length
- 23.62 in (60.0 cm)
- Package 3 Weight
- 144.84 lb(US) (65.7 kg)