Details for LTMR08PFM
TeSys T Motor Controller, 8A, 100-240V AC, Profibus DP, IP20
TeSys T Motor Controller- Measurement Current: 0.4-8A
- Rated Supply Voltage: 100-240V AC 50/60 Hz
- Communication Port Protocol: Profibus DP
- Degree of Protection: IP20
Specifications
- range
- TeSys
- product name
- TeSys T
- device short name
- LTMR
- Product or Component Type
- Motor controller
- Device Application
- Equipment monitoring and control
- measurement current
- 0.4…8 A
- [Us] rated supply voltage
- 100...240 V AC 50/60 Hz
- Current Consumption
- 8...62.8 mA
- supply voltage limits
- 93.5…264 V AC
- Communication Port Protocol
- Profibus DP
- bus type
- Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s;SUB-D 9 2 shielded twisted pairs;type A;Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s;terminal block 2 shielded twisted pairs;type A
- [Ui] rated insulation voltage
- 690 V EN/IEC 60947-1;690 V CSA C22.2 No 14;690 V UL 508
- [Uimp] rated impulse withstand voltage
- 4 kV supply;inputs and outputs EN/IEC 60947-4-1;6 kV current or voltage measurement circuit EN/IEC 60947-4-1;0.8 kV communication circuit EN/IEC 60947-4-1
- short-circuit withstand
- 100 kA EN/IEC 60947-4-1
- associated fuse rating
- 4 A gG output;0.5 A gG control circuit
- Protection Type
- Locked rotor;Overload;Phase unbalance;Phase failure;Earth-leakage protection;Reverse polarity protection;Load fluctuation;Thermal protection;Power factor variation;Thermal overload protection;Overload (long time)
- network and machine diagnosis type
- Phase fault and earth fault trip counters;Trip history information;Starting current and time;Fault recording;Waiting time after overload tripping;Event recording;Motor control command recording;Running hours counter/operating time;Trip context information;Remaining operating time before overload tripping
- logic input number
- 6
- input current
- 3.1 mA 100 V;7.5 mA 240 V
- current state 0 guaranteed
- Logic input 0...40 V <= 15 mA 25 ms
- current state 1 guaranteed
- Logic input 79...264 V >= 2 mA 25 ms
- maximum output switching frequency
- 2 Hz
- load current
- 5 A 250 V AC logic output;5 A 30 V DC logic output
- permissible power
- 480 VA AC-15);Ie = 2 A;500000 cycles output);30 W DC-13);Ie = 1.25 A;500000 cycles output)
- maximum operating rate
- 1800 cyc/h
- contacts type and composition
- 1 NO + 1 NC fault signal;3 NO
- metering type
- Average current Iavg;Earth-fault current;Temperature;Imbalance current;Phase current I1;I2;I3 RMS
- measurement accuracy
- 5...15 % earth fault current internal measurement;1 % voltage 100...830 V);3 % power factor;5 % earth fault current external measurement;+/- 30 min/year internal clock;0;02 Temperature;1 % current;5 % active and reactive power
- overvoltage category
- III
- connection pitch
- 0.20 in (5.08 mm)
- connections - terminals
- Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end;Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end;Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end;Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end;Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end;Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end;Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end;Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end
- tightening torque
- Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
- pollution degree
- 3
- electromagnetic compatibility
- Electrostatic discharge;3 8 kV air;6 kV contact)EN/IEC 61000-4-2);Radiated RF fields;3 10 V/m)EN/IEC 61000-4-3);Fast transients immunity test;level 3 2 kV)EN/IEC 61000-4-4);Fast transients immunity test;level 4 4 kV)EN/IEC 61000-4-4);Voltage dips and interruptions immunity test 70 %;500 ms)EN/IEC 61000-4-11);Conducted RF disturbances 10 V)EN/IEC 61000-4-6);Surges 0.5 kV)EN/IEC 61000-4-5);Surges 1 kV)EN/IEC 61000-4-5);Surges 1 kV)EN/IEC 61000-4-5);Surges 2 kV)EN/IEC 61000-4-5);Surges 2 kV)EN/IEC 61000-4-5);Surges 4 kV)EN/IEC 61000-4-5);Surges 2 kV)EN/IEC 61000-4-5)
- Width
- 3.58 in (91 mm)
- Height
- 2.40 in (61 mm)
- Depth
- 4.82 in (122.5 mm)
- Net Weight
- 1.17 lb(US) (0.53 kg)
- web services
- Web server
- compatibility code
- LTMR
- Standards
- UL 508;IEC 60947-4-1;EN 60947-4-1;IACS E10;CSA C22.2 No 14
- Product Certifications
- CSA;C-tick;UL;CCC;LROS (Lloyds register of shipping);NOM;ABS;GL;EAC;BV;DNV;RINA;RMRoS;ATEX;KERI
- protective treatment
- 12 x 24 hour cycles EN/IEC 60068-2-30;48 h EN/IEC 60070-2-11;TH EN/IEC 60068
- fire resistance
- 1202 °F (650 °C) EN/IEC 60695-2-12;1760 °F (960 °C) UL 94
- ambient air temperature for operation
- -4…140 °F (-20…60 °C)
- Ambient Air Temperature for Storage
- -40…176 °F (-40…80 °C)
- operating altitude
- <= 6561.68 ft (2000 m) without derating
- mechanical robustness
- Vibrations mounted on symmetrical rail1 Gn;5...300 Hz EN/IEC 60068-2-6;Vibrations plate mounted4 Gn;5...300 Hz EN/IEC 60068-2-6;Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
- IP Degree of Protection
- IP20
- Category
- 22338-SOLID STATE OVERLOAD RELAYS
- Discount Schedule
- I12
- GTIN
- 3389119404815
- Returnability
- Yes
- Country of origin
- CN
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 2.83 in (7.2 cm)
- Package 1 Width
- 3.94 in (10 cm)
- Package 1 Length
- 5.35 in (13.6 cm)
- Package 1 Weight
- 18.55 oz (526 g)
- Unit Type of Package 2
- S02
- Number of Units in Package 2
- 10
- Package 2 Height
- 5.91 in (15 cm)
- Package 2 Width
- 11.81 in (30 cm)
- Package 2 Length
- 15.75 in (40 cm)
- Package 2 Weight
- 12.47 lb(US) (5.656 kg)
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
171CBU98090 | UNITY M1E SERIAL 232/485 | Square D by Schneider Electric
Brand: Square D
SKU: 171CBU980902601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D by Schneider Electric
Brand: Square D
SKU: 2601AG28911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO42V099001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G3People Also Searched
LTMR08PFM
Square D LTMR08PFM
LTMR08PFM price
Square D LTMR08PFM price