Details for LP4K1201BW3
TeSys K contactor, 3P, AC-3= 440 V 12 A, 1 NC aux, 24 V DC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V). It provides a low consumption 24V DC coil with transient suppressor module, 1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).Specifications
- Range of Product
- TeSys K
- range
- TeSys
- Product or Component Type
- Contactor
- device short name
- LP4K
- contactor application
- Resistive load;Motor control
- utilisation category
- AC-1;AC-4;AC-3;AC-3e
- poles description
- 3P
- pole contact composition
- 3 NO
- [Ie] rated operational current
- 20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit;12 A<= 440 V AC AC-3 power circuit;16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit;12 A<= 440 V AC AC-3e power circuit
- auxiliary contact composition
- 1 NC
- coil technology
- Built-in bidirectional peak limiting diode suppressor
- auxiliary contacts type
- Instantaneous 1 NC
- control circuit voltage limits
- Operational 0.7...1.30 Uc 122 °F (50 °C));Drop-out 0.1...0.7 Uc 122 °F (50 °C))
- [Ui] rated insulation voltage
- Power circuit 600 V UL 508;Power circuit 690 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-5-1;Signalling circuit 600 V UL 508;Power circuit 600 V CSA C22.2 No 14;Signalling circuit 600 V CSA C22.2 No 14
- [Uimp] rated impulse withstand voltage
- 8 kV
- overvoltage category
- III
- Mounting Support
- Rail;Plate
- flame retardance
- V1 conforming to UL 94;Requirement 2 conforming to NF F 16-101;Requirement 2 conforming to NF F 16-102
- tightening torque
- 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2;7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm;7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
- [Ue] rated operational voltage
- Power circuit 690 V AC 50/60 Hz;Signalling circuit <= 690 V AC 50/60 Hz
- [Ith] conventional free air thermal current
- 20 A 122 °F (50 °C) power circuit;10 A 122 °F (50 °C) signalling circuit
- Irms rated making capacity
- 110 A AC signalling circuit IEC 60947;144 A AC power circuit NF C 63-110;144 A AC power circuit IEC 60947
- rated breaking capacity
- 110 A 440 V IEC 60947;80 A 500 V IEC 60947;70 A 660...690 V IEC 60947
- associated fuse rating
- 25 A gG <= 440 V power circuit;25 A aM power circuit;10 A gG signalling circuit IEC 60947;10 A gG signalling circuit VDE 0660
- average impedance
- 3 mOhm - Ith 20 A 50 Hz power circuit
- inrush power in W
- 1.8 W 68 °F (20 °C))
- hold-in power consumption in W
- 1.8 W 68 °F (20 °C)
- operating time
- 10...20 ms coil de-energisation and NO opening;30...40 ms coil energisation and NO closing
- safety reliability level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- mechanical durability
- 30 Mcycles
- maximum operating rate
- 3600 cyc/h
- minimum switching current
- 5 mA signalling circuit
- minimum switching voltage
- 17 V signalling circuit
- insulation resistance
- > 10 MOhm signalling circuit
- Height
- 2.28 in (58 mm)
- Width
- 1.77 in (45 mm)
- Depth
- 2.24 in (57 mm)
- Net Weight
- 0.52 lb(US) (0.235 kg)
- Product Certifications
- UL;CSA;UKCA
- Ambient air temperature for operation
- -13…122 °F (-25…50 °C)
- Ambient Air Temperature for Storage
- -58…176 °F (-50…80 °C)
- operating altitude
- 6561.68 ft (2000 m) without derating
- Category
- 22321-CTR;K-LINE;DC;OPEN;NONREV
- Discount Schedule
- I12
- GTIN
- 3389110791167
- Returnability
- Yes
- Country of origin
- FR
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 1.89 in (4.8 cm)
- Package 1 Width
- 2.44 in (6.2 cm)
- Package 1 Length
- 2.60 in (6.6 cm)
- Package 1 Weight
- 7.72 oz (219 g)
- Unit Type of Package 2
- S02
- Number of Units in Package 2
- 40
- Package 2 Height
- 5.91 in (15 cm)
- Package 2 Width
- 11.81 in (30 cm)
- Package 2 Length
- 15.75 in (40 cm)
- Package 2 Weight
- 20.26 lb(US) (9.192 kg)
- Unit Type of Package 3
- P06
- Number of Units in Package 3
- 320
- Package 3 Height
- 17.72 in (45 cm)
- Package 3 Width
- 31.50 in (80 cm)
- Package 3 Length
- 23.62 in (60 cm)
- Package 3 Weight
- 181.26 lb(US) (82.22 kg)
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
2601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D
Brand: Square D
SKU: 2601AG28911DPSO32V09 | Definite Purpose Starter, 30A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D
Brand: Square D
SKU: 8911DPSO32V098911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D
Brand: Square D
SKU: 8911DPSO42V099001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G39001K35 | Joystick Controller - 30mm - 5 Positions Spring Return - Without Contact | Square D
Brand: Square D
SKU: 9001K35People Also Searched
LP4K1201BW3
Square D LP4K1201BW3
LP4K1201BW3 price
Square D LP4K1201BW3 price