Documents: RHP-2E44
RHP-2E44 | European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature | Dwyer
European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature
Overview Details for RHP-2E44
European Wall Mount Humidity / Temperature Transmitter with 2% accuracy and universal current / voltage output for RH and Temperature
Series RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter
The Series RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitteris the most versatile room transmitter on the market. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. The humidity and the dew point are measured using a capacitive polymer sensorthat completely recovers from 100% saturation. The humidity and dew point canhave either a current or voltage output, while the optional temperature output canbe a current, voltage, RTD or thermistor. For models with current or voltage for thetemperature output, the temperature range is field selectable.
For models with resistive thermistors or RTD outputs, please click here for temperature to resistance lookup tables.
Product Applications
- Air economizers
- Room comfort monitoring
- Greenhouse monitoring
- Field selectable relative humidity or dew point output
- Universal analog outputs
- Integral or service tool LCD display options
- Two housing designs to match North American and European aesthetics
Specifications
- Series
- RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter
- Category/Type
- Air Quality
- Type
- Humidity / Temperature Transmitters
- Series
- RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter
- Relative Humidity Range
- 0 to 100% RH.
- Temperature Range
- -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors.-20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors.
- Dew Point Temperature Range
- -20 to 140°F (-28.9 to 60°C); 0 to 100°F(-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectableranges.
- Accuracy
- RH: Model RHP-2XXX ±2% 10 to 90% RH @ 25°C; Model RHP-3XXX ±3% 20 to80% RH @ 25°C; Model RHP-5XXX ±5% 20 to 80% RH @ 25°C;Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C);RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C);Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C).
- Hysteresis
- ±.8%.
- Repeatability
- ±0.1% typical.
- Temperature Limits
- Operating: -40 to 140°F (-40 to 60°C);Storage: -40 to 176°F (-40 to 80°C).
- Compensated Temperature Range
- -4 to 140°F (-20 to 60°C).
- Power Requirements
- 4-20 mA loop powered outputs: 10-35 VDC; 0-5/10Voutputs: 15-35 VDC or 15-29 VAC.
- Output Signals
- 4-20 mA loop powered outputs: 4-20 mA; 2 channels for humidity/solid state temperature sensor models (loop powered on RH). Switch selectableRH/dew point. Switch selectable normal or reverse output; 0-5/10V outputs: 5mA max.; 2 channels for humidity/solid state temperature sensor models. Switchselectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point.Switch selectable normal or reverse output.
- Solid State Band Gap Temp Sensor Output Ranges
- Switch selectable; -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to32.3°C); -4 to 140°F (-20 to 60°C).
- Response Time
- 8 s.
- Electrical Connections
- Screw terminal block.
- Drift
- <.25% RH/year.
- RH Sensor
- Capacitance polymer.
- Enclosure Material
- Polycarbonate.
- Enclosure Rating
- IP20.
- Display
- Optional LCD; Switch selectable %RH or dew point; °F/°C.
- Display Resolution
- RH: 1%; Temperature: 0.1°F (0.1°C); Dew Point: 1°F (1°C).
- Weight
- 4.4 oz (125 g).
- Agency Approvals
- CE.