Scroll to view all
Get your Special Pricing!
Documents: GFC-2101
GFC-2101 | Gas mass flow controller | range 0-10 mL/m. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting. | Dwyer
Gas mass flow controller, range 0-10 mL/m. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" compression fitting.
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to GFC-2101
Overview Details for GFC-2101
See catalog product page for full listing
Gas mass flow controller | range 0-10 mL/m. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting.
Series GFC Gas Mass Flow Controllers
Flow Range Up to 1000 L/min, Pressures Up to 1000 psi, NIST Traceable
The Series GFC Gas Mass Flow Controllers combine a straight tube sensor with a restrictor flow element. It is available for flow ranges up to 1000 L/min and offered in aluminum or 316 SS in 1/4", 3/8", 1/2" and 3/4" sizes.
Product Applications
- Gas flow measurement
- Gas flow control
- Operating pumps and valves
- Process equipment
- Vacuum processes
- Glass and metal coating
- Film depostition
- Provides high accuracy and repeatability
- Flow rates are virtually unaffected by temperature and pressure variations
- Utilizes an electromagnetic valve and PID electronics to maintain continuous controlby comparing measured sensor signal set to flow rates
- Set points can be adjusted with local potentiometers or remotely via 0 to 5 VDC or 4to 20 mA analog signal
- Actual gas flow is displayed in engineering units on a 3-1/2 digit, 90° tiltable LCDreadout
- Can be used with Series GFT2 Flow Totalizer for applications requiring totalization
- NIST traceable certificate included
Specifications
- Series
- GFC Gas Mass Flow Controllers
- Category/Type
- Flow
- Type
- Mass Flowmeters and Controllers
- Series
- GFC Gas Mass Flow Controllers
- Service
- Clean gases compatible with wetted parts.
- Wetted Materials
- GFC-1XXX: Anodized aluminum; brass; 316 SS and fluoroelastomer O-rings; GFC-2XXX: 316 SS and fluoroelastomer O-rings.
- Accuracy
- ±1% FS including linearity over 59 to 77°F (5 to 25°C) and 5 to 60 psia (0.34 to 4 bar); Series GFC X143; X144; X145; ±1.5% FS.
- Repeatability
- ±0.5% of FS.
- Response Time
- 2 seconds to within ±2% of actual flow.
- Output
- Linear 0 to 5 VDC and 4 to 20 mA.
- Maximum Particulate Size
- 5 microns.
- Temperature Limits
- 32 to 122°F (0 to 50°C).
- Power Supply
- ±12 VDC.
- Process Connections
- 1/4" compression fitting for flow rates ≤50 L/m; 3/8" for 100 and 200 L/m; 1/2" for 500 L/min; 3/4" for 1000 L/min.
- Pressure Limits
- 1000 psig (68.9 bar); Series GFC-X143; X144; X145; 500 psig (34.5 bar).
- Leak Integrity
- 1 x 10-9 sccs of He.
- Display
- 90° tiltable; 3-1/2 digit.
- Agency Approvals
- CE.