TSENSE | CO2 Carbon Dioxide Sensor | ACI
Carbon Dioxide Sensor, Analog, Modbus, or BACnet, RH/TEMP, RELAY
Documents and manuals
ACI TSENSE Documents
Overview
Details for TSENSE
TSENSE | CO2 Carbon Dioxide Sensor
CO2 Sensor with Temperature, RH & Display TSENSE is an advanced and versatile 3 in 1 transmitter. Designed for installation in the air conditioned zone, it measures CO2 concentration, temperature and humidity in the ambient air. The data is transmitted to a BMS system or stand-alone controller using industry standard output signals and communications protocols, including BACnet„¢. TSENSE combines all the necessary elements for effective climate control in commercial office buildings, hospitals, hotels, schools and other facilities, allowing for a comfortable and healthy environment for the occupants. It is flexible in design and is suitable for use in many different energy efficient ventilation strategies. 0 to 10 VDC outputs based on 0“2000 ppm, 32-122°F, 0-95% RH. Relay On/Off, based on 1000/900 ppm (CO2). Life expectancy based on 15 years (typical). Backlit LCD displays: CO2 (ppm), Temperature (°F), and Humidity (%RH). Touch display menu system Environmental conditions covered: Carbon Dioxide, Temperature, and Relative Humidity.
The two part numbers are TSENSE (no display) and TSENSE-LCD (with display).
Carbon Dioxide sensors or transmitters for HVAC, Building Automation Systems, or ANSI/ASHRAE Standard 62.1-2004. Typical applications include: schools, office buildings, auditoriums, gymnasiums, shopping malls, theatres, demand control ventilation, economizers.
- Combines CO2, Temperature, and Relative Humidity into one unit
- Bacnet or analog outputs
- User-friendly menu
Veris HWLP1T1, HWLP1T3, HWLP2T1, HWLP2XX, HWLPHTX,
Alerton BACtalk, WEBtalk, Viewport, Envision, Compass software
Honeywell Excel Web II, XL2026B2A, TB7600, Spyder BACnet
Reliable Controls MACH-System, MACH-Global, MACH-Zone, MACH-Net
Greystone HANTRC, HANTO, HANTD, NTO, NTD, CMD, CDD3, ULP, RPC, NTRC, UP, DWDT, ULP2-BAC, ULP1-BAC, CDD3A101S
Specifications
Item Number | TSENSE |
Brand | ACI |
Sensor | CO2 Carbon Dioxide |
Reviews
![Generic BACnet Router BACNET_ROUTER BACnet Router | Generic | BACnet/IP to BACnet/MSTP | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/bacnet-router-generic_bd39ca3a-7f46-4faf-af8a-c6f3e759224d_large.jpg?v=1719424200)
![Belimo AFB24-SR Damper Actuator | 180 in-lb | Spg Rtn | 24V | Modulating | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/AFB24-SR_Fail-Safe_Actuator-product_retina_85f5b354-c91b-4afb-9243-21848913f1c4_large.jpg?v=1716932361)
![Belimo AMB24-3 Damper Actuator | 180 in-lb | Non-Spg Rtn | 24V | On/Off/Floating Point | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/AMB..-3_Non_Fail-Safe_Actuators-product_retina_ddb2fbc7-a575-494b-ae22-6be278d1758d_large.jpg?v=1714682129)
![Belimo ARX24-MFT Valve Actuator | Non-Spg | 24V | MFT | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/ARQX24-MFT_web_911c9dd5-b995-4fee-ae67-e738d3460949_large.png?v=1714682163)
![Belimo B225+LF120 US CCV | 1" | 2 Way | 30 Cv | w/ Spg Rtn | 120V | On/Off | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/CCV_B2_LF-product_retina_9dbd98f7-4848-41e0-9f06-3c8fb7c8b5a3_large.jpg?v=1714682626)
![ACI PAM-1 Relay | 10 Amp | Coil: 24 VAC or VDC / 120 VAC | Blackhawk Supply](http://blackhawksupply.com/cdn/shop/files/aci-pam-1_large.jpg?v=1718739535)