A/MLP2-010-W-U-A-B-0P | Differential Pressure Sensor Transducer Unidirectional | 0-10" w.c. | 0-5 VDC | ACI

Differential Pressure, Panel Mount, 10.00 inWC, UniDirectional, +/- 0.5% FSO, 0-5VDC

Brand: ACISKU: A/MLP2-010-W-U-A-B-0P
ACI | A/MLP2-010-W-U-A-B-0P
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to A/MLP2-010-W-U-A-B-0P

Overview Details for A/MLP2-010-W-U-A-B-0P

A/MLP2-010-W-U-A-B-0P | Differential Pressure Sensor Transducer Unidirectional | 0-10" w.c. | 0-5 VDC

The MLP2 Series Low Differential Pressure transmitters are designed for use in OEM or high density panel mounting applications. Key installation features include an integral 35 mm DIN rail mounting foot, vertically orientated wiring and pressure connections, and a pushbutton zero function conveniently located on the front cover. The MLP2 offers two options for DIN Rail mounting; rear and side mount. The rear DIN rail mount is integrated into the enclosure. The side mount adapter is included with the package, and can easily be attached. The side mount offers a much thinner profile for higher density panels. The MLP2 incorporates a high accuracy, piezoresistive, silicon sensing element which senses differential pressure and provides a linear 4 to 20 mA or DC voltage output equal to the specified pressure range. This technology reduces warmup shift while also reducing the effect of package stress for increased long term stability. In addition, the unit contains a de-pluggable terminal block that can be removed for ease of installation. This unit must be ordered with a single uni or bi-directional pressure range and output signal from +/- 0.1 of water column to a maximum pressure of +/- 40 of water column depending on your application. All MLP2 Series pressure transmitters are calibrated using NIST Certified equipment. Optional 3 or 5 point NIST Certificates are available and must be specified when placing your order.

Applications: Building and Duct Static Pressure, Filter Monitoring, Air Flow Measurement, Process Control, Roof Top Units, Air Handlers, Clean Rooms, Isolation Rooms, Data Centers

The MLP2 Series Low Differential Pressure Transmitters are covered by ACIs Five (5) Year Limited Warranty. The warranty can be found in the front of ACIs Sensors & Transmitters catalog, as well as on ACIs web site, workaci.com.

Specifications

Item Number A/MLP2-010-W-U-A-B-0P
Brand ACI
Direction Unidirectional
Pressure Output Signal 0-5 VDC
Pressure Range 0-10" w.c.
Pressure Sensor Type Differential
Sensor Pressure