LC2D40G7 | TeSys D Contactor, 3-Poles (3 NO), 40A, 120V AC Coil, Reversing | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: LC2D40G7

Web Price:

$797.85
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

LC2D40G7 | TeSys D Contactor, 3-Poles (3 NO), 40A, 120V AC Coil, Reversing | Square D by Schneider Electric

Square D | LC2D40G7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC2D40G7

Documents and manuals

Square D LC2D40G7 Documents

Overview

Details for LC2D40G7

TeSys D Contactor, 3-Poles (3 NO), 40A, 120V AC Coil, Reversing

TeSys Deca reversing contactor, 3 poles (3NO),for motor control applications 40A/440V,AC-3 18.5kW@400V. Pre-wired power connections, with mechanical interlock,without electrical interlocking. It provides a 120V 60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Compact (90mm width), with DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN), Green Premium compliant (RoHS/REACh).

Specifications

Range of product
TeSys Deca
Product or component type
Reversing contactor
device short name
LC2D
contactor application
Motor control
Utilisation category
AC-4
AC-2
AC-3
control circuit type
AC
Coil type
Standard
Poles description
3P
Pole contact composition
3 NO
[Ie] rated operational current
Power circuit: 40 A AC AC-3 (at <60 °C)
Motor power kW
11 kW at 220...240 V AC 50/60 Hz
22 kW at 415 V AC 50/60 Hz
22 kW at 440 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 660...690 V AC 50/60 Hz
18.5 kW at 380...400 V AC 50/60 Hz
[Uc] control circuit voltage
120 V AC 60 Hz
Connections - terminals
Control circuit: 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: 1 cable(s) 1…4 mm²solid without cable end
Control circuit: 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: 2 cable(s) 1…4 mm²solid without cable end
Power circuit: 1 cable(s) 1…35 mm²flexible with cable end
Power circuit: 1 cable(s) 1…35 mm²flexible without cable end
Power circuit: 1 cable(s) 1…35 mm²solid without cable end
Power circuit: 2 cable(s) 1…25 mm²flexible with cable end
Power circuit: 2 cable(s) 1…25 mm²flexible without cable end
Power circuit: 2 cable(s) 1…25 mm²solid without cable end
Power circuit: 2 cable(s) 1…35 mm²flexible with cable end
Power circuit: 2 cable(s) 1…35 mm²flexible without cable end
Power circuit: 2 cable(s) 1…35 mm²solid without cable end
Assembly style
Ready assembled
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Protective cover
With
Auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
auxiliary contact composition
1 NO + 1 NC
Interlocking type
Mechanical
Control circuit voltage limits
Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)
Operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)
Operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
[Ui] rated insulation voltage
Control circuit: 600 V CSA certified
Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
Overvoltage category
III
Mounting support
Rail
Plate
Flame retardance
V1 conforming to UL 94
Tightening torque
Control circuit: 1.7 N.m - cable 1…2.5 mm² - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - cable 1…2.5 mm² - with screwdriver Philips No 2
Control circuit: 1.7 N.m - cable 1…4 mm² - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - cable 1…4 mm² - with screwdriver Philips No 2
Power circuit: 5 N.m - cable 1…25 mm² hexagonal screw head
Power circuit: 8 N.m - cable 1…35 mm² hexagonal screw head
[Ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz
[Ith] conventional free air thermal current
10 A (at 60 °C) for control circuit
60 A (at 60 °C) for power circuit
Irms rated making capacity
140 A AC for control circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
800 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
- Ith 60 A 50 Hz for power circuit
Power dissipation per pole
2.4 W AC-3 - Ith 60 A
Inrush power in VA
200 VA cos phi 0.75 (at 20 °C)
220 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA
20 VA 50 Hz cos phi 0.3 (at 20 °C)
22 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
26 VA 60 Hz cos phi 0.3 (at 20 °C)
Operating time
12...26 ms closing
4...19 ms opening
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability
6000000 cycles
Maximum operating rate
3600 cyc/h 60 °C
Minimum switching current
5 mA for control circuit
Minimum switching voltage
17 V for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
Insulation resistance
> 10 MOhm for control circuit
Height
132 mm
Width
165 mm
Depth
142 mm
Net weight
2.4 kg
Standards
CSA C22.2 No 14
IEC 60947-4-1
EN 60947-4-1
UL 508
IEC 60947-5-1
EN 60947-5-1
product certifications
GOST
CCC
GL
LROS (Lloyds register of shipping)
BV
UL
DNV
RINA
CSA
IP degree of protection
IP2X conforming to IEC 60529
IP2X conforming to VDE 0106
Protective treatment
TH (pollution degree 3) conforming to IEC 60068
Ambient air temperature for operation
-5…60 °C
Ambient air temperature for storage
-60…80 °C
Permissible ambient air temperature around the device
-40…70 °C at Uc
Operating altitude
3000 m without derating
Fire resistance
850 °C conforming to IEC 60695-2-1
Shock resistance
10 gn contactor closed
8 gn contactor opened
Vibration resistance
2 gn 5…300 Hz contactor opened
4 gn 5…300 Hz contactor closed
Heat dissipation
6…10 W at 50/60 Hz for control circuit
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
17.0 cm
Package 1 Width
18.0 cm
Package 1 Length
24.8 cm
Package 1 Weight
3.285 kg
Warranty
18 months

Reviews