LC1F185U7 | TeSys F Contactor, 3-Poles (3 NO), 185A, 240V AC Coil, Non-Reversing | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: LC1F185U7
Get a Quote
Availability: Get a Quote
The product is not cancelable or returnable unless found defective
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

LC1F185U7 | TeSys F Contactor, 3-Poles (3 NO), 185A, 240V AC Coil, Non-Reversing | Square D by Schneider Electric

Square D | LC1F185U7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1F185U7

Documents and manuals

Square D LC1F185U7 Documents

Overview

Details for LC1F185U7

TeSys F Contactor, 3-Poles (3 NO), 185A, 240V AC Coil, Non-Reversing

TeSys D Contactor
  • Number of Poles: 3-Poles
  • Pole Contact Composition: 3 NO
  • Rated Operational Current: 185A
  • Control Circuit Voltage: 240V AC 40-400 Hz
  • Non-Reversing
  • Specifications

    range
    TeSys
    Range of Product
    TeSys F
    Product or Component Type
    Contactor
    device short name
    LC1F
    contactor application
    Resistive load;Motor control
    utilisation category
    AC-4;AC-1;AC-3
    poles description
    3P
    [Ue] rated operational voltage
    <= 460 V DC;<= 690 V AC 50/60 Hz
    [Uc] control circuit voltage
    240 V AC 40...400 Hz
    [Ie] rated operational current
    275 A 104 °F (40 °C)) <= 440 V AC-1;185 A 131 °F (55 °C)) <= 440 V AC-3
    [Uimp] rated impulse withstand voltage
    8 kV
    [Ith] conventional free air thermal current
    275 A 104 °F (40 °C)
    rated breaking capacity
    1480 A IEC 60947-4-1
    [Icw] rated short-time withstand current
    1500 A 104 °F (40 °C) - 10 s;920 A 104 °F (40 °C) - 30 s;740 A 104 °F (40 °C) - 1 min;500 A 104 °F (40 °C) - 3 min;400 A 104 °F (40 °C) - 10 min
    associated fuse rating
    200 A aM <= 440 V;315 A gG <= 440 V
    average impedance
    0.33 mOhm - Ith 275 A 50 Hz
    [Ui] rated insulation voltage
    1000 V IEC 60947-4-1;1500 V VDE 0110 group C
    power dissipation per pole
    12 W AC-3;25 W AC-1
    overvoltage category
    III
    power pole contact composition
    3 NO
    motor power kW
    90 kW 380...400 V AC 50/60 Hz AC-3);100 kW 415 V AC 50/60 Hz AC-3);100 kW 440 V AC 50/60 Hz AC-3);110 kW 500 V AC 50/60 Hz AC-3);110 kW 660...690 V AC 50/60 Hz AC-3);55 kW 220...230 V AC 50/60 Hz AC-3);33 kW 400 V AC 50/60 Hz AC-4)
    control circuit voltage limits
    Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C));Drop-out 0.2...0.55 Uc 40...400 Hz 131 °F (55 °C))
    mechanical durability
    10 Mcycles
    inrush power in VA
    1070 VA;40...400 Hz 0.9 68 °F (20 °C))
    hold-in power consumption in VA
    9.9 VA;40...400 Hz 0.9 68 °F (20 °C))
    maximum operating rate
    2400 cyc/h 131 °F (55 °C)
    operating time
    35 ms closing at Uc);130 ms opening at Uc)
    connections - terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end;Power circuit bar 2 25 x 3 mm;Power circuit lugs-ring terminals 1 0.23 in² (150 mm²);Power circuit connector 1 0.23 in² (150 mm²);Power circuit bolted connection
    tightening torque
    Control circuit 10.62 lbf.in (1.2 N.m);Power circuit 159.31 lbf.in (18 N.m)
    Mounting Support
    Plate
    heat dissipation
    8…9.8 W
    motor power range
    30…50 kW 200…240 V 3 phase;55…100 kW 200…240 V 3 phase;55…100 kW 380…440 V 3 phase;55…100 kW 480…500 V 3 phase;110…220 kW 480…500 V 3 phase
    motor starter type
    Direct on-line contactor
    contactor coil voltage
    240 V AC standard
    Standards
    IEC 60947-1;JIS C8201-4-1;EN 60947-1;IEC 60947-4-1;EN 60947-4-1
    Product Certifications
    LROS (Lloyds register of shipping);UL;CSA;BV;CB;DNV;RMRoS;RINA;ABS;UKCA
    compatibility code
    LC1F
    control circuit type
    AC 40...400 Hz
    IP degree of protection
    IP2x front face with shrouds IEC 60529;IP2x front face with shrouds VDE 0106
    protective treatment
    TH
    Ambient air temperature for operation
    23…131 °F (-5…55 °C)
    Ambient Air Temperature for Storage
    -76…176 °F (-60…80 °C)
    permissible ambient air temperature around the device
    -40…158 °F (-40…70 °C)
    Height
    6.85 in (174 mm)
    Width
    6.63 in (168.5 mm)
    Depth
    7.13 in (181 mm)
    operating altitude
    9842.52 ft (3000 m) without derating
    Net Weight
    10.25 lb(US) (4.65 kg)
    Category
    22336-CTR;F-LINE;AC;OPEN;NONREV
    Discount Schedule
    I12
    GTIN
    3389110351583
    Returnability
    Yes
    Country of origin
    CZ
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Height
    8.27 in (21.0 cm)
    Package 1 Width
    8.66 in (22.0 cm)
    Package 1 Length
    9.45 in (24.0 cm)
    Package 1 Weight
    10.58 lb(US) (4.8 kg)
    Warranty
    18 months

    Reviews

    People Also Searched
    LC1F185U7
    Square D LC1F185U7
    LC1F185U7 price
    Square D LC1F185U7 price